    Combined radioimmunotherapy and radiotherapy of liver metastases from colorectal cancer: a feasibility study.

    No full text
    BACKGROUND: A combination of radioimmunotherapy (RIT) and radiotherapy (RT) should allow one to increase the dose of radiation targeting a particular tumour without the concomitant increase of toxic side effects. This might be obtained if the dose limiting side effect of each individual radiation therapy concerned different organs. METHODS: Six patients with limited liver metastatic disease from colorectal cancer were treated with 6.9 GBq (range 4.7 to 8.4 GBq) 131I-labelled anti-CEA MAb F(ab')2 fragments combined with 20 Gy RT to the liver. Both treatments were given in close association, according to timing schedules evaluated in animals that gave the best results. RESULTS: Reversible bone marrow and liver toxicity was observed in 6 and 5 patients, respectively. Three patients who first received 20 Gy RT to the liver, showed a significant platelet drop upon completion of RT. Repeat computerized tomography (CT) after 2 months showed a minor response in 1 patient and stable disease in 3 patients. CONCLUSION: The study shows potential ways of combining RIT and RT, suggesting that this combination is feasible for the treatment of liver metastases

    Phantom-based image quality assessment of clinical <sup>18</sup>F-FDG protocols in digital PET/CT and comparison to conventional PMT-based PET/CT.

    Get PDF
    We assessed and compared image quality obtained with clinical &lt;sup&gt;18&lt;/sup&gt; F-FDG whole-body oncologic PET protocols used in three different, state-of-the-art digital PET/CT and two conventional PMT-based PET/CT devices. Our goal was to evaluate an improved trade-off between administered activity (patient dose exposure/signal-to-noise ratio) and acquisition time (patient comfort) while preserving diagnostic information achievable with the recently introduced digital detector technology compared to previous analogue PET technology. We performed list-mode (LM) PET acquisitions using a NEMA/IEC NU2 phantom, with activity concentrations of 5 kBq/mL and 25 kBq/mL for the background (9.5 L) and sphere inserts, respectively. For each device, reconstructions were obtained varying the image statistics (10, 30, 60, 90, 120, 180, and 300 s from LM data) and the number of iterations (range 1 to 10) in addition to the employed local clinical protocol setup. We measured for each reconstructed dataset: the quantitative cross-calibration, the image noise on the uniform background assessed by the coefficient of variation (COV), and the recovery coefficients (RCs) evaluated in the hot spheres. Additionally, we compared the characteristic time-activity-product (TAP) that is the product of scan time per bed position × mass-activity administered (in min·MBq/kg) across datasets. Good system cross-calibration was obtained for all tested datasets with &lt; 6% deviation from the expected value was observed. For all clinical protocol settings, image noise was compatible with clinical interpretation (COV &lt; 15%). Digital PET showed an improved background signal-to-noise ratio as compared to conventional PMT-based PET. RCs were comparable between digital and PMT-based PET datasets. Compared to PMT-based PET, digital systems provided comparable image quality with lower TAP (from ~ 40% less and up to 70% less). This study compared the achievable clinical image quality in three state-of-the-art digital PET/CT devices (from different vendors) as well as in two conventional PMT-based PET. Reported results show that a comparable image quality is achievable with a TAP reduction of ~ 40% in digital PET. This could lead to a significant reduction of the administered mass-activity and/or scan time with direct benefits in terms of dose exposure and patient comfort
    corecore