1,624 research outputs found

    Improved Discretization of the Full First-Order Magnetic Field Integral Equation

    Full text link
    The inaccuracy of the classical magnetic field integral equation (MFIE) is a long-studied problem. We investigate one of the potential approaches to solve the accuracy problem: higher-order discretization schemes. While these are able to offer increased accuracy, we demonstrate that the accuracy problem may still be present. We propose an advanced scheme based on a weak-form discretization of the identity operator which is able to improve the high-frequency MFIE accuracy considerably - without any significant increase in computational effort or complexity.Comment: 3 pages, 1 figure, accepted for the 15th European Conference on Antennas and Propagation 2021 (EuCAP

    Separation und Analyse von Polyethylen-Partikeln unterschiedlicher fixed-bearing Knieprothesendesigns aus dem Kniesimulator

    Get PDF
    In der Endoprothetik sind Abriebpartikel von Polyethylen-Inlays ursĂ€chlich fĂŒr aseptische Prothesenlockerungen und damit fĂŒr die Limitierung der „Standzeiten“ dieser Prothesen verantwortlich. In der HĂŒftgelenkendoprothetik finden zunehmend, im Gegensatz zur Knieendoprothetik, Inlays aus quervernetztem Polyethylen klinische Anwendung. Die ZurĂŒckhaltung beruht im Allgemeinen auf der Angst vor frĂŒhzeitigem Materialversagen bei nicht ausreichend evaluierten biomechanischen Testungen. Die Entwicklung dieser neuen Materialien war Anlass, drei bikondylĂ€re fixed-bearing KnieoberflĂ€chenersatzprothesen mit unterschiedlichen Polyethyleninlays in Simulatorversuchen zu testen. Bei zwei dieser Prothesen bestehen die dazugehörigen Inlays aus hochvernetztem Polyethylen (XPE X3ℱ vom Modell ScorpioÂź der Fa. Stryker und XPE Durasulℱ vom Modell Natural Knee IIÂź der Fa. Zimmer). Als Vergleich diente die Kniegelenkprothese Natural Knee IIÂź mit dem konventionellem Polyethyleninlay (PE GUR 1050) der Fa. Zimmer. Im Vorfeld waren diese Modelle bereits im Rahmen einer anderen Untersuchung mechanisch und tribologisch getestet worden. Die Separation und Analyse der Polyethylenpartikel hinsichtlich GrĂ¶ĂŸe, Morphologie und Anzahl waren Zielparameter dieser Arbeit. Diese Auswertung erscheint wesentlich vor dem Hintergrund, da in vorausgegangenen Studien gezeigt werden konnte, dass diese Parameter einen entscheidenden Einfluss auf das Ausmaß der biologischen Reaktion haben, welche letzten Endes in eine Osteolyse mĂŒndet, die dann die aseptische Prothesenlockerung nach sich zieht. SĂ€mtliche Untersuchungen wurden unter identischen Voraussetzungen durchgefĂŒhrt. Zur Erzeugung des Polyethylen-Abriebes dienten Kniesimulatoren vom Typ Stallforth/UngethĂŒm. Nach Separation der Partikel aus dem Testmedium der vorausgegangenen Simulatorversuche mit Hilfe der SĂ€uredigestion, wurden die separierten Abriebpartikel auf einem Nano-Porenfilter abfiltriert und nach einer Goldbeschichtung des Filters elektronenmikroskopisch untersucht. Von jedem Filter wurden 20 randomisierte, nicht ĂŒberlappende Bilder bei einer 5’000-10’000-fachen VergrĂ¶ĂŸerung angefertigt. Die gespeicherten Bilder wurden anschließend mit Hilfe einer Fotoanalysesoftware mit Graustufenerkennung digital ausgewertet und die Partikel nach GrĂ¶ĂŸe und Morphologieparametern kategorisiert. Die Partikelanzahl wurde nach einer eigens hierfĂŒr entwickelten Formel errechnet. Diese ermittelt sich aus dem hochgerechneten Volumen der Partikel und dem gravimetrischen/volumetrischen Abrieb des Inlays selbst. Das Partikelspektrum ergab bei allen drei Materialkombinationen rundliche, granulĂ€re und nur wenig fibrillĂ€re Partikel. Insgesamt zeigten die Abriebpartikel der XPE-Inlays X3ℱ und Durasulℱ einen gering höheren Anteil runder und granulĂ€rer Abriebpartikel im Vergleich zum herkömmlichen UHMWPE. Das PartikelgrĂ¶ĂŸenspektrum zeigte annĂ€hernd gleiche Werte fĂŒr alle drei Gruppen. Lediglich die Partikel beim XPE X3ℱ-Inlay waren im Nanometerbereich kleiner (p < 0,05). Eine Änderung der PartikelgrĂ¶ĂŸe und –Morphologie aller drei Gruppen wĂ€hrend der 5'000'000 Zyklen war ebenfalls im Nanometerbereich nachweisbar, jedoch ergaben sich keine deutlichen ErgebnisverĂ€nderungen ĂŒber den gesamten Zeitraum. Der grĂ¶ĂŸte Unterschied aller drei untersuchten Materialkombinationen ergab sich im Hinblick auf die Partikelanzahl der XPE- und UHMWPE -Inlays. So ergab sich fĂŒr Stryker X3ℱ eine Anzahl von 25,3 Mrd. Partikeln/Mio. Zyklen, fĂŒr Zimmer Durasulℱ 46 Mrd. und fĂŒr Zimmer GUR 1050 204,4 Mrd. Partikel. Die Ergebnisse dieser Arbeit zeigen, dass die Verwendung von XPE als Werkstoff bei Knieprotheseninlays zu geringfĂŒgig kleineren Partikeln, vor allem aber zu einer deutlichen Reduktion der Abriebpartikel fĂŒhrt. Im Hinblick auf die potentielle inflammatorische AktivitĂ€t könnten die Partikel beim Modell ScorpioÂź (Fa. Stryker) mit dem Inlay X3ℱ, aufgrund der stark reduzierten Partikelanzahl bei nur geringfĂŒgig kleineren Partikeln (im Nanometerbereich), zu einer erniedrigten biologischen AktivitĂ€t in vivo fĂŒhren. Die Abriebpartikel beim Modell Natural Knee IIÂź (Fa. Zimmer) mit dem Inlay Durasulℱ zeigten ebenfalls eine deutliche Reduktion der Partikelanzahl im Vergleich zum konventionellem UHMWPE-Inlay, ferner eine Ă€hnliche GrĂ¶ĂŸenverteilung der Abriebpartikel. Auch dies spricht insgesamt fĂŒr eine geringere biologische AktivitĂ€t der Abriebpartikel in vivo. Der Einsatz von „crosslinked Polyethylen“ in der Kniegelenkendoprothetik erscheint vor dem Hintergrund der durchgefĂŒhrten Partikelanalyse durchaus sinnvoll und erweckt Hoffnung auf reduzierte EntzĂŒndungsreaktionen aufgrund der deutlich reduzierten Partikelanzahl ohne wesentliche GrĂ¶ĂŸen- und FormĂ€nderungen der Partikel, und damit auf lĂ€ngere „Standzeiten“ dieser Prothesen. Es bedarf aber noch zusĂ€tzlicher Untersuchungen dieses Werkstoffes in vivo, um adĂ€quate Aussagen ĂŒber die biologische AktivitĂ€t der entstandenen Abriebpartikel treffen zu können

    Biologische AktivitÀt von Metallpartikeln und -Ionen in vivo

    Get PDF

    Spatial phase dislocations in femtosecond laser pulses

    Get PDF
    We show that spatial phase dislocations associated with optical vortices can be embedded in femtosecond laser beams by computer-generated holograms, provided that they are built in a setup compensating for the introduced spatial dispersion of the broad spectrum. We present analytical results describing two possible arrangements: a dispersionless 4 setup and a double-pass grating compressor. Experimental results on the generation of optical vortices in the output beam of a 20 fs Ti:sapphire laser and the proof-of-principle measurements with a broadband-tunable cw Ti:sapphire laser confirm our theoretical predictions.This research was partially supported by the National Science Fund (Bulgaria), under contract F-1303/2003, and the Australian Research Council

    “Saw-Tooth Sign” in upper airway disorders — a case report

    Get PDF
    Pomiar spirometryczny pętli przepƂyw−objętoƛć jest powszechnym badaniem umoĆŒliwiającym wykluczenie obturacyjnych chorĂłb ukƂadu oddechowego. Pętle przepƂyw−objętoƛć pokazują przepƂyw powietrza, odnosząc się do objętoƛci pƂuc podczas maksymalnego wdechu i maksymalnego wydechu. UwaĆŒa się, ĆŒe widoczne sporadycznie na pętlach przepƂyw-objętoƛć wahania przepƂywu, nazywane „zębami piƂy”, są spowodowane obturacyjnymi procesami zachodzącymi w gĂłrnych drogach oddechowych, związanymi z ich zapadaniem się. Obszernie opisane w związku z powstawaniem obturacyjnego bezdechu sennego, wahania przepƂywu są związane takĆŒe z innymi chorobami. UwaĆŒa się, ĆŒe objaw „zębĂłw piƂy” powstaje na skutek nagƂych zmian ciƛnienia wewnątrz ƛwiatƂa przewodu. Pętle przepƂyw−objętoƛć dostarczają istotnych informacji dotyczących wzorĂłw wentylacji, ponadto, mogą wskazywać na ukryte choroby gĂłrnych drĂłg oddechowych. W pracy opisano przypadek pacjenta, u ktĂłrego wystąpiƂ objaw „zębĂłw piƂy” na pętli przepƂyw−objętoƛć.Spirometry flow-volume loop measurement is the screening test of choice to rule out obstructive lung diseases. Flow oscillations occasionally seen on flow volume loops, referred to as a “saw-tooth” sign, are thought to be due to an upper airway obstructive processes associated with upper airway collapsibility. Widely described in obstructive sleep apnea syndrome, flow oscillations have also been linked to many other upper airway pathologies. The mechanism by which flow oscillations occur is centered on the inspiratory and expiratory flow of air. It has been theorized that the mechanism of flow oscillations result from rapid intermittent changes in driving pressure or airway resistance. Since visual inspection of the flow volume loop can reveal presence of flow oscillations clinicians should be aware of this phenomenon and the presence of flow loop oscillations should clue physicians to rule out upper airway pathology

    CORRELATION BETWEEN COMPUTER VISION SYNDROME AND UPPER LIMB DISORDERS AT WIDYA MANDALA CATHOLIC UNIVERSITY SURABAYA

    Get PDF
    Background: The world of technology that continues to develop, especially in computer, makes workers spend more time operating electronic devices. This can contribute to eye strain which is one of the most common symptoms of Computer Vision Syndrome (CVS). CVS may associated with musculoskeletal disorders, especially at upper extremities due to non-ergonomic body position, which can be referred to as Upper Limb Disorders (ULD). Therefore, CVS can affect the severity of ULD.Purpose: To explain correlation between CVS with ULD to students at Widya Mandala Catholic University Surabaya.Methods: Analytics observational was the type of this research and the research design was cross sectional study.Result: The groups of respondents who experienced CVS with the severity of ULD on a scale 0 (A): no pain; scale 1 (B): moderately painful; scale 2 (C): painful; scale 3 (D): very painful were found to be 34.3%, 25%, 2.3% and 0%. And the groups of respondents who did not experience CVS with the severity of ULD on a scale 0 (A), scale 1 (B), scale 2 (C), and scale 3 (D) were found to be 35.5%, 2.9%, 0%, and 0%. Results from Spearman test found that the p=0.000 so there’s a significant correlation between the two variables with a weak correlation coefficient (r=0,39).Conclussion: There was correlation between CVS and ULD with a weak correlation coefficient value in students at Widya Mandala Catholic University Surabay

    Phase Retrieval for Partially Coherent Observations

    Full text link
    Phase retrieval is in general a non-convex and non-linear task and the corresponding algorithms struggle with the issue of local minima. We consider the case where the measurement samples within typically very small and disconnected subsets are coherently linked to each other - which is a reasonable assumption for our objective of antenna measurements. Two classes of measurement setups are discussed which can provide this kind of extra information: multi-probe systems and holographic measurements with multiple reference signals. We propose several formulations of the corresponding phase retrieval problem. The simplest of these formulations poses a linear system of equations similar to an eigenvalue problem where a unique non-trivial null-space vector needs to be found. Accurate phase reconstruction for partially coherent observations is, thus, possible by a reliable solution process and with judgment of the solution quality. Under ideal, noise-free conditions, the required sampling density is less than two times the number of unknowns. Noise and other observation errors increase this value slightly. Simulations for Gaussian random matrices and for antenna measurement scenarios demonstrate that reliable phase reconstruction is possible with the presented approach.Comment: 12 pages, 14 figure

    Linear Phase Retrieval for Near-Field Measurements with Locally Known Phase Relations

    Full text link
    A linear and thus convex phase retrieval algorithm for the application in phaseless near-field far-field transformations is presented. The formulation exploits locally known phase relations among sets of measurement samples, which can in practice be acquired with multi-channel receivers. Due to the linearity of the formulation, a reliable phaseless transformation is achieved, which completely avoids the problem of local minima - the Achilles heel of most existing phase retrieval techniques. Furthermore, the necessary number of measurements are kept close to that of fully-coherent antenna measurements. Comparisons with an already existing approach exploiting local phase relations demonstrate the accuracy and reliability for synthetic data.Comment: 5 pages, 3 figures, 1 table, submitted to the 15th European Conference on Antennas and Propagation 2021 (EuCAP

    In situ source levels of mulloway (Argyrosomus japonicus) calls.

    Get PDF
    Mulloway (Argyrosomus japonicus) in Mosman Bay, Western Australia produce three call categories associated with spawning behavior. The determination of call source levels and their contribution to overall recorded sound pressure levels is a significant step towards estimating numbers of calling fish within the detection range of a hydrophone. The source levels and ambient noise also provide significant information on the impacts anthropogenic activity may have on the detection of A. japonicus calls. An array of four hydrophones was deployed to record and locate individual fish from call arrival-time differences. Successive A. japonicus calls produced samples at various ranges between 1 and 100 m from one of the array hydrophones. The three-dimensional localization of calls, together with removal of ambient noise, allowed the determination of source levels for each call category using observed trends in propagation losses and interference. Mean source levels (at 1 m from the hydrophone) of the three call categories were calculated as 163 ± 16 dB re 1 ΌPa for Category 1 calls (short call of 2–5 pulses); 172 ± 4 dB re 1 ΌPa for Category 2 calls (long calls of 11–32 pulses); and 157 ± 5 dB re 1 ΌPa for Category 3 calls (series of successive calls of 1–4 pulses, increasing in call rate)

    THE RELATIONSHIP BETWEEN STRESS AND THE SLEEP QUALITY OF HEALTH WORKERS DURING THE COVID 19 PANDEMIC

    Get PDF
    Psychological stress is the body’s way to cope with stressors. We are not able to evade stressors. In fact, we need stressors to keep ourselves going. So stress to an extent is a good thing. It is harmful when it becomes a distress, in which it starts to affect our bodily function, including our sleep quality. Psychological stress will activate the body’s HPA-axis and the sympathetic pathway of the autonomic nervous system, releasing hormones such as Cortisol and Catecholamine. These hormones can cause the disturbance of sleep. The aim of this study is to find the relation between the level of stress and the sleep quality in healthcare workers during the COVID-19 pandemic. PSS (Perceived Stress Scale) was used to calculate the level of stress and PSQI (Pittsburgh Sleep Quality Index) was used to calculate sleep quality. In this study we found that the level of stress is related to sleep quality in healthcare workers during the COVID-19 pandemic. The relation is positive, significant (P = 0.002), and moderate (r = 0.4). To conclude, there is a relation between stress and sleep in healthcare workers during the COVID-19 pandemic
    • 

    corecore