47 research outputs found

    Evaluation of the Becton-Dickinson rapid serum tube: Does it provide a suitable alternative to lithium heparin plasma tubes?

    Get PDF
    Background: Obtaining a suitable specimen for analysis in a timely manner is pivotal in clinical chemistry service provision. Serum is recognized as the preferred specimen for most assays, but because of time constraints for completion of clotting and an increasing number of patients on anti-coagulant therapy, latent clotting or no clotting is an outcome which can lead to errors and delay in delivery of critical results. Although lithium heparin plasma has unique problems, it has become an alternative in hospital-based laboratories. Methods: The Becton-Dickinson (BD) rapid serum tube (RST) was evaluated in a hospital environment using a total of 53 participants, both healthy and anticoagulated, for 31 analytes against BD PST II and BD SST II tubes measured with Beckman DxC800 and DxI800 analyzers. Results: Most results from the RST tube were comparable with those from the SST II tube. Potassium results were closer to the PST II plasma concentrations. Incomplete and latent clotting was encountered in the RST specimens from participants (cardiac and dialysis) who had received a total of >7000 units of heparin [activated partial thromboplastin time (APTT) >150 s], warfarin/heparin combination, and specimens from cardiac surgery patients who had received a total of >25, 000 units of heparin (APTT >200 s) at the time of collection of specimens. Conclusions: The RST tube provides a suitable alternative to lithium heparin plasma tubes for most patients in a hospital environment. However, latent clotting continued to occur in specimens collected from participants who had received high concentrations of anticoagulants

    Does electronic clinical microbiology results reporting influence medical decision making: a pre- and post-interview study of medical specialists

    Get PDF
    Background: Clinicians view the accuracy of test results and the turnaround time as the two most important service aspects of the clinical microbiology laboratory. Because of the time needed for the culturing of infectious agents, final hardcopy culture results will often be available too late to have a significant impact on early antimicrobial therapy decisions, vital in infectious disease management. The clinical microbiologist therefore reports to the clinician clinically relevant preliminary results at any moment during the diagnostic process, mostly by telephone. Telephone reporting is error prone, however. Electronic reporting of culture results instead of reporting on paper may shorten the turnaround time and may ensure correct communication of results. The purpose of this study was to assess the impact of the implementation of electronic reporting of final microbiology results on medical decision making. Methods. In a pre- and post-interview study using a semi-structured design we asked medical specialists in our hospital about their use and appreciation of clinical microbiology results reporting before and after the implementation of an electronic reporting system. Results: Electronic reporting was highly appreciated by all interviewed clinicians. Major advantages were reduction of hardcopy handling and the possibility to review results in relation to other patient data. Use and meaning of microbiology reports differ significantly between medical specialties. Most clinicians need preliminary results for therapy decisions quickly. Therefore, after the implementation of electronic reporting, telephone consultation between clinician and microbiologist remained the key means of communication. Conclusions: Overall, electronic reporting increased the workflow efficiency of the medical specialists, but did not have an impact on their decision-making

    Medical Mobile Robotics: An Industry Update

    No full text
    corecore