176 research outputs found

    Asian-Specific total knee system: 5-14 year follow-up study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Knee size and body size differ in Asians compared with Caucasians. Nevertheless, many total knee arthroplasty (TKA) prostheses used worldwide are made for Western Caucasian subjects. As a result, an Asian's knee might not fit these prostheses. We studied the Flexible Nichidai Knee (FNK) system, a new model of TKA for Asian patients. The purpose of this report is to investigate the outcomes of this prosthesis retrospectively.</p> <p>Methods</p> <p>We investigated 1055 primary TKAs in 595 patients who underwent FNK for osteoarthritis (OA) in Japan and were followed for > 5 years. The knee score and function score were used for clinical evaluation. We examined the range of motion (ROM) preoperatively and at final follow-up and radiographic assessments. In addition, postoperative complications were investigated. A survivorship analysis was also conducted using two endpoints: revision for any reason and aseptic failure.</p> <p>Results</p> <p>890 knees in 502 patients were available for study (follow-up rate of 96.0%). The mean follow-up term was 8.3 years (range, 5.0-14.1 years). The knee and function score significantly improved from 41.3 to 90.3 and from 39.1 to 76.2 points, respectively (p < 0.001). The mean ROM in FNK posterior cruciate retaining (CR) type and FNK posterior-stabilized (PS) type ameliorated significantly from 107.8° and 95.6° to 110.7° and 110.4°, respectively (p < 0.01). Ten knees underwent revision surgery (infection in 3 cases, instability in 2, loosening in 2, and non-union of femoral supracondylar fracture, severe pain, and recurrent hemarthrosis in 1 each). The survivorship rate was 99.4% (95% CI, 99.0-99.8) at 5 years (n = 952 patients at risk) and 96.2% (95% CI, 91.9-100) at 12.5 years (n = 49 patients at risk).</p> <p>Conclusion</p> <p>The FNK prosthesis for Asians achieved excellent mid- to long-term survivorship and clinical results.</p

    Computational Modelling of Patella Femoral Kinematics During Gait Cycle and Experimental Validation

    Get PDF
    The effect of loading and boundary conditions on patellar mechanics is significant due to the complications arising in patella femoral joints during total knee replacements. To understand the patellar mechanics with respect to loading and motion, a computational model representing the patella femoral joint was developed and validated against experimental results. The computational model was created in IDEAS NX and simulated in MSC ADAMS/VIEW software. The results obtained in the form of internal external rotations and anterior posterior displacements for a new and experimentally simulated specimen for patella femoral joint under standard gait condition were compared with experimental measurements performed on the Leeds ProSim knee simulator. A good overall agreement between the computational prediction and the experimental data was obtained for patella femoral kinematics. Good agreement between the model and the past studies was observed when the ligament load was removed and the medial lateral displacement was constrained. The model is sensitive to ±5 % change in kinematics, frictional, force and stiffness coefficients and insensitive to time step

    Cost effectiveness of total knee arthroplasty from a health care providers' perspective before and after introduction of an interdisciplinary clinical pathway - is investment always improvement?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Total knee arthroplasty (TKA) is an effective, but also cost-intensive health care intervention for end stage osteoarthritis. This investigation was designed to evaluate the cost-effectiveness of TKA before versus after introduction of an interdisciplinary clinical pathway from a University Orthopedic Surgery Department's cost perspective as an interdisciplinary full service health care provider.</p> <p>Methods</p> <p>A prospective trial recruited two sequential cohorts of 132 and 128 consecutive patients, who were interviewed by means of the WOMAC questionnaire. Direct process costs from the health care providers' perspective were estimated according to the German DRG calculation framework. The health economic evaluation was based on margiual cost-effectveness ratios (MCERs); an individual marginal cost effectiveness relation ≤ 100 € per % WOMAC index increase was considered as primary endpoint of the confirmatory cohort comparison. The interdisciplinary clinical pathway under consideration primarily consisted of a voluntary preoperative personal briefing of patients concerning postoperatively expectable progess in health status and optimum use of walking aids after surgery. All patients were supplied with written information on these topics, attendance of the personal briefing also included preoperative training for postoperative mobilisation by the Department's physiotherapeutic staff.</p> <p>Results</p> <p>An individual marginal cost effectiveness relation ≤ 100 €/% WOMAC index increase was found in 38% of the patients in the pre pathway implementation cohort versus in 30% of the post pathway implementation cohort (Fisher p = 0.278). Both cohorts showed substantial improvement in WOMAC scores (39 versus 35% in median), whereas the cohort did not differ significantly in the median WOMAC score before surgery (41% for the pre pathway cohort versus 44% for the post pathway cohort). Despite a locally significant decrease in costs (4303 versus 4194 € in median), the individual cost/benefit relation became worse after introduction of the pathway: for the first cohort the MCER was estimated 108 € per gained % WOMAC index increase (86 - 150 €/%) versus 118 €/% WOMAC gain (93 - 173 €/%) in the second cohort after pathway implementation. In summary, the proposed critical pathway for TKA could be shown to be significantly cost efficient, but not cost effective concerning functional outcome, when the above individual marginal cost effectiveness criterion was concentrated on.</p> <p>Conclusions</p> <p>The introduction of an interdisciplinary clinical pathway does not necessarily improve patient related outcomes. On the contrary, cost effectiveness from the health care providers' perspective may even turn out remarkably reduced in the setting considered here (functional outcome assessment after treatment by a full service health care provider).</p

    Surface pretreatment for prolonged survival of cemented tibial prosthesis components: full- vs. surface-cementation technique

    Get PDF
    BACKGROUND: One of few persisting problems of cemented total knee arthroplasty (TKA) is aseptic loosening of tibial component due to degradation of the interface between bone cement and metallic tibial shaft component, particularly for surface cemented tibial components. Surface cementation technique has important clinical meaning in case of revision and for avoidance of stress shielding. Degradation of the interface between bone cement and bone may be a secondary effect due to excessive crack formation in bone cement starting at the opposite metallic surface. METHODS: This study was done to prove crack formation in the bone cement near the metallic surface when this is not coated. We propose a newly developed coating process by PVD layering with SiO(x )to avoid that crack formation in the bone cement. A biomechanical model for vibration fatigue test was done to simulate the physiological and biomechanical conditions of the human knee joint and to prove excessive crack formation. RESULTS: It was found that coated tibial components showed a highly significant reduction of cement cracking near the interface metal/bone cement (p < 0.01) and a significant reduction of gap formation in the interface metal-to-bone cement (p < 0.05). CONCLUSION: Coating dramatically reduces hydrolytic- and stress-related crack formation at the prosthesis interface metal/bone cement. This leads to a more homogenous load transfer into the cement mantle which should reduce the frequency of loosening in the interfaces metal/bone cement/bone. With surface coating of the tibial component it should become possible that surface cemented TKAs reveal similar loosening rates as TKAs both surface and stem cemented. This would be an important clinical advantage since it is believed that surface cementing reduces metaphyseal bone loss in case of revision and stress shielding for better bone health

    A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery

    Get PDF
    Rotation of the femoral component in total knee arthroplasty (TKA) is of high importance in respect of the balancing of the knee and the patellofemoral joint. Though it is shown that computer assisted surgery (CAOS) improves the anteroposterior (AP) alignment in TKA, it is still unknown whether navigation helps in finding the accurate rotation or even improving rotation. Therefore the aim of our study was to evaluate the postoperative femoral component rotation on computed tomography (CT) with the intraoperative data of the navigation system. In 20 navigated TKAs the difference between the intraoperative stored rotation data of the femoral component and the postoperative rotation on CT was measured using the condylar twist angle (CTA). This is the angle between the epicondylar axis and the posterior condylar axis. Statistical analysis consisted of the intraclass correlation coefficient (ICC) and Bland-Altman plot. The mean intraoperative rotation CTA based on CAOS was 3.5° (range 2.4–8.6°). The postoperative CT scan showed a mean CTA of 4.0° (1.7–7.2). The ICC between the two observers was 0.81, and within observers this was 0.84 and 0.82, respectively. However, the ICC of the CAOS CTA versus the postoperative CT CTA was only 0.38. Though CAOS is being used for optimising the position of a TKA, this study shows that the (virtual) individual rotational position of the femoral component using a CAOS system is significantly different from the position on a postoperative CT scan
    corecore