9 research outputs found
Recommended from our members
The EGS Collab project: Status and Accomplishments
The EGS Collab project, supported by the US Department of Energy, is addressing challenges in implementing enhanced geothermal systems (EGS). This includes improving understanding of the stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The project is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory. Data and observations from the field test are compared to simulations to understand processes and to build confidence in numerical modeling of the processes. In Experiment 1, we examined hydraulic fracturing an underground test bed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km. We drilled eight sub-horizontal boreholes in a well-characterized phyllite. Six of the boreholes were instrumented with many sensor types to allow careful monitoring of stimulation events and flow tests, and the other two boreholes were used for water injection and production. We performed a number of stimulations and flow tests in the testbed. Our monitoring systems allowed detailed observations and collection of numerous data sets of processes occurring during stimulation and during dynamic flow tests. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Data were rapidly analyzed, allowing adaptive control of the tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results. Many simulations were performed in near-real-time in conjunction with the field experiments, with more detailed process study simulations performed on a longer timeframe. Experiment 2 will examine hydraulic shearing in a test bed being built at the SURF at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1. Five sets of fracture orientations were considered in design, and three orientations seem to be consistently observed
Creation of a mixed-mode fracture network at meso-scale through hydraulic fracturing and shear stimulation
Enhanced Geothermal Systems could provide a substantial contribution to the global energy demand if their implementation could overcome inherent challenges. Examples are insufficient created permeability, early thermal breakthrough, and unacceptable induced seismicity. Here we report on the seismic response of a mesoscale hydraulic fracturing experiment performed at 1.5-km depth at the Sanford Underground Research Facility. We have measured the seismic activity by utilizing a 100-kHz, continuous seismic monitoring system deployed in six 60-m length monitoring boreholes surrounding the experimental domain in 3-D. The achieved location uncertainty was on the order of 1 m and limited by the signal-to-noise ratio of detected events. These uncertainties were corroborated by detections of fracture intersections at the monitoring boreholes. Three intervals of the dedicated injection borehole were hydraulically stimulated by water injection at pressures up to 33 MPa and flow rates up to 5 L/min. We located 1,933 seismic events during several injection periods. The recorded seismicity delineates a complex fracture network comprised of multistrand hydraulic fractures and shear-reactivated, preexisting planes of weakness that grew unilaterally from the point of initiation. We find that heterogeneity of stress dictates the seismic outcome of hydraulic stimulations, even when relying on theoretically well-behaved hydraulic fractures. Once hydraulic fractures intersected boreholes, the boreholes acted as a pressure relief and fracture propagation ceased. In order to create an efficient subsurface heat exchanger, production boreholes should not be drilled before the end of hydraulic stimulations
Recommended from our members
The EGS Collab -Experiment 2 Stimulations at 1.25 km Depth
The EGS Collab project is performing well-monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory to inform challenges in implementing enhanced geothermal systems (EGS). This project, supported by the US Department of Energy, is gathering data and observations from the field tests and comparing these to simulation results to understand processes and to build confidence in numerical modeling of the processes. Experiment 1 (now complete) examined hydraulic fracturing in an underground test bed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km in a well-characterized phyllite. Geophysical monitoring instrumentation in six of eight sub-horizontal boreholes monitored stimulation events and flow tests. The other two boreholes were used to perform and carefully measure water injection and production. More than a dozen stimulations and nearly one year of flow tests in the testbed were performed. Detailed observations of processes occurring during stimulation and dynamic flow tests were collected and analyzed. Flow tests using ambient-temperature and chilled water were performed with intermittent tracer tests to examine system behavior. We achieved adaptive control of the tests using close monitoring of rapidly disseminated data and near-real-time simulation. Numerical simulation was critical in answering key experimental design questions, forecasting fracture behavior, and analyzing results. We were successful in performing many simulations in near-real-time in conjunction with the field experiments, with more detailed simulations performed later. The primary objective of Experiment 2 is to examine hydraulic shearing of natural fractures at a depth of 1.25 km in amphibolite at SURF. The stresses, rock type, and fracture conditions are different than in Experiment 1. The testbed consists of 9 boreholes, in addition to two earlier-drilled characterization boreholes. One borehole is used for injection, two fans of 2 monitoring wells have several geophysical measurement tools grouted in, and four open boreholes surrounding the injection hole are adaptively used for production and monitoring. We have encountered approximately five fracture set orientations in the testbed, and designed our testbed accordingly to maximize the potential for shear stimulation. Three stimulations have been performed to date from the injection borehole, each intersecting at least one production borehole. Different methods have been used for each stimulation, including a ramped flow, a high flow rate, and oscillating pressure
Recommended from our members
Using in-situ strain measurements to evaluate the accuracy of stress estimation procedures from fracture injection/shut-in tests
Fracture injection/shut-in tests are commonly used to measure the state of stress in the subsurface. Injection creates a hydraulic fracture (or in some cases, opens a preexisting fracture), and then the pressure after shut-in is monitored to identify fracture closure. Different interpretation procedures have been proposed for estimating closure, and the procedures sometimes yield significantly different results. In this study, direct, in-situ strain measurements are used to observe fracture reopening and closure. The tests were performed as part of the EGS Collab project, a mesoscale project performed at 1.25 and 1.5 km depth at the Sanford Underground Research Facility. The tests were instrumented with the SIMFIP tool, a double-packer probe with a high-resolution three-dimensional borehole displacement sensor. The measurements provide a direct observation of the fracture closure signature, enabling a high-fidelity estimate of the fracture closure stress (ie, the normal stress on the fracture). In two of the four tests, injection created an opening mode fracture, and so the closure stress can be interpreted as the minimum principal stress. In the other two tests, injection probably opened preexisting natural fractures, and so the closure stress can be interpreted as the normal stress on the fractures. The strain measurements are compared against different proposed methods for estimating closure stress from pressure transients. The shut-in transients are analyzed with two techniques that are widely used in the field of petroleum engineering â the âtangentâ method and the âcomplianceâ method. In three of the four tests, the tangent method significantly underestimates the closure stress. The compliance method is reasonably accurate in all four tests. Closure stress is also interpreted using two other commonly-used methods â âfirst deviation from linearityâ and the method of (Hayashi and Haimson, 1991). In comparison with the SIMFIP data, these methods tend to overestimate the closure stress, evidently because they identify closure from early-time transient effects, such as near-wellbore tortuosity. In two of the tests, microseismic imaging provides an independent estimate of the size of the fracture created by injection. When combined with a simple mass balance calculation, the SIMFIP stress measurements yield predictions of fracture size that are reasonably consistent with the estimates from microseismic. The calculations imply an apparent fracture toughness 2-3x higher than typical laboratory-derived values
Recommended from our members
Low Static Shear Modulus Along Foliation and Its Influence on the Elastic and Strength Anisotropy of Poorman Schist Rocks, Homestake Mine, South Dakota
We investigate the influence of foliation orientation and fine-scale folding on the static and dynamic elastic properties and unconfined strength of the Poorman schist. Measurements from triaxial and uniaxial laboratory experiments reveal a significant amount of variability in the static and dynamic Youngâs modulus depending on the sample orientation relative to the foliation plane. Dynamic P-wave modulus and S-wave modulus are stiffer in the direction parallel to the foliation plane as expected for transversely isotropic mediums with average Thomsen parameters values 0.133 and 0.119 for epsilon and gamma, respectively. Static Youngâs modulus varies significantly between 21 and 117 GPa, and a peculiar trend is observed where some foliated sample groups show an anomalous decrease in the static Youngâs modulus when the symmetry axis (x3-axis) is oriented obliquely to the direction of loading. Utilizing stress and strain relationships for transversely isotropic medium, we derive the analytical expression for Youngâs modulus as a function of the elastic moduli E1, E3, Îœ31, and G13 and sample orientation to fit the static Youngâs modulus measurements. Regression of the equation to the Youngâs modulus data reveals that the decrease in static Youngâs modulus at oblique symmetry axis orientations is directly influenced by a low shear modulus, G13, which we attribute to shear sliding along foliation planes during static deformation that occurs as soon as the foliation is subject to shear stress. We argue that such difference between dynamic and static anisotropy is a characteristic of near-zero porosity anisotropic rocks. The uniaxial compressive strength also shows significant variability ranging from 21.9 to 194.6 MPa across the five sample locations and is the lowest when the symmetry axis is oriented 45° or 60° from the direction of loading, also a result of shear sliding along foliation planes during static deformation
Recommended from our members
EGS Collab project: Status, tests, and data
Copyright 2019 ARMA, American Rock Mechanics Association. The EGS (Enhanced Geothermal Systems) Collab project is performing stimulation and flow experiments in highly-monitored and well-characterized intermediate-scale (approximately10 to 20 meter) field test beds at a depth of approximately 1,500 meters in the Sanford Underground Research Facility (SURF) in the Black Hills of South Dakota. Our fracture stimulation and interwell flow tests are performed to better understand processes that control formation of effective subsurface heat exchangers that are critical to the development and success of EGS. Different EGS Collab stimulations will be performed under dissimilar stress conditions to produce data for model comparisons that better differentiate stimulation mechanisms and the evolution of permeability enhancement in crystalline rock. EGS Collab experiments provide a means of testing tools, concepts, and strategies that could later be employed under geothermal reservoir conditions at DOEâs Frontier Observatory for Research in Geothermal Energy (FORGE) and other enhanced geothermal systems. Key to the project is using numerical simulations in the experiment design and interpretation o
Using in-situ strain measurements to evaluate the accuracy of stress estimation procedures from fracture injection/shut-in tests
Fracture injection/shut-in tests are commonly used to measure the state of stress in the subsurface. Injection creates a hydraulic fracture (or in some cases, opens a preexisting fracture), and then the pressure after shut-in is monitored to identify fracture closure. Different interpretation procedures have been proposed for estimating closure, and the procedures sometimes yield significantly different results. In this study, direct, in-situ strain measurements are used to observe fracture reopening and closure. The tests were performed as part of the EGS Collab project, a mesoscale project performed at 1.25 and 1.5 km depth at the Sanford Underground Research Facility. The tests were instrumented with the SIMFIP tool, a double-packer probe with a high-resolution three-dimensional borehole displacement sensor. The measurements provide a direct observation of the fracture closure signature, enabling a high-fidelity estimate of the fracture closure stress (ie, the normal stress on the fracture). In two of the four tests, injection created an opening mode fracture, and so the closure stress can be interpreted as the minimum principal stress. In the other two tests, injection probably opened preexisting natural fractures, and so the closure stress can be interpreted as the normal stress on the fractures. The strain measurements are compared against different proposed methods for estimating closure stress from pressure transients. The shut-in transients are analyzed with two techniques that are widely used in the field of petroleum engineering â the âtangentâ method and the âcomplianceâ method. In three of the four tests, the tangent method significantly underestimates the closure stress. The compliance method is reasonably accurate in all four tests. Closure stress is also interpreted using two other commonly-used methods â âfirst deviation from linearityâ and the method of (Hayashi and Haimson, 1991). In comparison with the SIMFIP data, these methods tend to overestimate the closure stress, evidently because they identify closure from early-time transient effects, such as near-wellbore tortuosity. In two of the tests, microseismic imaging provides an independent estimate of the size of the fracture created by injection. When combined with a simple mass balance calculation, the SIMFIP stress measurements yield predictions of fracture size that are reasonably consistent with the estimates from microseismic. The calculations imply an apparent fracture toughness 2-3x higher than typical laboratory-derived values
Creation of a mixedâmode fracture network at mesoscale through hydraulic fracturing and shear stimulation
Enhanced Geothermal Systems could provide a substantial contribution to the global energy demand if their implementation could overcome inherent challenges. Examples are insufficient created permeability, early thermal breakthrough, and unacceptable induced seismicity. Here we report on the seismic response of a mesoscale hydraulic fracturing experiment performed at 1.5-km depth at the Sanford Underground Research Facility. We have measured the seismic activity by utilizing a 100-kHz, continuous seismic monitoring system deployed in six 60-m length monitoring boreholes surrounding the experimental domain in 3-D. The achieved location uncertainty was on the order of 1 m and limited by the signal-to-noise ratio of detected events. These uncertainties were corroborated by detections of fracture intersections at the monitoring boreholes. Three intervals of the dedicated injection borehole were hydraulically stimulated by water injection at pressures up to 33 MPa and flow rates up to 5 L/min. We located 1,933 seismic events during several injection periods. The recorded seismicity delineates a complex fracture network comprised of multistrand hydraulic fractures and shear-reactivated, preexisting planes of weakness that grew unilaterally from the point of initiation. We find that heterogeneity of stress dictates the seismic outcome of hydraulic stimulations, even when relying on theoretically well-behaved hydraulic fractures. Once hydraulic fractures intersected boreholes, the boreholes acted as a pressure relief and fracture propagation ceased. In order to create an efficient subsurface heat exchanger, production boreholes should not be drilled before the end of hydraulic stimulations
Recommended from our members
Immune plasma for the treatment of severe influenza: an open-label, multicentre, phase 2 randomised study
BackgroundInfluenza causes substantial morbidity and mortality despite available treatments. Anecdotal reports suggest that plasma with high antibody titres to influenza might be of benefit in the treatment of severe influenza.MethodsIn this randomised, open-label, multicentre, phase 2 trial, 29 academic medical centres in the USA assessed the safety and efficacy of anti-influenza plasma with haemagglutination inhibition antibody titres of 1:80 or more to the infecting strain. Hospitalised children and adults (including pregnant women) with severe influenza A or B (defined as the presence of hypoxia or tachypnoea) were randomly assigned to receive either two units (or paediatric equivalent) of anti-influenza plasma plus standard care, versus standard care alone, and were followed up for 28 days. The primary endpoint was time to normalisation of patients' respiratory status (respiratory rate of â€20 breaths per min for adults or age-defined thresholds of 20-38 breaths per min for children) and a room air oxygen saturation of 93% or more. This study is registered with ClinicalTrials.gov, number NCT01052480.FindingsBetween Jan 13, 2011, and March 2, 2015, 113 participants were screened for eligibility and 98 were randomly assigned from 20 out of 29 participating sites. Of the participants with confirmed influenza (by PCR), 28 (67%) of 42 in the plasma plus standard care group normalised their respiratory status by day 28 compared with 24 (53%) of 45 participants on standard care alone (p=0·069). The hazard ratio (HR) comparing plasma plus standard care with standard care alone was 1·71 (95% CI 0·96-3·06). Six participants died, one (2%) from the plasma plus standard care group and five (10%) from the standard care group (HR 0·19 [95% CI 0·02-1·65], p=0·093). Participants in the plasma plus standard care group had non-significant reductions in days in hospital (median 6 days [IQR 4-16] vs 11 days [5-25], p=0·13) and days on mechanical ventilation (median 0 days [IQR 0-6] vs 3 days [0-14], p=0·14). Fewer plasma plus standard care participants had serious adverse events compared with standard care alone recipients (nine [20%] of 46 vs 20 [38%] of 52, p=0·041), the most frequent of which were acute respiratory distress syndrome (one [2%] vs two [4%] patients) and stroke (one [2%] vs two [4%] patients).InterpretationAlthough there was no significant effect of plasma treatment on the primary endpoint, the treatment seemed safe and well tolerated. A phase 3 randomised trial is now underway to further assess this intervention.FundingNational Institute of Allergy and Infectious Diseases, US National Institutes of Health