6 research outputs found

    Impact on outcome of different types of carotid stent: Results from the European Registry of Carotid Artery Stenting

    Get PDF
    AIMS: Conflicting data exist on the impact on outcome of the use of different stent types during carotid artery stenting (CAS). The aim of this study was to evaluate clinical outcomes according to different carotid stent design among the population of the European Registry of Carotid Artery Stenting (ERCAS). METHODS AND RESULTS: The present study was conducted in 1,604 patients who underwent neuroprotected CAS in ERCAS. All types of commercially available carotid stent were used. Open-cell design stents were classified according to free cell area into 7.5 mm2. A total of 713 closed-cell, 456 hybrid-cell, 238 7.5 mm2 open-cell stents were implanted. Overall, the 30-day stroke and death rate was 1.37%. At 30 days, 19 strokes occurred (1.18%): eight in the group of patients treated with a closed-cell (1.12%), two in those with a hybrid-cell (0.44%), three in those with a 7.5 mm2 open-cell stent (3.05%) (p=0.045). CONCLUSIONS: Data of the present study suggest that, in the setting of neuroprotected CAS performed in high-volume centres by properly trained operators, the use of an open-cell design stent with a free cell area >7.5 mm2 may be associated with an increased 30-day stroke risk

    European registry of carotid artery stenting: Results from a prospective registry of eight high volume EUROPEAN institutions

    No full text
    18Carotid endarterectomy (CEA) is the standard revascularization therapy to prevent stroke in patients with carotid artery disease. Carotid artery stenting (CAS) could be considered a potential alternative in patients at high surgical risk. Recent clinical trials have challenged this concept due a relatively high incidence of post-CAS adverse events, which occurred in low volume centers. The aim of this study was to evaluate the outcomes associated with neuroprotected CAS in selected high volume centers. METHODS: From January 2007 to December 2007, 1,611 patients underwent neuroprotected CAS in eight European Centers. For each patients, clinical, procedural, and one month follow-up data from all patients have been collected. An independent clinical events committee adjudicated the events. RESULTS: Overall in hospital death was 0.06% (one patient), whereas in-hospital stroke was 0.49% (eight patients). Between hospital discharge and 30 days three additional patients died (0.18%) and 10 patients experienced a stroke (0.67%). Overall 30 days mortality was 0.24% (four patients) and stroke incidence 1.12% (18 patients). The 30 day stroke/death rate was 1.36%. CONCLUSIONS: CAS is a reasonable alternative to CEA to treat carotid artery atherosclerosis in well-experienced high volume centers. These data suggest that future prospective trials comparing CAS and CEA outcomes should include only centers highly experienced in both treatment modalities. © 2012 Wiley Periodicals, Inc.reservedmixedStabile, E; Garg, P; Cremonesi, A; Bosiers, M; Reimers, B; Setacci, Carlo; Cao, P; Schmidt, A; Sievert, H; Peeters, P; Nikas, D; Werner, M; DE DONATO, Gianmarco; Parlani, G; Castriota, F; Hornung, M; Mauri, L; Rubino, P.Stabile, E; Garg, P; Cremonesi, A; Bosiers, M; Reimers, B; Setacci, Carlo; Cao, P; Schmidt, A; Sievert, H; Peeters, P; Nikas, D; Werner, M; DE DONATO, Gianmarco; Parlani, G; Castriota, F; Hornung, M; Mauri, L; Rubino, P

    Comparison of aortoiliac repair with iliac branch endoprosthesis versus hypogastric occlusion in aortoiliac aneurysms

    No full text
    BACKGROUND: The CARIBE Study aims to assess the outcome of endovascular repair (EVAR) with iliac branch endoprosthesis (IBE) in patients with aorto-iliac aneurysms extending to iliac bifurcation, comparing these results with those of EVAR with hypogastric occlusion pres¬ ent in the recent published literature. METHODS: Patients with aorto-iliac aneurysms anatomically suitable for EVAR with IBE, are included in the study. RESULTS: Primary safety outcome measure are total and aneurysm related death free survival. Efficacy endpoints include: iliac branch patency, aneurysmal sac exclusion and freedom from reinterventions or conversion to open repair. Patient reported outcomes are evaluated with Walking Impairment Questionnaire (WIQ), International Index of Erectile Function-5 (IIEF-5) and quality of life Euro-Qual EQ-5D Questionnaire. CONCLuSIONS: Comparison with recent hystorical literature obtained in patients with EVAR with HA occlusion will offer data useful for correct information of patients affected by aorto-iliac aneurysms

    Editor's Choice - Early Outcomes of a Novel Off the Shelf Preloaded Inner Branch Endograft for the Treatment of Complex Aortic Pathologies in the ItaliaN Branched Registry of E-nside EnDograft (INBREED)

    No full text
    Objective: The aim of this study was to investigate the early outcomes of a novel off the shelf pre-loaded inner branched thoraco-abdominal endograft (E-nside) in the treatment of aortic pathologies. Methods: Data from a physician initiated national multicentre registry on patients treated with the E-nside endograft, were prospectively collected and analysed. Pre-operative clinical and anatomical characteristics, procedural data, and early outcomes (90 days) were recorded in a dedicated electronic data capture system. The primary endpoint was technical success. Secondary endpoints were early mortality (90 days), procedural metrics, target vessel patency, endoleak rate, and major adverse events (MAEs) at 90 days. Results: In total, 116 patients from 31 Italian centres were included. Mean ± standard deviation (SD) patient age was 73 ± 8 years and 76 (65.5%) were male. Aortic pathologies included degenerative aneurysm in 98 (84.5%), post-dissection aneurysm in five (4.3%), pseudoaneurysm in six (5.2%), penetrating aortic ulcer or intramural haematoma in four (3.4%), and subacute dissection in three (2.6%). Mean ± SD aneurysm diameter was 66 ± 17 mm; aneurysm extent was Crawford I - III in 55 (50.4%), IV in 21 (19.2%), pararenal in 29 (26.7%), and juxtarenal in four (3.7%). The procedure setting was urgent in 25 (21.5%) patients. Median procedural time was 240 minutes (interquartile range [IQR] 195, 303), with a median contrast volume of 175 mL (IQR 120, 235). The endograft's technical success rate was 98.2% and the 90 day mortality rate was 5.2% (n = 6; 2.1% for elective repair and 16% for urgent repair). The 90-days cumulative MAE rate was 24.1% (n = 28). At 90 days, there were 10 (2.3%) target vessel related events (nine occlusions and one type IC endoleak) and one type 1A endoleak requiring re-intervention. Conclusion: In this real life, non-sponsored registry, the E-nside endograft was used for the treatment of a broad spectrum of aortic pathologies, including urgent cases and different anatomies. The results showed excellent technical implantation safety and efficacy, as well as early outcomes. Longer term follow up is needed to better define the clinical role of this novel endograft
    corecore