32 research outputs found

    Going Open in Afghanistan

    Get PDF
    Some findings from this impact study of Open Educational Resources (OER) are: using OER improved teachers’ lesson plans; OER gave teachers more current subject info; OER extended knowledge of the topic taught; OER helped initiate collaboration among students (and to a lesser extent among teachers); OER impacted teachers’ instructional techniques, pedagogy, and content knowledge. 48 participants engaged in discussion of accessibility and practices of Open Educational Resources in Parwan, Afghanistan. This presentation reviews the workshop study

    First clinical experience of high-power ablation of atrial fibrillation with a novel contact force-sensing gold-tip catheter

    Get PDF
    Background: Contact force (CF)-sensing catheters are commonly used in the field of radiofrequency (RF) ablation to treat atrial fibrillation (AF). Increasing ablation power (e.g., 50 W) has been suggested as a method to reduce procedure times whilst creating safe and lasting lesions. Methods: We report the first clinical evidence of a 50 W point-by-point RF ablation in 25 consecutive patients with symptomatic AF using a novel CF-sensing catheter with a gold tip (AlCath Force, BIOTRONIK). We collected and analyzed procedural and ablation parameters. The safety and efficacy of the catheter were evaluated. Results: Altogether, 985 RF lesions in 25 patients were created with a mean number of 39.4 +/- 16.3 lesions per patient. The total skin-to-skin procedure time was 116.1 +/- 35.1 min, and the mean total area dose product was 10.9 +/- 5.1 Gy*cm2. The mean RF time per procedure was 13.2 +/- 6.6 min. The mean RF time per lesion was 20.2 +/- 8.4 s. The mean CF was 15.7 +/- 7.6 g. We observed a mean force time integral of 274.7 +/- 11.1 gs (range: 53 to 496 gs). Acute procedural success, defined as entrance and exit block in all pulmonary veins, could be obtained in all cases. No procedure- or device-related serious adverse events were observed. No audible steam pops occurred. Optical inspection of the catheter after the procedure showed neither charring nor clotting. Conclusions: We provide the first evidence for the safety and efficacy of 50 W ablation using the AlCath Force gold-tip catheter. These data must be supported by a larger multi-center study

    Ventricular tachycardia (VT) storm after cryoballoon-based pulmonary vein isolation

    Get PDF
    Objective: Unusual clinical course. Background: Following catheter ablation of atrial fibrillation, increased incidence of ventricular arrhythmia has been observed. We report a case of sustained ventricular arrhythmia in a patient who underwent cryoballoon-based pulmonary vein isolation for symptomatic persistent atrial fibrillation. Case Report: A 57-year-old patient with dilated cardiomyopathy underwent CB-based pulmonary vein isolation for symptomatic persistent AF. On the day following an uneventful procedure, the patient for the first time experienced a sustained ventricular tachycardia that exacerbated into VT storm. Each arrhythmia was terminated by the ICD that had been implanted for primary prevention. Antiarrhythmic treatment with amiodarone was initiated immediately. The patient remained free from sustained ventricular arrhythmia during follow-up. Conclusions: After pulmonary vein isolation, physicians should be vigilant for ventricular arrhythmia. The influence of atrial autonomic innervation on ventricular electrophysiology is largely unknown

    Left atrial diverticulum - An unexpected finding in routine transesophageal echocardiography

    Get PDF
    We report a 55-year-old male patient with lone paroxysmal atrial fibrillation who underwent routine transesophageal echocardiography (TOE) at our institution. In a mid-esophageal 125 degrees three-chamber angulation, a distinct thinning of the left atrial (LA) wall was observed, forming a 7 x 4 mm canal with only a small membrane separating the LA from the pericardial space. Cardiac magnetic resonance imaging diagnosed a small LA diverticulum. To the best of our knowledge, this is the first manuscript describing detection of a small LA diverticulum via TOE

    Oxidative Stress and Inflammatory Modulation of Ca2+ Handling in Metabolic HFpEF-Related Left Atrial Cardiomyopathy

    Get PDF
    Metabolic syndrome-mediated heart failure with preserved ejection fraction (HFpEF) is commonly accompanied by left atrial (LA) cardiomyopathy, significantly affecting morbidity and mortality. We evaluate the role of reactive oxygen species (ROS) and intrinsic inflammation (TNF-α, IL-10) related to dysfunctional Ca2+ homeostasis of LA cardiomyocytes in a rat model of metabolic HFpEF. ZFS-1 obese rats showed features of HFpEF and atrial cardiomyopathy in vivo: increased left ventricular (LV) mass, E/e' and LA size and preserved LV ejection fraction. In vitro, LA cardiomyocytes exhibited more mitochondrial-fission (MitoTracker) and ROS-production (H2DCF). In wildtype (WT), pro-inflammatory TNF-α impaired cellular Ca2+ homeostasis, while anti-inflammatory IL-10 had no notable effect (confocal microscopy; Fluo-4). In HFpEF, TNF-α had no effect on Ca2+ homeostasis associated with decreased TNF-α receptor expression (western blot). In addition, IL-10 substantially improved Ca2+ release and reuptake, while IL-10 receptor-1 expression was unaltered. Oxidative stress in metabolic syndrome mediated LA cardiomyopathy was increased and anti-inflammatory treatment positively affected dysfunctional Ca2+ homeostasis. Our data indicates, that patients with HFpEF-related LA dysfunction might profit from IL-10 targeted therapy, which should be further explored in preclinical trials

    Implantable loop recorders in patients with unexplained syncope: Clinical predictors of pacemaker implantation

    Get PDF
    Background: Implantable loop recorders (ILR) are a valuable tool for the investigation of unexplained syncopal episodes. The aim of this retrospective single center study was to identify predictive factors for pacemaker implantation in patients with unexplained syncope who underwent ILR insertion. Methods: One hundred six patients were retrospectively analyzed (mean age 59.1 years; 47.2% male) with unexplained syncope and negative conventional testing who underwent ILR implantation. The pri- mary study endpoint was detection of symptomatic or asymptomatic bradycardia requiring pacemaker implantation.  Results: The average follow-up period after ILR implantation was 20 ± 15 months. Pacemaker im- plantation according to current guidelines was necessary in 22 (20.8%) patients, mean duration until index bradycardia was 81 ± 88 (2–350) days. Ten (45.5%) patients received a pacemaker due to sinus arrest, 7 (31.8%) patients due to third-degree atrioventricular block, 2 (9.1%) patients due to second- degree atrioventricular block and 1 (4.5%) patient due to atrial fibrillation with a slow ventricular rate. Three factors remained significant in multivariate analysis: obesity, which defined by a body mass index above 30 kg/m2 (OR: 7.39, p = 0.014), a right bundle branch block (OR: 9.40, p = 0.023) and chronic renal failure as defined by a glomerular filtration rate of less than 60 mL/min (OR: 6.42, p = 0.035). Conclusions: Bradycardia is a frequent finding in patients undergoing ILR implantation due to un- explained syncope. Obesity, right bundle branch block and chronic renal failure are independent clinical predictors of pacemaker implantation

    Atrial fibrillation is frequent but does not affect risk stratification in pulmonary embolism

    Get PDF
    Background: Although prior studies indicate a high prevalence of atrial fibrillation (AF) in patients with pulmonary embolism (PE), the exact prevalence and prognostic impact are unknown. Methods: We aimed to investigate the prevalence, risk factors and prognostic impact of AF on risk stratification, in-hospital adverse outcomes and mortality in 528 consecutive PE patients enrolled in a single-centre registry between 09/2008 and 09/2017. Results: Overall, 52 patients (9.8%) had known AF and 57 (10.8%) presented with AF on admission; of those, 34 (59.6%) were newly diagnosed with AF. Compared to patients with no AF, overt hyperthyroidism was associated with newly diagnosed AF (OR 7.89 [2.99–20.86]), whilst cardiovascular risk comorbidities were more frequently observed in patients with known AF. Patients with AF on admission had more comorbidities, presented more frequently with tachycardia and elevated cardiac biomarkers and were hence stratified to higher risk classes. However, AF on admission had no impact on in-hospital adverse outcome (8.3%) and in-hospital mortality (4.5%). In multivariate logistic regression analyses corrected for AF on admission, NT-proBNP and troponin elevation as well as higher risk classes in risk assessment models remained independent predictors of an in-hospital adverse outcome. Conclusion: Atrial fibrillation is a frequent finding in PE, affecting more than 10% of patients. However, AF was not associated with a higher risk of in-hospital adverse outcomes and did not affect the prognostic performance of risk assessment strategies. Thus, our data support the use of risk stratification tools for patients with acute PE irrespective of the heart rhythm on admission

    Wearable cardioverter‐defibrillator: friend or foe in suspected myocarditis?

    Get PDF
    Aim: Wearable cardioverter defibrillator (WCD, LifeVest, and Zoll) therapy has become a useful tool to bridge a temporarily increased risk for sudden cardiac death. However, despite extensive use, there is a lack of evidence whether patients with myocarditis and impaired LVEF may benefit from treatment with a WCD. Methods and results: We conducted a single-centre retrospective observational study analysing patients with a WCD prescribed between September 2015 and April 2020 at our institution. In total, 135 patients were provided with a WCD, amongst these 76 patients (mean age 48.9 +/- 13.7 years; 84.2% male) for clinically suspected myocarditis. Based on the results of the endomyocardial biopsy and, where available cardiac magnetic resonance imaging, 39 patients (51.3%) were diagnosed with myocarditis and impaired LVEF and 37 patients (48.7%) with dilated cardiomyopathy (DCM) without evidence of cardiac inflammation. The main immunohistopathological myocarditis subtype was lymphocytic myocarditis in 36 (92.3%) patients, and four patients (10.3%) of this group had an acute myocarditis. Three patients had cardiac sarcoidosis (7.7%). Ventricular tachycardia occurred in seven myocarditis (in total 41 VTs; 85.4% non-sustained) and one DCM patients (in total one non-sustained ventricular tachycardia). Calculated necessary WCD wearing time until ventricular tachycardia occurrence is 86.41 days in myocarditis compared with 6.46 years in DCM patients. Conclusions: Our data suggest that myocarditis patients may benefit from WCD therapy. However, as our study is not powered for outcome, further randomized studies powered for the outcome morbidity and mortality are necessary

    Impaired Relaxation and Reduced Lusitropic Reserve in Atrial Myocardium in the Obese Patients

    Get PDF
    Background: Obesity can influence the structure and function of the atrium, but most studies focused on the relationship of body mass index (BMI) and overt left atrium (LA) dysfunction as assessed by clinical imaging. We combined the assessment of right atrium (RA) function in vivo and in vitro in obese and non-obese patients scheduled for elective cardiac surgery. Methods: Atrial structure and function were quantified pre-operatively by echocardiography. RA tissue removed for the establishment of extracorporeal support was collected and RA trabeculae function was quantified in vitro at baseline and with adrenergic stimulation (isoproterenol). Fatty acid-binding protein 3 (FABP3) was quantified in RA tissue. Results were stratified according to the BMI of the patients. Results: About 76 patients were included pre-operatively for the echocardiographic analysis. RA trabeculae function at baseline was finally quantified from 46 patients and RA function in 28 patients was also assessed with isoproterenol. There was no significant correlation between BMI and the parameters of atrial function measured by the clinical echocardiography. However, in vitro measurements revealed a significant correlation between BMI and a prolonged relaxation of the atrial myocardium at baseline, which persisted after controlling for the atrial fibrillation and diabetes by the partial correlation analysis. Acceleration of relaxation with isoproterenol was significantly lower in the obese group (BMI ≄ 30 kg/m(2)). As a result, relaxation with adrenergic stimulation in the obese group remained significantly higher compared to the overweight group (25 kg/m(2) ≀ BMI < 30 kg/m(2), p = 0.027) and normal group (18.5 kg/m(2) ≀ BMI < 25 kg/m(2), p = 0.036). There were no differences on impacts of the isoproterenol on (systolic) developed force between groups. The expression of FABP3 in the obese group was significantly higher compared to the normal group (p = 0.049) and the correlation analysis showed the significant correlations between the level of FABP3 in the RA trabeculae function. Conclusion: A higher BMI is associated with the early subclinical changes of RA myocardial function with the slowed relaxation and reduced adrenergic lusitropy

    Low‐voltage shock impedance measurements: A false sense of security

    Get PDF
    Background: Implantable cardioverter defibrillators use low-voltage shock impedance measurements to monitor the lead integrity. However, previous case reports suggest that low-voltage shock impedance measurements may fail to detect insulation breaches that can cause life-threatening electrical short circuits. Methods and results: We report six cases of insulation breaches in transvenous defibrillation leads that were not obvious during standard interrogations and testing of the lead beforehand. In two cases, an electrical short circuit during commanded shock delivery for internal electrical cardioversion resulted in a total damage of the ICD generator. In one of these cases, commanded shock delivery induced ventricular fibrillation, which required external defibrillation. In two cases, a shock due to ventricular tachycardia was aborted as the shock impedance was less than 20 Ω. However, in both cases the tiny residual shock energy terminated the ventricular tachycardia. In contrast, in one case the residual energy of the aborted shock did not end ventricular fibrillation induced at defibrillator threshold testing. In one case, the ICD indicated an error code for a short circuit condition detected during an adequate shock delivery. Conclusions: This case series illustrates that low-voltage shock impedance measurements can fail to detect insulation breaches. These data suggest that in patients without a contraindication, traditional defibrillator threshold testing or high voltage synchronized shock at the time of device replacement should be considered
    corecore