167 research outputs found

    Grace Paley: 02-18-1982

    Get PDF
    In an interview recorded February 18, 1982, Grace Paley reads her short story Wants and discusses her beginnings as a writer, her switch from poetry to the short story, writing while raising children, her political activism, and her strong streak of indolence.https://digitalcommons.brockport.edu/writers_videos/1042/thumbnail.jp

    Corneoscleral laceration and ocular burns caused by electronic cigarette explosions

    Get PDF
    PURPOSE: To report cases of acute globe rupture and bilateral corneal burns from electronic cigarette (EC) explosions. METHODS: Case series. RESULTS: We describe a series of patients with corneal injury caused by EC explosions. Both patients suffered bilateral corneal burns and decreased visual acuity, and one patient sustained a unilateral corneoscleral laceration with prolapsed iris tissue and hyphema. A review of the scientific literature revealed no prior reported cases of ocular injury secondary to EC explosions; however, multiple media and government agency articles describe fires and explosions involving ECs, including at least 4 with ocular injuries. CONCLUSIONS: Given these cases and the number of recent media reports, ECs pose a significant public health risk. Users should be warned regarding the possibility of severe injury, including sight-threatening ocular injuries ranging from corneal burns to full-thickness corneoscleral laceration

    Crowdsourced assessment of surgical skill proficiency in cataract surgery

    Get PDF
    OBJECTIVE: To test whether crowdsourced lay raters can accurately assess cataract surgical skills. DESIGN: Two-armed study: independent cross-sectional and longitudinal cohorts. SETTING: Washington University Department of Ophthalmology. PARTICIPANTS AND METHODS: Sixteen cataract surgeons with varying experience levels submitted cataract surgery videos to be graded by 5 experts and 300+ crowdworkers masked to surgeon experience. Cross-sectional study: 50 videos from surgeons ranging from first-year resident to attending physician, pooled by years of training. Longitudinal study: 28 videos obtained at regular intervals as residents progressed through 180 cases. Surgical skill was graded using the modified Objective Structured Assessment of Technical Skill (mOSATS). Main outcome measures were overall technical performance, reliability indices, and correlation between expert and crowd mean scores. RESULTS: Experts demonstrated high interrater reliability and accurately predicted training level, establishing construct validity for the modified OSATS. Crowd scores were correlated with (r = 0.865, p \u3c 0.0001) but consistently higher than expert scores for first, second, and third-year residents (p \u3c 0.0001, paired t-test). Longer surgery duration negatively correlated with training level (r = -0.855, p \u3c 0.0001) and expert score (r = -0.927, p \u3c 0.0001). The longitudinal dataset reproduced cross-sectional study findings for crowd and expert comparisons. A regression equation transforming crowd score plus video length into expert score was derived from the cross-sectional dataset (r CONCLUSIONS: Crowdsourced rankings correlated with expert scores, but were not equivalent; crowd scores overestimated technical competency, especially for novice surgeons. A novel approach of adjusting crowd scores with surgery duration generated a more accurate predictive model for surgical skill. More studies are needed before crowdsourcing can be reliably used for assessing surgical proficiency

    Corneal perforation in ocular graft-versus-host disease

    Get PDF
    PURPOSE: Corneal perforation is a rare, vision-threatening complication of ocular graft-versus-host disease (GVHD) and is not well understood. Our objective was to examine the clinical disease course and histopathologic correlation in patients who progressed to this outcome. METHODS: This study is a retrospective case series from four academic centers in the United States. All patients received a hematopoietic stem cell transplant (HSCT) prior to developing ocular GVHD. Variables of interest included patient demographics, time interval between HSCT and ocular events, visual acuity throughout clinical course, corticosteroid and infection prophylaxis regimens at time of corneal perforation, medical/surgical interventions, and histopathology. RESULTS: Fourteen eyes from 14 patients were analyzed. Most patients were male (86%) and Caucasian (86%), and average age at time of hematopoietic stem cell transplant was 47 years. The mean interval between hematopoietic stem cell transplant and diagnosis of ocular graft-versus-host disease was 9.5 months, and between hematopoietic stem cell transplant and corneal perforation was 37 months. Initial best-corrected visual acuity was 20/40 or better in 9 eyes, and all eyes had moderate or poor visual outcomes despite aggressive management, including corneal gluing in all patients followed by keratoplasty in 8 patients. The mean follow-up after perforation was 34 months (range 2-140 months). Oral prednisone was used prior to perforation in 11 patients (79%). On histopathology, representative specimens in the acute phase demonstrated ulcerative keratitis with perforation but minimal inflammatory cells and no microorganisms, consistent with sterile corneal melt in the setting of immunosuppression; and in the healed phase, filling in of the perforation site with fibrous scar. CONCLUSIONS: In these patients, an extended time interval was identified between the diagnosis of ocular graft-versus-host disease and corneal perforation. This represents a critical window to potentially prevent this devastating outcome. Further study is required to identify those patients at greatest risk as well as to optimize prevention strategies

    Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment

    Full text link
    The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3σ\sigma (5σ\sigma) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3σ\sigma level with a 100 kt-MW-yr exposure for the maximally CP-violating values \delta_{\rm CP}} = \pm\pi/2. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest

    Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector

    Full text link
    Measurements of electrons from νe\nu_e interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.Comment: 19 pages, 10 figure

    Long-baseline neutrino oscillation physics potential of the DUNE experiment

    Get PDF
    The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is determined, based on a full simulation, reconstruction, and event selection of the far detector and a full simulation and parameterized analysis of the near detector. Detailed uncertainties due to the flux prediction, neutrino interaction model, and detector effects are included. DUNE will resolve the neutrino mass ordering to a precision of 5σ, for all ΑCP values, after 2 years of running with the nominal detector design and beam configuration. It has the potential to observe charge-parity violation in the neutrino sector to a precision of 3σ (5σ) after an exposure of 5 (10) years, for 50% of all ΑCP values. It will also make precise measurements of other parameters governing long-baseline neutrino oscillation, and after an exposure of 15 years will achieve a similar sensitivity to sin22θ13 to current reactor experiments

    Long-baseline neutrino oscillation physics potential of the DUNE experiment

    Get PDF
    The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is determined, based on a full simulation, reconstruction, and event selection of the far detector and a full simulation and parameterized analysis of the near detector. Detailed uncertainties due to the flux prediction, neutrino interaction model, and detector effects are included. DUNE will resolve the neutrino mass ordering to a precision of 5σ, for all δ_(CP) values, after 2 years of running with the nominal detector design and beam configuration. It has the potential to observe charge-parity violation in the neutrino sector to a precision of 3σ (5σ) after an exposure of 5 (10) years, for 50% of all δ_(CP) values. It will also make precise measurements of other parameters governing long-baseline neutrino oscillation, and after an exposure of 15 years will achieve a similar sensitivity to sin²θ₁₃ to current reactor experiments

    First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

    Get PDF
    The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP\u27s performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP\u27s successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design

    Prospects for beyond the Standard Model physics searches at the Deep Underground Neutrino Experiment

    Get PDF
    The Deep Underground Neutrino Experiment (DUNE) will be a powerful tool for a variety of physics topics. The high-intensity proton beams provide a large neutrino flux, sampled by a near detector system consisting of a combination of capable precision detectors, and by the massive far detector system located deep underground. This configuration sets up DUNE as a machine for discovery, as it enables opportunities not only to perform precision neutrino measurements that may uncover deviations from the present three-flavor mixing paradigm, but also to discover new particles and unveil new interactions and symmetries beyond those predicted in the Standard Model (SM). Of the many potential beyond the Standard Model (BSM) topics DUNE will probe, this paper presents a selection of studies quantifying DUNE’s sensitivities to sterile neutrino mixing, heavy neutral leptons, non-standard interactions, CPT symmetry violation, Lorentz invariance violation, neutrino trident production, dark matter from both beam induced and cosmogenic sources, baryon number violation, and other new physics topics that complement those at high-energy colliders and significantly extend the present reach
    corecore