54 research outputs found

    The amidine based colorimetric sensor for Fe³⁺, Fe²⁺, and Cu²⁺ in aqueous medium

    Get PDF
    An amidine based chemosensor AM-1 was synthesized and characterized by various spectroscopic (FT-IR, 1H-NMR and mass) data and elemental analyses. Sensor AM-1 exhibited high selectivity and sensitivity towards Fe³⁺, Fe²⁺ and Cu²⁺ in the presence of other surveyed ions (such as Sr²⁺, Cr³⁺, Co²⁺, Ni²⁺, Zn²⁺, Ag⁺, Al³⁺, Ba²⁺, Ca²⁺, Cd²⁺, Cs⁺, Hg²⁺, K⁺, Li⁺, Mg²⁺, Mn²⁺, Na⁺ and Pb²⁺) with a distinct naked-eye detectable color change and a shift in the absorption band. Moreover, the emission of AM-1 was quenched selectively only in the presence of Fe³⁺

    A novel fluorescent "turn-on" chemosensor for nanomolar detection of Fe(III) from aqueous solution and its application in living cells imaging

    Get PDF
    An electronically active and spectral sensitive fluorescent “turn-on” chemosensor (BTP-1) based on the benzo-thiazolo-pyrimidine unit was designed and synthesized for the highly selective and sensitive detection of Fe³⁺ from aqueous medium. With Fe³⁺, the sensor BTP-1 showed a remarkable fluorescence enhancement at 554 nm (λex=314 nm) due to the inhibition of photo-induced electron transfer. The sensor formed a host-guest complex in 1:1 stoichiometry with the detection limit down to 0.74 nM. Further, the sensor was successfully utilized for the qualitative and quantitative intracellular detection of Fe³⁺ in two liver cell lines i.e., HepG2 cells (human hepatocellular liver carcinoma cell line) and HL-7701 cells (human normal liver cell line) by a confocal imaging technique

    A uracil nitroso amine based colorimetric sensor for the detection of Cu²⁺ ions from aqueous environment and its practical applications

    Get PDF
    A simple uracil nitroso amine based colorimetric chemosensor (UNA-1) has been synthesized and screened for its cation recognition ability. Sensor UNA-1 exhibited a high sensitivity and selectivity towards Cu²⁺ ions in aqueous medium in the presence of a wide range of other competing cations (Ag⁺, Al³⁺, Ba²⁺+, Ca²⁺, Cd²⁺, Co²⁺, Cr³⁺, Cs⁺, Fe²⁺, Fe³⁺, Li⁺, Mg²⁺, Mn²⁺, Na⁺, Ni²⁺, Pb²⁺, Zn²⁺, Hg²⁺ and Sr²⁺). With Cu²⁺, the sensor UNA-1 gave a distinct color change from colorless to dark yellow by forming a complex of 1:1 stoichiometry. Furthermore, sensor UNA-1 was successfully utilized in the preparation of test strips and supported silica for the detection of Cu²⁺ ions from aqueous environment

    A low-cost miniature immunosensor for haemoglobin as a device for the future detection of gastrointestinal bleeding

    Get PDF
    Gastrointestinal bleeding (GIB) is a serious medical condition, which requires immediate attention to establish the cause of the bleeding. Here, we present the development of a miniaturised electrochemical impedance spectroscopy (EIS) device for the detection of GIB. The device performs EIS measurements up to 100 kHz. Following the development of an immunosensor for haemoglobin (Hb) on screen printed electrodes, the EIS device was used for detecting Hb as an early indication of bleeding. The sensor was able to detect Hb in a redox solution in a linear range between 5 μg mL−1 and 60 μg mL−1, with a limit of detection of 13.3 μg mL−1. It was also possible to detect Hb in simulated intestinal fluid, without the need for a redox solution, within a range of 10 μg mL−1 to 10 mg mL−1 with a limit of detection of 2.31 mg mL−1. The miniature EIS device developed in this work is inexpensive, with an estimated cost per unit of £30, and has shown a comparable performance to existing commercial tools, demonstrating its potential to be used in the future as an ingestible sensor to detect GIB. All these measurements were carried out in a purpose built flow cell with supporting hardware electronics outside the cell. Integration of the hardware and the sensing electrodes was demonstrated in pill form. This pill after integration sampling fluidics has potential to be used in detecting gastrointestinal bleeding

    Chemosensor for micro to nano-molar detection of Ag+ and Hg2+ ions in pure aqueous media and its applications in cell imaging

    Get PDF
    The pyridine substituted thiourea derivative PTB-1 was synthesized and characterized by spectroscopic techniques as well as by single crystal X-ray crystallography. The metal ion sensing ability of PTB-1 was explored by various experimental (naked-eye, UV-Vis, fluorescence, mass spectrometry and 1H NMR spectroscopy) and theoretical (B3LYP/6-31G**/LANL2DZ) methods. PTB-1 exhibited a highly selective naked-eye detectable color change from colorless to dark brown and UV-Vis spectral changes for the detection of Ag+ with a detection limit of 3.67 µM in aqueous medium. The detection of Ag+ ions was achieved by test paper strip and supported silica methods. In contrast, PTB-1 exhibited a 23-fold enhanced emission at 420 nm in the presence of Hg2+ ions with a nano-molar detection limit of 0.69 nM. Finally, the sensor PTB-1 was applied successfully for the intracellular detection of Hg2+ ions in a HepG2 liver cell line, which was monitored by use of confocal imaging techniques

    Micromolar metabolite measurement in an electronically multiplexed format

    Get PDF
    The detection of metabolites such as choline in blood are important in clinical care for patients with cancer and cardiovascular disease. Choline is only present in human blood at low concentrations hence accurate measurement in an affordable point-of-care format is extremely challenging. Integration of microfluidics on to complementary metal-oxide semiconductor (CMOS) technology has the potential to enable advanced sensing technologies with extremely low limit of detection that are well suited to multiple clinical metabolite measurements. Although CMOS and microfluidics are individually mature technologies, their integration has presented challenges that we overcome in a novel, cost-effective, single-step process. To demonstrate the process, we present the microfluidic integration of a metabolomics-on-CMOS point-of-care platform with four capillary microfluidic channels on top of a CMOS optical sensor array. The fabricated device was characterised to verify the required structural profile, mechanical strength, optical spectra, and fluid flow. As a proof of concept, we used the device for the in-vitro quantification of choline in human blood plasma with a limit of detection of 3.2 M and a resolution of 1.6 M

    The Multicorder: A Handheld Multimodal Metabolomics-on-CMOS Sensing Platform

    Get PDF
    The use of CMOS platforms in medical point-of-care applications, by integrating all steps from sample to data output, has the potential to reduce the diagnostic cost and the time from days to seconds. Here we present the `Multicorder' technology, a handheld versatile multimodal platform for rapid metabolites quantification. The current platform is composed of a cartridge, a reader and a graphic user interface. The sensing core of the cartridge is the CMOS chip which integrates a 16×16 array of multi-sensor elements. Each element is composed of two optical and one chemical sensor. The platform is therefore capable of performing multi-mode measurements: namely colorimetric, chemiluminescence, pH sensing and surface plasmon resonance. In addition to the reader that is employed for addressing, data digitization and transmission, a tablet computer performs data collection, visualization, analysis and storage. In this paper, we demonstrate colorimetric, chemiluminescence and pH sensing on the same platform by on-chip quantification of different metabolites in their physiological range. The platform we have developed has the potential to lead the way to a new generation of commercial devices in the footsteps of the current commercial glucometers for quick multi-metabolite quantification for both acute and chronic medicines

    Modified Cantilever Arrays Improve Sensitivity and Reproducibility of Nanomechanical Sensing in Living Cells

    Get PDF
    Mechanical signaling involved in molecular interactions lies at the heart of materials science and biological systems, but the mechanisms involved are poorly understood. Here we use nanomechanical sensors and intact human cells to provide unique insights into the signaling pathways of connectivity networks, which deliver the ability to probe cells to produce biologically relevant, quantifiable and reproducible signals. We quantify the mechanical signals from malignant cancer cells, with 10 cells per ml in 1000-fold excess of non-neoplastic human epithelial cells. Moreover, we demonstrate that a direct link between cells and molecules creates a continuous connectivity which acts like a percolating network to propagate mechanical forces over both short and long length-scales. The findings provide mechanistic insights into how cancer cells interact with one another and with their microenvironments, enabling them to invade the surrounding tissues. Further, with this system it is possible to understand how cancer clusters are able to co-ordinate their migration through narrow blood capillaries

    An integrated portable system for single chip simultaneous measurement of multiple disease associated metabolites

    Get PDF
    Metabolites, the small molecules that underpin life, can act as indicators of the physiological state of the body when their abundance varies, offering routes to diagnosis of many diseases. The ability to assay for multiple metabolites simultaneously will underpin a new generation of precision diagnostic tools. Here, we report the development of a handheld device based on complementary metal oxide semiconductor (CMOS) technology with multiple isolated micro-well reaction zones and integrated optical sensing allowing simultaneous enzyme-based assays of multiple metabolites (choline, xanthine, sarcosine and cholesterol) associated with multiple diseases. These metabolites were measured in clinically relevant concentration range with minimum concentrations measured: 25 μM for choline, 100 μM for xanthine, 1.25 μM for sarcosine and 50 μM for cholesterol. Linking the device to an Android-based user interface allows for quantification of metabolites in serum and urine within 2 min of applying samples to the device. The quantitative performance of the device was validated by comparison to accredited tests for cholesterol and glucose
    corecore