25 research outputs found
Left atrial tachycardia after circumferential pulmonary vein ablation for atrial fibrillation Electroanatomic characterization and treatment
ObjectivesThe purpose of this study was to evaluate the electroanatomic characteristics of left atrial tachycardia (AT) in a series of patients who underwent circumferential pulmonary vein ablation (CPVA) and to describe the ablation strategy and clinical outcome.BackgroundCircumferential pulmonary vein ablation is an effective treatment for atrial fibrillation. A potential midterm complication is the development of left AT. There are only isolated reports describing mapping and ablation of such arrhythmias.MethodsThirteen patients (age 57.4 ± 8.9 years, five female) underwent mapping and ablation of 14 left ATs via an electroanatomic mapping system a mean of 2.6 ± 1.6 months after CPVA.ResultsThree patients were characterized as having focal AT (cycle length: 266 ± 35.9 ms). Of 11 macroâre-entrant tachycardias studied in the remaining 10 patients (cycle length: 275 ± 75 ms), 5 showed single-loop and 6 dual-loop circuits. Re-entrant circuits used the mitral isthmus, the posterior wall, or gaps on previous encircling lines. Such gaps and all three foci occurred anterior to the left superior pulmonary vein or at the septal aspect of the right pulmonary veins. Thirteen of 14 tachycardias (93%) were successfully ablated.ConclusionsLeft AT after CPVA can be due to a macroâre-entrant or focal mechanism. Re-entry occurs most commonly across the mitral isthmus, the posterior wall, or gaps on previous ablation lines. Such gaps and foci occur most commonly at the anterior aspect of the left superior pulmonary vein and at the septal aspect of the right pulmonary veins. These arrhythmias can be successfully mapped and ablated with an electroanatomic mapping system
The Natural History of Asymptomatic Ventricular Pre-Excitation A Long-Term Prospective Follow-Up Study of 184 Asymptomatic Children
ObjectivesThe aim of this study was to describe the natural history of asymptomatic ventricular pre-excitation in children and to determine predictors of potentially life-threatening arrhythmic events.BackgroundSudden death can be the first clinical manifestation in asymptomatic children with ventricular pre-excitation, but reduction of its incidence by prophylactic ablation requires the identification of subjects at high risk.MethodsBetween 1995 and 2005 we prospectively collected clinical and electrophysiologic data from 184 children (66% male; median age 10 years; range 8 to 12 years) with asymptomatic ventricular pre-excitation on the electrocardiogram. After electrophysiologic testing, subjects were followed as outpatients taking no medications. The primary end point of the study was the occurrence of arrhythmic events. Predictors of potentially life-threatening arrhythmias were analyzed.ResultsOver a median follow-up of 57 months (min/max 32/90 months) after electrophysiologic testing, 133 children (mean age 10 years; range 8 to 12 years) did not experience arrhythmic events, remaining totally asymptomatic, while 51 children had within 20 months (min/max 8/60 months) a first arrhythmic event, which was potentially life-threatening in 19 of them (mean age 10 years; range 10 to 14 years). Life-threatening tachyarrhythmias resulted in cardiac arrest (3 patients), syncope (3 patients), atypical symptoms (8 patients), or minimal symptoms (5 patients). Univariate analysis identified tachyarrhythmia inducibility (p < 0.001), anterograde refractory period of accessory pathways (APERP) â€240 ms (p < 0.001), and multiple accessory pathways (p < 0.001) as risk factors for potentially life-threatening arrhythmic events. Independent predictors by multivariate analysis were APERP (p = 0.001) and multiple accessory pathway (p = 0.001).ConclusionsThese findings are potentially relevant in terms of early identification of high-risk asymptomatic children with ventricular pre-excitation. Subjects with short APERPs and multiple pathways are at higher risk of developing life-threatening arrhythmic events and are the best candidates for prophylactic ablation
Electrocardiographic findings in patients with arrhythmogenic cardiomyopathy and right bundle branch block ventricular tachycardia
AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data.
METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available.  Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV.
CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants
The PhysioVP-AF study, a randomized controlled trial to assess the clinical benefit of physiological ventricular pacing vs. managed ventricular pacing for persistent atrial fibrillation prevention in patients with prolonged atrioventricular conduction: design and rationale
Aims: In patients with prolonged atrioventricular (AV) conduction and pacemaker (PM) indication due to sinus node disease (SND) or intermittent AV-block who do not need continuous ventricular pacing (VP), it may be difficult to determine which strategy to adopt. Currently, the standard of care is to minimize unnecessary VP by specific VP avoidance (VPA) algorithms. The superiority of this strategy over standard DDD or DDD rate-responsive (DDD/DDDR) in improving clinical outcomes is controversial, probably owing to the prolongation of the atrialventricular conduction (PR interval) caused by the algorithms. Conduction system pacing (CSP) may offer the most physiological-VP approach, providing appropriate AV conduction and preventing pacing-induced dyssynchrony. Methods and results: PhysioVP-AF is a prospective, controlled, randomized, single-blind trial designed to determine whether atrial-synchronized conduction system pacing (DDD-CSP) is superior to standard DDD-VPA pacing in terms of 3-year reduction of persistent-AF occurrence. Cardiovascular hospitalization, quality-of-life, and safety will be evaluated. Patients with indication for permanent DDD pacing for SND or intermittent AV-block and prolonged AV conduction (PR interval > 180 ms) will be randomized (1:1 ratio) to DDD-VPA (VPA-algorithms ON, septal/apex position) or to DDD-CSP (His bundle or left bundle branch area pacing, AV-delay setting to control PR interval, VPA-algorithms OFF). Approximately 400 patients will be randomized in 24 months in 13 Italian centres. Conclusion: The PhysioVP-AF study will provide an essential contribution to patient management with prolonged AV conduction and PM indication for sinus nodal disease or paroxysmal 2nd-degree AV-block by determining whether CSP combined with a controlled PR interval is superior to standard management that minimizes unnecessary VP in terms of reducing clinical outcomes
Step by Step through the Years—High vs. Low Energy Lead Extraction Using Advanced Extraction Techniques
Background: Limited data is available about the outcome of TLE in patients with vs. without high energy leads in the last decade. Methods: This is an analysis of consecutive patients undergoing TLE at a high-volume TLE centre from 2001 to 2021 using the stepwise approach. Baseline characteristics, procedural details and outcome of patients with high energy lead (ICD group) vs. without high energy lead (non-ICD group) were compared. Results: Out of 667 extractions, 991 leads were extracted in 405 procedures (60.7%) in the ICD group and 439 leads in 262 procedures (39.3%) in the non-ICD group. ICD patients were significantly younger (median 67 vs. 74 years) and were significantly less often female (18.1% vs. 27.7%, p < 0.005 for both). Advanced extraction tools were used significantly more often in the ICD group (73.2% vs. 37.5%, p < 0.001), but there were no significant differences in the successful removal (98.8% vs. 99.2%) or complications (4.7% vs. 3.1%) between the groups (p > 0.2 for both). Discussion: Using the stepwise approach, overall procedural success was high and complication rate was low in a high-volume centre. In patients with a high energy lead, the TLE procedure was more complex, but outcome was similar to comparator patients