12 research outputs found

    Ultrasound-Guided Placement of a Renal Artery Stent Using an Intracardiac Probe for Transvascular Imaging

    Get PDF
    In this set of images obtained during an experimental study using a porcine animal model, we introduce ultrasound guidance of percutaneous transluminal renal angioplasty and renal stenting. A state-of-the-art intracardiac ultrasound catheter is used here for transvascular scanning from within the lumen of the abdominal aorta, thus providing a field of view for navigation of a balloon catheter and a wire coil (“stent”) into each renal artery of a pig. This study is intended as a contribution to the growing field of minimally invasive interventions and their navigation by non-ionizing ultrasound imaging

    Impact of pericardial adhesions on diastolic function as assessed by vortex formation time, a parameter of transmitral flow efficiency

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pericardial adhesions are a pathophysiological marker of constrictive pericarditis (CP), which impairs cardiac filling by limiting the total cardiac volume compliance and diastolic filling function. We studied diastolic transmitral flow efficiency as a new parameter of filling function in a pericardial adhesion animal model. We hypothesized that vortex formation time (VFT), an index of optimal efficient diastolic transmitral flow, is altered by patchy pericardial-epicardial adhesions.</p> <p>Methods</p> <p>In 8 open-chest pigs, the heart was exposed while preserving the pericardium. We experimentally simulated early pericardial constriction and patchy adhesions by instilling instant glue into the pericardial space and using pericardial-epicardial stitches. We studied left ventricular (LV) function and characterized intraventricular blood flow with conventional and Doppler echocardiography at baseline and following the experimental intervention.</p> <p>Results</p> <p>Significant decreases in end-diastolic volume, ejection fraction, stroke volume, and late diastolic filling velocity reflected the effects of the pericardial adhesions. The mean VFT value decreased from 3.61 ± 0.47 to 2.26 ± 0.45 (P = 0.0002). Hemodynamic variables indicated the inhibiting effect of pericardial adhesion on both contraction (decrease in systolic blood pressure and +dP/dt decreased) and relaxation (decrease in the magnitude of -dP/dt and prolongation of Tau) function.</p> <p>Conclusion</p> <p>Patchy pericardial adhesions not only negatively impact LV mechanical functioning but the decrease of VFT from normal to suboptimal value suggests impairment of transmitral flow efficiency.</p

    Epicardial Fat and Its Association with Cardiovascular Risk: A Cross-Sectional Observational Study

    No full text
    Background: The association between visceral obesity and cardiovascular risk has been well described. Some studies show a proportional relationship between the presence of visceral obesity and epicardial fat. Measuring the amount of epicardial adipose tissue (EAT) can be a novel parameter that is inexpensive and easy to obtain and may be helpful in cardiovascular risk stratification. However, the relationship between epicardial fat and cardiac function and that between epicardial fat and cardiac risk factors is less well described. Objectives: To evaluate the association between echocardiographic epicardial fat and the morphologic and physiologic changes observed at echocardiography and to evaluate the association between epicardial fat and cardiac risk factors. A cross-sectional study of 97 echocardiographic studies (females, n = 42) was conducted. Two groups were identified: epicardial fat ≥ 5 mm (group I) and <5 mm (group II). Results: Epicardial fat >5 mm was associated with LA enlargement, with lower ejection fraction, increased left ventricular mass, and abnormal diastolic function. On a multivariable regression analysis, all these parameters also correlated individually with EAT thickness independent of age. Hyperglycemia (DM), systolic hypertension, and lipid parameters for metabolic syndrome showed a trend for positive association, but this was not statistically significant. The association was not significant even for higher cutoff limits of EAT thickness. Conclusion: Epicardial fat >5 mm is associated with cardiac abnormalities on echocardiography. This is a sensitive assessment of body fat distribution, is easily available at echocardiography, and is simple to acquire at no added cost. Further studies looking at the appropriate cut-off thickness of EAT and the sites of measurement to be used are needed. Comparison of this simple and inexpensive measure with other measures of obesity, such as waist-hip ratio, body mass index, Dexa scan of visceral fat, and magnetic resonance imaging of visceral, are needed

    Patients with Alzheimer disease have altered transmitral flow: Echocardiographic analysis of the vortex formation time

    No full text
    Objective. There is considerable epidemiologic evidence that Alzheimer disease (AD) is linked to cardiovascular risk factors and associated with an increased risk of symptomatic left ventricular (LV) dysfunction. Formation of a vortex alongside a diastolic jet signifies an efficient blood transport mechanism. The vortex formation time (VFT) is an index of optimal conditions for vortex formation. We hypothesized that AD and its associated cardiovascular risk factors impair diastolic transmitral flow efficiency and, therefore, shift the VFT value out of its optimal range. Methods. Echocardiographic studies were performed on 45 participants in total: 22 patients with AD diagnosed according to the American Psychiatric Association\u27s criteria and 23 age-matched individuals as a control group with cognitive function within normal limits. Results. The echocardiographic ratio of the early to atrial phases of the LV filling velocities was significantly lower in the AD group (mean ± SD, 0.67 ± 14) when compared with the control individuals (0.79 ± 0.14; P = .003). The interventricular septum diastolic thickness, left ventricular posterior wall diastolic thickness, and right ventricular end-diastolic diameter were significantly higher in the AD group (P ≤ 0.04). The mitral annular diameters in the control and AD groups were nearly identical (P = .725). The time-velocity integral of the E wave had a lower value in the AD group than in the control group (P = .05), whereas the VFT was significantly lower in the AD group (P = .018). Conclusions. Our study suggests that patients with AD have impaired transmitral flow efficiency of diastolic filling, as measured by the VFT, compared with age-matched control individuals. © 2009 by the American Institute of Ultrasound in Medicine
    corecore