236 research outputs found

    Testing the performance of a blind burst statistic

    Full text link
    In this work we estimate the performance of a method for the detection of burst events in the data produced by interferometric gravitational wave detectors. We compute the receiver operating characteristics in the specific case of a simulated noise having the spectral density expected for Virgo, using test signals taken from a library of possible waveforms emitted during the collapse of the core of Type II Supernovae.Comment: 8 pages, 6 figures, Talk given at the GWDAW2002 worksho

    Calcineurin gamma catalytic subunit ppp3cc inhibition by mir-200c-3p affects apoptosis in epithelial ovarian cancer

    Get PDF
    Epithelial ovarian cancer (EOC) outpaces all the other forms of the female reproductive system malignancies. MicroRNAs have emerged as promising predictive biomarkers to therapeutic treatments as their expression might characterize the tumor stage or grade. In EOC, miR-200c is considered a master regulator of oncogenes or tumor suppressors. To investigate novel miR-200c-3p target genes involved in EOC tumorigenesis, we evaluated the association between this miRNA and the mRNA expression of several potential target genes by RNA-seq data of both 46 EOC cell lines from Cancer Cell line Encyclopedia (CCLE) and 456 EOC patient bio-specimens from The Cancer Genome Atlas (TCGA). Both analyses showed a significant anticorrelation between miR-200c-3p and the protein phosphatase 3 catalytic subunit Îł of calcineurin (PPP3CC) levels involved in the apoptosis pathway. Quantitative mRNA expression analysis in patient biopsies confirmed the inverse correlation between miR-200c-3p and PPP3CC levels. In vitro regulation of PPP3CC expression through miR-200c-3p and RNA interference technology led to a concomitant modulation of BCL2- and p-AKT-related pathways, suggesting the tumor suppressive role of PPP3CC in EOC. Our results suggest that inhibition of high expression of miR-200c-3p in EOC might lead to overexpression of the tumor suppressor PPP3CC and subsequent induction of apoptosis in EOC patients

    Discovery of chemotherapy-associated ovarian cancer antigens by interrogating memory T cells

    Get PDF
    According to the immunogenic cell death hypothesis, clinical chemotherapy treatments may result in CD8(+) and CD4(+) T-cell responses against tumor cells. To discover chemotherapy-associated antigens (CAAs), T cells derived from ovarian cancer (OC) patients (who had been treated with appropriate chemotherapy protocols) were interrogated with proteins isolated from primary OC cells. We screened for immunogenicity using two-dimensional electrophoresis gel-eluted OC proteins. Only the selected immunogenic antigens were molecularly characterized by mass-spectrometry-based analysis. Memory T cells that recognized antigens associated with apoptotic (but not live) OC cells were correlated with prolonged survival in response to chemotherapy, supporting the model of chemotherapy-induced apoptosis as an adjuvant of anti-tumor immunity. The strength of both memory CD4(+) and CD8(+) T cells producing either IFN- or IL-17 in response to apoptotic OC antigens was also significantly greater in Responders to chemotherapy than in nonresponders. Immunogenicity of some of these antigens was confirmed using recombinant proteins in an independent set of patients. The T-cell interrogation system represents a strategy of reverse tumor immunology that proposes to identify CAAs, which may then be validated as possible prognostic tumor biomarkers or cancer vaccines

    Low loss coatings for the VIRGO large mirrors

    Get PDF
    présentée par L. PinardThe goal of the VIRGO program is to build a giant Michelson type interferometer (3 kilometer long arms) to detect gravitational waves. Large optical components (350 mm in diameter), having extremely low loss at 1064 nm, are needed. Today, the Ion beam Sputtering is the only deposition technique able to produce optical components with such performances. Consequently, a large ion beam sputtering deposition system was built to coat large optics up to 700 mm in diameter. The performances of this coater are described in term of layer uniformity on large scale and optical losses (absorption and scattering characterization). The VIRGO interferometer needs six main mirrors. The first set was ready in June 2002 and its installation is in progress on the VIRGO site (Italy). The optical performances of this first set are discussed. The requirements at 1064 nm are all satisfied. Indeed, the absorption level is close to 1 ppm (part per million), the scattering is lower than 5 ppm and the R.M.S. wavefront of these optics is lower than 8 nm on 150 mm in diameter. Finally, some solutions are proposed to further improve these performances, especially the absorption level (lower than 0.1 ppm) and the mechanical quality factor Q of the mirrors (thermal noise reduction)

    Search for non-Gaussian events in the data of the VIRGO E4 engineering run

    Get PDF
    International audienc
    • 

    corecore