5,001 research outputs found

    Area- and Energy- Efficient Modular Circuit Architecture for 1,024-Channel Parallel Neural Recording Microsystem.

    Full text link
    This research focuses to develop system architectures and associated electronic circuits for a next generation neuroscience research tool, a massive-parallel neural recording system capable of recording 1,024 channels simultaneously. Three interdependent prototypes have been developed to address major challenges in realization of the massive-parallel neural recording microsystems: minimization of energy and area consumption while preserving high quality in recordings. First, a modular 128-channel Δ-ΔΣ AFE using the spectrum shaping has been designed and fabricated to propose an area-and energy efficient solution for neural recording AFEs. The AFE achieved 4.84 fJ/C−s·mm2 figure of merit that is the smallest the area-energy product among the state-of-the-art multichannel neural recording systems. It also features power and area consumption of 3.05 µW and 0.05 mm2 per channel, respectively while exhibiting 63.3 dB signal-to-noise ratio with 3.02 µVrms input referred noise. Second, an on-chip mixed signal neural signal compressor was built to reduce the energy consumption in handling and transmission of the recorded data since this occupies a large portion of the total energy consumption as the number of parallel recording increases. The compressor reduces the data rates of two distinct groups of neural signals that are essential for neuroscience research: LFP and AP without loss of informative signals. As a result, the power consumptions for the data handling and transmissions of the LFP and AP were reduced to about 1/5.35 and 1/10.54 of the uncompressed cases, respectively. In the total data handling and transmission, the measured power consumption per channel is 11.98 µW that is about 1/9 of 107.5 µW without the compression. Third, a compact on-chip dc-to-dc converter with constant 1 MHz switching frequency has been developed to provide reliable power supplies and enhance energy delivery efficiency to the massive-parallel neural recording systems. The dc-to-dc converter has only predictable tones at the output and it exhibits > 80% power conversion efficiency at ultra-light loads, < 100 µW that is relevant power most of the multi-channel neural recording systems consume. The dc-to-dc converter occupies 0.375 mm2 of area which is less than 1/20 of the area the first prototype consumes (8.64 mm2).PhDElectrical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/133244/1/sungyun_1.pd

    Larval development of the sidestriped shrimp (Pandalopsis dispar Rathbun) (Crustacea, Decapoda, Pandalidae) reared in the laboratory

    Get PDF
    Larval development of the sidestriped shrimp (Pandalopsis dispar) is described from larvae reared in the laboratory. The species has five zoeal stages and one postlarval stage. Complete larval morphological characteristics of the species are described and compared with those of related species of the genus. The number of setae on the margin of the telson in the first and second stages is variable: 11+12, 12+12, or 11+11. Of these, 11+12 pairs are most common. The present study confirms that what was termed the fifth stage in the original study done by Berkeley in 1930 was the sixth stage and that the fifth stage in the Berkeley’s study is comparable to the sixth stage that is described in the present study. The sixth stage has a segmented inner flagellum of the antennule and fully developed pleopods with setae. The ability to distinguish larval stages of P. dispar from larval stages of other plankton can be important for studies of the effect of climate change on marine communities in the Northeast Pacific and for marine resource management strategies

    Toward a Standardized Strategy of Clinical Metabolomics for the Advancement of Precision Medicine

    Get PDF
    Despite the tremendous success, pitfalls have been observed in every step of a clinical metabolomics workflow, which impedes the internal validity of the study. Furthermore, the demand for logistics, instrumentations, and computational resources for metabolic phenotyping studies has far exceeded our expectations. In this conceptual review, we will cover inclusive barriers of a metabolomics-based clinical study and suggest potential solutions in the hope of enhancing study robustness, usability, and transferability. The importance of quality assurance and quality control procedures is discussed, followed by a practical rule containing five phases, including two additional "pre-pre-" and "post-post-" analytical steps. Besides, we will elucidate the potential involvement of machine learning and demonstrate that the need for automated data mining algorithms to improve the quality of future research is undeniable. Consequently, we propose a comprehensive metabolomics framework, along with an appropriate checklist refined from current guidelines and our previously published assessment, in the attempt to accurately translate achievements in metabolomics into clinical and epidemiological research. Furthermore, the integration of multifaceted multi-omics approaches with metabolomics as the pillar member is in urgent need. When combining with other social or nutritional factors, we can gather complete omics profiles for a particular disease. Our discussion reflects the current obstacles and potential solutions toward the progressing trend of utilizing metabolomics in clinical research to create the next-generation healthcare system.11Ysciescopu

    The Analysis of Antecedents for the Video Telephony Service Adoption: From the Value-Based Perspective

    Get PDF
    Korean Telecommunications Industry has a large scale market and boasts on high service quality and high technologies enough to provide the Video Telephony Service (VTS) satisfactorily. For many years, Korean telephone companies have been investing enormous sums to advertise their services widely and to allow their customers to change their cell phones for the third-generation (3G) devices indispensable for the service. However, despite their efforts, the VTS adoption rate in Korea is very low and it seems that customers seldom feel the necessity to use. From this viewpoint, it becomes necessary to find the antecedents influencing the intention to use for the VTS empirically. For this purpose, we proposed several hypotheses from the perspective of the Value-based Adoption Model (VAM). VAM is a conceptual model suggested to overcome some limitations of the Technology Acceptance Model (TAM) in explaining the adoption of new Information and Communication Technology (ICT) such as Mobile Internet where customers play the role of service consumer rather than simply technology users. We conducted a survey on 125 samples and found that customers perceive the value of VTS when they can recognize the service is functionally useful (Perceived Usefulness) and when they feel they can put themselves forward by using it (Self-Expression). On the other hand, the other factors including Technical Complexity, Privacy Concern and Perceived Price (Fee) don’t have statistically significant influences on the Perceived Value of VTS

    Disturbance of greedy publishing to academia

    Full text link
    Questionable publications have been accused of "greedy" practices; however, their influence on academia has not been gauged. Here, we probe the impact of questionable publications through a systematic and comprehensive analysis with various participants from academia and compare the results with those of their unaccused counterparts using billions of citation records, including liaisons, e.g., journals and publishers, and prosumers, e.g., authors. The analysis reveals that questionable publications embellished their citation scores by attributing publisher-level self-citations to their journals while also controlling the journal-level self-citations to circumvent the evaluation of journal-indexing services. This approach makes it difficult to detect malpractice by conventional journal-level metrics. We propose journal-publisher-hybrid metric that help detect malpractice. We also demonstrate that the questionable publications had a weaker disruptiveness and influence than their counterparts. This indicates the negative effect of suspicious publishers in the academia. The findings provide a basis for actionable policy making against questionable publications.Comment: 16 pages of main text including 4 figures + 32 pages of supplementary information including 30 supplementary figure

    Outcomes of endovascular treatment for aortic pseudoaneurysm in Behcet's disease

    Get PDF
    ObjectiveTo evaluate the effectiveness of endovascular stent grafting for surgical management of aortic pseudoaneurysm in patients with Behcet's disease (BD).MethodsWe present a single-institution retrospective cohort of patients with aortic pseudoaneurysm and BD treated with aortic stent grafting. Computed tomography imaging was obtained preoperatively in all patients and once within 2 weeks postoperatively, and then annually. Clinical follow-up and erythrocyte sedimentation rate were used to follow BD activity. Immunosuppressant therapy was instituted prior to endovascular treatment unless a contraindication existed.ResultsFrom 1998 to 2012, 10 patients (eight male, two female; median age, 39) with BD and aortic pseudoaneurysm were treated with endovascular stent grafting at this institution. Ninety percent of these patients received immunosuppressive therapy before and after surgical treatment. The median follow-up period was 57 months (interquartile range, 43-72). The locations of the 12 pseudoaneurysms treated in this cohort were infrarenal abdominal aorta (seven), descending thoracic aorta (four), and aortic arch (one). Median pseudoaneurysm size was 4.5 cm (interquartile range, 3.4-5.9). At long-term follow-up, complete resolution of the aortic pseudoaneurysm was noted in all patients. No endoleaks occurred. Newly developed pseudoaneurysm at the distal margin of the stent graft was noted in one patient 17 months after the stent graft procedure. One patient required a subsequent stent graft placement for an expanding pseudoaneurysm of the subclavian artery. No patient deaths occurred during the follow-up period.ConclusionsEndovascular treatment of aortic pseudoaneurysm with stent-grafting in patients with BD is safe and effective with long-term durability
    corecore