603 research outputs found
Stabilization of class-B broad-area lasers emission by external optical injection
We theoretically examine the effect of external optical injection on the
spatio-temporal dynamics of class-B broad-area lasers. We demonstrate that
optical injection can efficiently stabilize the intrinsic transverse
instabilities in such lasers associated with both the boundaries of the pumping
area and with the bulk nonlinearities of the active medium. Stabilizing action
of optical injection is shown to be closely related to the suppression of
inherent relaxation oscillations behavior.Comment: 8 pages, 7 figure
Generation of unipolar half-cycle pulse via unusual reflection of a single-cycle pulse from an optically thin metallic or dielectric layer
We present a significantly different reflection process from an optically
thin flat metallic or dielectric layer and propose a strikingly simple method
to form approximately unipolar half-cycle optical pulses via reflection of a
single-cycle optical pulse. Unipolar pulses in reflection arise due to
specifics of effectively one-dimensional pulse propagation. Namely, we show
that in considered system the field emitted by a flat medium layer is
proportional to the velocity of oscillating medium charges instead of their
acceleration as it is usually the case. When the single-cycle pulse interacts
with linear optical medium, the oscillation velocity of medium charges can be
then forced to keep constant sign throughout the pulse duration. Our results
essentially differ from the direct mirror reflection and suggest a possibility
of unusual transformations of the few-cycle light pulses in linear optical
systems
Position-sensitive detector for the 6-meter optical telescope
The Position-Sensitive Detector (PSD) for photometrical and spectral
observation on the 6-meter optical telescope of the Special Astrophysical
Observatory (Russia) is described. The PSD consists of a position-sensitive
tube, amplifiers of output signals, analog-to-digital converters (ADC) and a
digital logic plate, which produces a signal for ADC start and an external
strob pulse for reading information by registration system. If necessary, the
thermoelectric cooler can be used. The position-sensitive tube has the
following main elements: a photocathode, electrodes of inverting optics, a
block of microchannel plates (MCP) and a position-sensitive collector of
quadrant type. The main parameters of the PSD are the diameter of the sensitive
surface is 25 mm, the spatial resolution is better than 100 (\mu)m in the
centre and a little worse on the periphery; the dead time is near 0.5 (\mu)s;
the detection quantum efficiency is defined by the photocathode and it is not
less than 0.1, as a rule; dark current is about hundreds of cps, or less, when
cooling. PSD spectral sensitivity depends on the type of photocathode and input
window material. We use a multialkali photocathode and a fiber or UV-glass,
which gives the short- wave cut of 360 nm or 250 nm, respectively.Comment: 4 pages, 7 figures, to be published in Nuclear Instruments & Methods
in Physics Researc
- …