113 research outputs found

    Femoral neck fracture following intramedullary nailing with misplacement of an end cup: report of two cases

    Get PDF
    Femoral neck fracture is an unusual complication of intramedullary fixation of a broken femur. We report on two cases of femoral neck fractures attributed to misplacement of an end cup and subsequent invasive maneuvers in an effort to remove it. Iatrogenic fractures of the femoral neck during or after intramedullary nailing are reported in the medical literature. Authors associate it with many possible technical mistakes performed during the procedure, yet no complications after missed end cup placement were noted. We suggest that the fractures described below were a consequence of injury to the vascular supply and bone stock of the initially intact femoral neck

    Regeneration of the Semitendinosus Tendon Harvested for Anterior Cruciate Ligament Reconstruction. Evaluation Using Ultrasonography

    Get PDF
    In a prospective study, 40 consecutive patients who underwent anterior cruciate ligament reconstruction with doubled semitendinosus and gracilis tendon autografts were examined pre- and postoperatively by ultrasound to investigate the anatomy of the donor site before and after the harvest of the tendons. The patients underwent ultrasonography at 2 weeks and 1, 2, 3, 6, 12, 18, and 24 months postoperatively. A total of 298 postoperative sonographic evaluations were performed. The semitendinosus tendon was imaged in the sagittal and axial planes: structure and margins were evaluated with the sagittal views; thickness and width were measured with the axial views. In all cases the following sequence of healing was documented: 2 weeks after surgery the semitendinosus tendon site was occupied by an area of increased thickness and decreased echogenicity, suggesting the presence of traumatic edema of the soft tissue surrounding the tenotomy. At 1 month, an irregular hypoechoic structure appeared in a near-anatomic position; at 2 months after surgery, thickness, width, and cross-sectional area of this structure were significantly greater than preoperatively. The amount of regenerated tissue increased up to that seen in the tissue of the 6-month examinations, which also showed a more uniform echostructure. The scans performed at 1 year showed distinct edges and reduction in thickness and width. At 18 and 24 months the echogenicity of the structure occupying the donor site was very similar to that of the normal semitendinosus tendon. However, this structure was clearly identified about 4 cm proximal to the pes anserinus, revealing a more proximal insertion of the regenerated semitendinosus tendon

    Isolated thumb carpometacarpal joint dislocation: a case report and review of the literature

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Isolated thumb carpometacarpal dislocation is a rare injury pattern and the optimal treatment option is still controversial.</p> <p>Case Description</p> <p>We present a 27-year-old basketball player who underwent an isolated dorsal dislocation of the thumb carpometacarpal joint after a fall. The dislocation was successfully reduced by closed means but the joint was found to be grossly unstable. Due to inherent instability, repair of the ruptured dorsoradial ligament and joint capsule was performed.</p> <p>The ligament was detached from its proximal insertion into trapezium and subsequently stabilized via suture anchors. The torn capsule was repaired in an end-to-end fashion and immobilization of the joint was applied for 6 weeks.</p> <p>Results</p> <p>At 3-year follow up evaluation the patient was pain free and returned to his previous level of activity. No restriction of carpometacrpal movements or residual instability was noticed. Radiographic examination showed normal joint alignment and no signs of subluxation or early osteoarthritis.</p> <p>Conclusion</p> <p>Surgical stabilization of the dorsal capsuloligamentous complex may be considered the selected treatment option in isolated carpometacarpal joint dislocations, that remain unstable after closed reduction in young and high demand patients.</p> <p><b>Level of Clinical Evidence: </b>Level IV</p

    Spin-valley phase diagram of the two-dimensional metal-insulator transition

    Full text link
    Using symmetry breaking strain to tune the valley occupation of a two-dimensional (2D) electron system in an AlAs quantum well, together with an applied in-plane magnetic field to tune the spin polarization, we independently control the system's valley and spin degrees of freedom and map out a spin-valley phase diagram for the 2D metal-insulator transition. The insulating phase occurs in the quadrant where the system is both spin- and valley-polarized. This observation establishes the equivalent roles of spin and valley degrees of freedom in the 2D metal-insulator transition.Comment: 4 pages, 2 figure

    Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Primary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces.</p> <p>A controlled laboratory study was designed to test the primary stability of ACL tendinous grafts in the tibial tunnel. The correlation between resistance to traction forces and the cross-section and length of the screw was studied.</p> <p>Methods</p> <p>The tibial phase of ACL reconstruction was performed in forty porcine tibias using digital flexor tendons of the same animal. An 8 mm tunnel was drilled in each specimen and two looped tendons placed as graft. Specimens were divided in five groups according to the diameter and length of the screw used for fixation. Wedge interference screws were used. Longitudinal traction was applied to the graft with a Servohydraulic Fatigue System. Load and displacement were controlled and analyzed.</p> <p>Results</p> <p>The mean loads to failure for each group were 295,44 N (Group 1; 9 × 23 screw), 564,05 N (Group 2; 9 × 28), 614,95 N (Group 3; 9 × 35), 651,14 N (Group 4; 10 × 28) and 664,99 (Group 5; 10 × 35). No slippage of the graft was observed in groups 3, 4 and 5. There were significant differences in the load to failure among groups (ANOVA/P < 0.001).</p> <p>Conclusions</p> <p>Longer and wider interference screws provide better fixation in tibial ACL graft fixation. Short screws (23 mm) do not achieve optimal fixation and should be implanted only with special requirements.</p

    Iron Behaving Badly: Inappropriate Iron Chelation as a Major Contributor to the Aetiology of Vascular and Other Progressive Inflammatory and Degenerative Diseases

    Get PDF
    The production of peroxide and superoxide is an inevitable consequence of aerobic metabolism, and while these particular "reactive oxygen species" (ROSs) can exhibit a number of biological effects, they are not of themselves excessively reactive and thus they are not especially damaging at physiological concentrations. However, their reactions with poorly liganded iron species can lead to the catalytic production of the very reactive and dangerous hydroxyl radical, which is exceptionally damaging, and a major cause of chronic inflammation. We review the considerable and wide-ranging evidence for the involvement of this combination of (su)peroxide and poorly liganded iron in a large number of physiological and indeed pathological processes and inflammatory disorders, especially those involving the progressive degradation of cellular and organismal performance. These diseases share a great many similarities and thus might be considered to have a common cause (i.e. iron-catalysed free radical and especially hydroxyl radical generation). The studies reviewed include those focused on a series of cardiovascular, metabolic and neurological diseases, where iron can be found at the sites of plaques and lesions, as well as studies showing the significance of iron to aging and longevity. The effective chelation of iron by natural or synthetic ligands is thus of major physiological (and potentially therapeutic) importance. As systems properties, we need to recognise that physiological observables have multiple molecular causes, and studying them in isolation leads to inconsistent patterns of apparent causality when it is the simultaneous combination of multiple factors that is responsible. This explains, for instance, the decidedly mixed effects of antioxidants that have been observed, etc...Comment: 159 pages, including 9 Figs and 2184 reference
    corecore