56 research outputs found

    Design of a High Selectivity Filter for MRI Guided RF Hyperthermia Therapy

    Get PDF
    Hyperthermia devices have been integrated with MR scanners to exploit MR thermometry. Integrating two RF systems require the filtering of high-power RF heating signal from MR system for simultaneous heating and imaging. Currently, a filter that suppresses 100MHz and its harmonics is in use. Development of a MR-compatible hyperthermia applicator for head and neck requires a filter that can suppress also the 433.92MHz signal. A unique new filter which has high power handling, extremely high suppression, and selectivity has been designed that attenuates 100MHz and 433.92MHz signals with low insertion loss (&lt;0.25dB) at 63.89MHz. 0.14dB insertion loss at 63.89MHz, 112dB, 88dB and 93dB signal attenuation were achieved at 100MHz, 200MHz and 433.92MHz, respectively, with the new filter design using model of LM-500 cable. A proof of concept filter was constructed to validate the design. Our investigation shows that filter requirements can be satisfied, but high-power low-loss coaxial cables are necessary.</p

    MR thermometry accuracy and prospective imaging-based patient selection in MR-guided hyperthermia treatment for locally advanced cervical cancer

    Get PDF
    The efficacy of a hyperthermia treatment depends on the delivery of well-controlled heating; hence, accurate temperature monitoring is essential for ensuring effective treatment. For deep pelvic hyperthermia, there are no comprehensive and systematic reports on MR thermometry. Moreover, data inclusion generally lacks objective selection criteria leading to a high probability of bias when comparing results. Herein, we studied whether imaging-based data inclusion predicts accuracy and could serve as a tool for prospective patient selection. The accuracy of the MR thermometry in patients with locally advanced cervical cancer was benchmarked against intraluminal temperature. We found that gastrointestinal air motion at the start of the treatment, quantified by the Jaccard similarity coefficient, was a good predictor for MR thermometry accuracy. The results for the group that was selected for low gastrointestinal air motion improved compared to the results for all patients by 50% (accuracy), 26% (precision), and 80% (bias). We found an average MR thermometry accuracy of 2.0 °C when all patients were considered and 1.0 °C for the selected group. These results serve as the basis for comprehensive benchmarking of novel technologies. The Jaccard similarity coefficient also has good potential to prospectively determine in which patients the MR thermometry will be valuable.</p

    Adapting temperature predictions to MR imaging in treatment position to improve simulation-guided hyperthermia for cervical cancer

    Get PDF
    Hyperthermia treatment consists of elevating the temperature of the tumor to increase the effectiveness of radiotherapy and chemotherapy. Hyperthermia treatment planning (HTP) is an important tool to optimize treatment quality using pre-treatment temperature predictions. The accuracy of these predictions depends on modeling uncertainties such as tissue properties and positioning. In this study, we evaluated if HTP accuracy improves when the patient is imaged inside the applicator at the start of treatment. Because perfusion is a major uncertainty source, the importance of accurate treatment position and anatomy was evaluated using different perfusion values. Volunteers were scanned using MR imaging without (&amp;#x201C;planning setup&amp;#x201D;) and with the MR-compatible hyperthermia device (&amp;#x201C;treatment setup&amp;#x201D;). Temperature-based quality indicators were used to assess the differences between the standard, apparent and the optimized hyperthermia dose. We conclude that pre-treatment imaging can improve HTP predictions accuracy but also, that tissue perfusion modelling is crucial if temperature-based optimization is applied.</p

    Assessment of the thermal tissue models for the head and neck hyperthermia treatment planning

    Get PDF
    Purpose: To compare different thermal tissue models for head and neck hyperthermia treatment planning, and to assess the results using predicted and measured applied power data from clinical treatments. Methods: Three commonly used temperature models from literature were analysed: “constant baseline”, “constant thermal stress” and “temperature dependent”. Power and phase data of 93 treatments of 20 head and neck patients treated with the HYPERcollar3D applicator were used. The impact on predicted median temperature T50 inside the target region was analysed with maximum allowed temperature of 44 °C in healthy tissue. The robustness of predicted T50 for the three models against the influence of blood perfusion, thermal conductivity and the assumed hotspot temperature level was analysed. Results: We found an average predicted T50 of 41.0 ± 1.3 °C (constant baseline model), 39.9 ± 1.1 °C (constant thermal stress model) and 41.7 ± 1.1 °C (temperature dependent model). The constant thermal stress model resulted in the best agreement between the predicted power (P = 132.7 ± 45.9 W) and the average power measured during the hyperthermia treatments (P = 129.1 ± 83.0 W). Conclusion: The temperature dependent model predicts an unrealistically high T50. The power values for the constant thermal stress model, after scaling simulated maximum temperatures to 44 °C, matched best to the average measured powers. We consider this model to be the most appropriate for temperature predictions using the HYPERcollar3D applicator, however further studies are necessary for developing of robust temperature model for tissues during heat stress.</p

    An MR-compatible antenna and application in a murine superficial hyperthermia applicator

    Get PDF
    In this work, a novel magnetic resonance (MR)-compatible microwave antenna was designed and validated in a small animal superficial hyperthermia applicator. The antenna operates at 2.45 GHz and matching is made robust against production and setup inaccuracies. To validate our theoretical concept, a prototype of the applicator was manufactured and tested for its properties concerning input reflection, sensitivity for setup inaccuracies, environment temperature stability and MR-compatibility. The experiments show that the applicator indeed fulfils the requirements for MR-guided hyperthermia investigation in small animals: it creates a small heating focus (&lt;1 cm 3 ), has a stable and reliable performance (S 11 &lt; −15 dB) for all working conditions and is MR-compatible. </p

    Thermal dosimetry for bladder hyperthermia treatment. An overview.

    Get PDF
    The urinary bladder is a fluid-filled organ. This makes, on the one hand, the internal surface of the bladder wall relatively easy to heat and ensures in most cases a relatively homogeneous temperature distribution; on the other hand the variable volume, organ motion, and moving fluid cause artefacts for most non-invasive thermometry methods, and require additional efforts in planning accurate thermal treatment of bladder cancer. We give an overview of the thermometry methods currently used and investigated for hyperthermia treatments of bladder cancer, and discuss their advantages and disadvantages within the context of the specific disease (muscle-invasive or non-muscle-invasive bladder cancer) and the heating technique used. The role of treatment simulation to determine the thermal dose delivered is also discussed. Generally speaking, invasive measurement methods are more accurate than non-invasive methods, but provide more limited spatial information; therefore, a combination of both is desirable, preferably supplemented by simulations. Current efforts at research and clinical centres continue to improve non-invasive thermometry methods and the reliability of treatment planning and control software. Due to the challenges in measuring temperature across the non-stationary bladder wall and surrounding tissues, more research is needed to increase our knowledge about the penetration depth and typical heating pattern of the various hyperthermia devices, in order to further improve treatments. The ability to better determine the delivered thermal dose will enable clinicians to investigate the optimal treatment parameters, and consequentially, to give better controlled, thus even more reliable and effective, thermal treatments

    Versatile quadrature antenna for precise control of large electron spin ensembles in diamond

    Full text link
    We present an easily reproducible inexpensive microwave antenna that can generate a strong and homogeneous magnetic field of arbitrary polarization, which enables fast and coherent control of electron spins over a large volume. Unlike preceding works, we present a resonant antenna that maintains its resonant behaviour regardless of the proximity of other experimental hardware components. This robustness is crucial as it enables, amongst others, using microscope objectives with short working distances to perform wide field imaging/sensing with bulk diamonds. The antenna generates a magnetic field strength of 22.3 A/m for 1 W total driving power, which doubles the power efficiency compared with previously reported patch antenna designs. The magnetic field homogeneity in a volume of 0.3mm30.3 \text{mm}^3, 0.5mm30.5 \text{mm}^3 and 1mm31 \text{mm}^3 is within 6\%, 8\% and 13\%, respectively. The antenna has a full width at half maximum bandwidth of \sim160 MHz and its resonant frequency can be tuned over a 400 MHz range via four capacitors or varactors. The antenna has been tested and found to remain within safe handling temperatures during continuous-wave operation at 8 W. The files required to reproduce this antenna, which can be built on a standard and affordable double sided PCB, are provided open-source. This work facilitates a robust and versatile piece of instrumentation, being particularly appealing for applications such as high sensitivity magnetometry and wide field imaging/sensing with Nitrogen Vacancy centers

    Quantitative, Multi-institutional Evaluation of MR Thermometry Accuracy for Deep-Pelvic MR-Hyperthermia Systems Operating in Multi-vendor MR-systems Using a New Anthropomorphic Phantom

    Get PDF
    Clinical outcome of hyperthermia depends on the achieved target temperature, therefore target conformal heating is essential. Currently, invasive temperature probe measurements are the gold standard for temperature monitoring, however, they only provide limited sparse data. In contrast, magnetic resonance thermometry (MRT) provides unique capabilities to non-invasively measure the 3D-temperature. This study investigates MRT accuracy for MR-hyperthermia hybrid systems located at five European institutions while heating a centric or eccentric target in anthropomorphic phantoms with pelvic and spine structures. Scatter plots, root mean square error (RMSE) and Bland–Altman analysis were used to quantify accuracy of MRT compared to high resistance thermistor probe measurements. For all institutions, a linear relation between MRT and thermistor probes measurements was found with R2 (mean ± standard deviation) of 0.97 ± 0.03 and 0.97 ± 0.02, respectively for centric and eccentric heating targets. The RMSE was found to be 0.52 ± 0.31 °C and 0.30 ± 0.20 °C, respectively. The Bland-Altman evaluation showed a mean difference of 0.46 ± 0.20 °C and 0.13 ± 0.08 °C, respectively. This first multi-institutional evaluation of MR-hyperthermia hybrid systems indicates comparable device performance and good agreement between MRT and thermistor probes measurements. This forms the basis to standardize treatments in multi-institution studies of MR-guided hyperthermia and to elucidate thermal dose-effect relations

    Introduction to computational modeling in hyperthermia

    Get PDF
    Over the past two decades, computational modeling has gained a prominent role in hyperthermia research and its role for guiding treatments is expanding. Computational modeling serves e.g., to design new applicators, in silico testing of novel treatment approaches and providing insight in treatment safety. Hyperthermia treatment modeling and optimization (HTM&O), also known as hyperthermia treatment planning (HTP), is the process in which the multidisciplinary hyperthermia team defines the optimal treatment plan for a specific cancer patient using the available hyperthermia treatment resources. HTM&O includes computational modeling approaches for pretreatment HTP and online treatment guidance

    The Required Patient Modeling Realism in Radiofrequency Heating Simulation Studies

    No full text
    Clinical effectiveness of hyperthermia would benefit from a more controlled and target conformal heating of the tumor. Over the years, dosimetry using electromagnetic simulators has become a potent tool to study improvements in the application of hyperthermia. Literature suggests that simulation accuracy is dependent on the realism of the patient models. In this work, we compare the results for a detailed head and neck patient model to those for models with an approximated shape, a reduced tissue number and/or a spherical target volume. Our comparison shows a relative difference above 25% in the administered power absorption pattern. This large difference calls upon 1) follow-up research to establish the true impact using a larger set of patient models and 2) the development of a reference set of patient models to facilitate benchmarking of novel devices, methods and treatment approaches
    corecore