    Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: Patent ductus arteriosus and vascular rings

    Get PDF
    Abstract Background Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT) was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography. Results Electrocardiography (ECG)-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol. Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats. Conclusions Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional information can be of help with regard to improved diagnoses of thoracic anomalies and the planning of surgical interventions.</p

    Multi-body simulation of a canine hind limb: model development, experimental validation and calculation of ground reaction forces

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Among other causes the long-term result of hip prostheses in dogs is determined by aseptic loosening. A prevention of prosthesis complications can be achieved by an optimization of the tribological system which finally results in improved implant duration. In this context a computerized model for the calculation of hip joint loadings during different motions would be of benefit. In a first step in the development of such an inverse dynamic multi-body simulation (MBS-) model we here present the setup of a canine hind limb model applicable for the calculation of ground reaction forces.</p> <p>Methods</p> <p>The anatomical geometries of the MBS-model have been established using computer tomography- (CT-) and magnetic resonance imaging- (MRI-) data. The CT-data were collected from the pelvis, femora, tibiae and pads of a mixed-breed adult dog. Geometric information about 22 muscles of the pelvic extremity of 4 mixed-breed adult dogs was determined using MRI. Kinematic and kinetic data obtained by motion analysis of a clinically healthy dog during a gait cycle (1 m/s) on an instrumented treadmill were used to drive the model in the multi-body simulation.</p> <p>Results and Discussion</p> <p>As a result the vertical ground reaction forces (z-direction) calculated by the MBS-system show a maximum deviation of 1.75%BW for the left and 4.65%BW for the right hind limb from the treadmill measurements. The calculated peak ground reaction forces in z- and y-direction were found to be comparable to the treadmill measurements, whereas the curve characteristics of the forces in y-direction were not in complete alignment.</p> <p>Conclusion</p> <p>In conclusion, it could be demonstrated that the developed MBS-model is suitable for simulating ground reaction forces of dogs during walking. In forthcoming investigations the model will be developed further for the calculation of forces and moments acting on the hip joint during different movements, which can be of help in context with the <it>in silico </it>development and testing of hip prostheses.</p

    Impact of body weight and sex in selected dog breeds on the canine adrenal gland dimensions measured by computed tomographic imaging

    No full text
    Abstract Background The present study aimed to investigate possible influences of body weight and sex on adrenal gland size in endocrinologically healthy dogs. Possible factors influencing the adrenal size are discussed in relation to a universal upper reference value from the literature of 7.4 mm as the thickness in the caudal pole of the adrenal gland. The adrenal size was measured by computed tomography (CT) from 66 normal dogs of six different breeds (Labrador Retriever (n = 16), German Shepherd (n = 10), Boxer (n = 8), Beagle (n = 14), Dachshund (n = 6) and Jack Russell Terrier (n = 12); male n = 38 (thereof neutered n = 23), female n = 28 (thereof neutered n = 17)) based on volume quantification and linear measurements using the data processing software Amira. For interbreed comparability, a ratio consisting of the third root of adrenal volume to aortic diameter (Ratio volume-aorta, RVA) was introduced. Additionally, breed-related attenuation values in contrast-enhanced CT data sets were measured. Results The measured volumes ranged from 0.34 to 1.93 cm3 for the right and from 0.39 to 2.23 cm3 for the left adrenal gland. The present study was able to demonstrate a body weight effect on the adrenal volume as well as on length and height. In terms of adrenal size, no significant differences between male and female, nor between intact and neutered dogs were obtained due to the RVA. In addition, for the weight classes, a breed independent threshold for dogs less (left 1.4; right gland 1.5) or more than 20 kg body weight (left 1.1; right gland 1.2) based on RVA was defined. Breed-related significant differences with respect to attenuation were determined only for the left adrenal gland, with lower attenuation values in large dog breeds. Conclusion The present study points out the importance of weight-related data when assessing CT data of the canine adrenal gland regarding volume, size and attenuation. The use of a universal reference value for the assessment of adrenal size appears unsuitable considering weight-related volume and linear measurements. Sex seems not to affect adrenal gland size

    Quantification of right ventricular volume in dogs: a comparative study between three-dimensional echocardiography and computed tomography with the reference method magnetic resonance imaging

    Get PDF
    BACKGROUND: Right ventricular (RV) volume and function are important diagnostic and prognostic factors in dogs with primary or secondary right-sided heart failure. The complex shape of the right ventricle and its retrosternal position make the quantification of its volume difficult. For that reason, only few studies exist, which deal with the determination of RV volume parameters. In human medicine cardiac magnetic resonance imaging (CMRI) is considered to be the reference technique for RV volumetric measurement (Nat Rev Cardiol 7(10):551-563, 2010), but cardiac computed tomography (CCT) and three-dimensional echocardiography (3DE) are other non-invasive methods feasible for RV volume quantification. The purpose of this study was the comparison of 3DE and CCT with CMRI, the gold standard for RV volumetric quantification. RESULTS: 3DE showed significant lower and CCT significant higher right ventricular volumes than CMRI. Both techniques showed very good correlations (R > 0.8) with CMRI for the volumetric parameters end-diastolic volume (EDV) and end-systolic volume (ESV). Ejection fraction (EF) and stroke volume (SV) were not different when considering CCT and CMRI, whereas 3DE showed a significant higher EF and lower SV than CMRI. The 3DE values showed excellent intra-observer variability (<3%) and still acceptable inter-observer variability (<13%). CONCLUSION: CCT provides an accurate image quality of the right ventricle with comparable results to the reference method CMRI. CCT overestimates the RV volumes; therefore, it is not an interchangeable method, having the disadvantage as well of needing general anaesthesia. 3DE underestimated the RV-Volumes, which could be explained by the worse image resolution. The excellent correlation between the methods indicates a close relationship between 3DE and CMRI although not directly comparable. 3DE is a promising technique for RV volumetric quantification, but further studies in awake dogs and dogs with heart disease are necessary to evaluate its usefulness in veterinary cardiology

    Experimental set-up used in the current study.

    No full text
    <p>The dogs walked and trotted at their preferred speed on the instrumented four-belt treadmill, which allowed for the synchronous collection of single limb forces before and after a distal load-bearing lameness was induced in the right forelimb (see inset).</p

    Symmetry indices for mean (M) and peak (P) as well as the sum (S) of the braking (Fy-) and propulsive (Fy+) forces for the sound condition and when lameness was induced.

    No full text
    <p>Prefect symmetry is represented by SI = 0. Negative values indicate the respective parameter was greater for the contra- than the ipsilateral limb; positive values indicate a greater value for the ipsi- than the contralateral side. Significant differences between sound and lame conditions at * p<0.05; n.s. = not significant.</p