3,999 research outputs found
Characterisation of Hybrid Pixel Detectors with capacitive charge division
In order to fully exploit the physics potential of the future high energy e+
e- linear collider, a Vertex Tracker providing high resolution track
reconstruction is required. Hybrid pixel sensors are an attractive technology
due to their fast read-out capabilities and radiation hardness. A novel pixel
detector layout with interleaved cells between the readout nodes has been
developed to improve the single point resolution. The results of the
characterisation of the first processed prototypes are reported.Comment: 5 pages, 2 figures, presented at LCWS2000, Linear Collider Workshop,
October 24-28 2000, Fermi National Accelerator Laboratory, Batavia, Illinois,
U.S.A. Proceedings to be published by the American Institute of Physic
Insulin-like growth factor-1 receptor inhibitor, AMG-479, in cetuximab-refractory head and neck squamous cell carcinoma
Background Recurrent head and neck squamous cell carcinoma (HNSCC) remains a difficult cancer to treat. Here, we describe a patient with HNSCC who had complete response to methotrexate (MTX) after progressing on multiple cytotoxic agents, cetuximab, and AMG-479 (monoclonal antibody against insulin-like growth factor-1 receptor [IGF-1R]). Methods The clinical information was collected by a retrospective medical record review under an Institutional Review Board-approved protocol. From 4 tumors and 2 normal mucosal epithelia, global gene expression, and IGF-1R and dihydrofolate reductase (DHFR) protein levels were determined. Results Effective target inhibition in the tumor was confirmed by the decreased protein levels of total and phospho-IGF-1R after treatment with AMG-479. Decreased level of DHFR and conversion of a gene expression profile associated with cetuximab-resistance to cetuximab-sensitivity were also observed. Conclusion This suggests that the combination of AMG-479 and MTX or cetuximab may be a promising therapeutic approach in refractory HNSCC
Classification of singular Q-homology planes. I. Structure and singularities
A Q-homology plane is a normal complex algebraic surface having trivial
rational homology. We obtain a structure theorem for Q-homology planes with
smooth locus of non-general type. We show that if a Q-homology plane contains a
non-quotient singularity then it is a quotient of an affine cone over a
projective curve by an action of a finite group respecting the set of lines
through the vertex. In particular, it is contractible, has negative Kodaira
dimension and only one singular point. We describe minimal normal completions
of such planes.Comment: improved results from Ph.D. thesis (University of Warsaw, 2009), 25
pages, to appear in Israel J. Mat
The Straw Tube Trackers of the PANDA Experiment
The PANDA experiment will be built at the FAIR facility at Darmstadt
(Germany) to perform accurate tests of the strong interaction through bar pp
and bar pA annihilation's studies. To track charged particles, two systems
consisting of a set of planar, closed-packed, self-supporting straw tube layers
are under construction. The PANDA straw tubes will have also unique
characteristics in term of material budget and performance. They consist of
very thin mylar-aluminized cathodes which are made self-supporting by means of
the operation gas-mixture over-pressure. This solution allows to reduce at
maximum the weight of the mechanical support frame and hence the detector
material budget. The PANDA straw tube central tracker will not only reconstruct
charged particle trajectories, but also will help in low momentum (< 1 GeV)
particle identification via dE/dx measurements. This is a quite new approach
that PANDA tracking group has first tested with detailed Monte Carlo
simulations, and then with experimental tests of detector prototypes. This
paper addresses the design issues of the PANDA straw tube trackers and the
performance obtained in prototype tests.Comment: 7 pages,16 figure
Study of B meson decays to three-body charmless hadronic final states
We report results of a study of charmless B meson decays to three-body KPiPi,
KKPi and KKK final states. Measurements of branching fractions for B decays to
K+0Pi+Pi-, K+K+K-, K0K+K-, KsKsK+ and KsKsKs final states are presented. The
decays B0=>K0K+K-, B+=>KsKsK+ and B0=>KsKsKs are observed for the first time.
We also report evidence for B+=>K+K-Pi+ decay. For the three-body final states
K0K+K-, KsKsPi+, K+K+Pi- and K-Pi+Pi+ 90% confidence level upper limits are
reported. Finally, we discuss the possibility of using the three-body
B0=>KsK+K- decay for CP violation studies. The results are obtained with a 78
fb^-1 data sample collected at the Y(4S) resonance by the Belle detector
operating at the KEKB asymmetric energy e+e- collider.Comment: 15 pages, 6 figures. To be submitted to PR
Observation of B+->Lambda_c+Lambda_c-K+ and B0->Lambda_c+Lambda_c^-K0 decays
We report first measurements of the doubly charmed baryonic B decays
B->Lambda_c+Lambda_c-K. The B+->Lambda_c+Lambda_c-K+ decay is observed with a
branching fraction of (6.5+1.0-0.9+-1.1+-3.4)x10^{-4} and a statistical
significance of 15.4sigma. The B0->Lambda_c+Lambda_c-K0 decay is observed with
a branching fraction of (7.9+2.9-2.3+-1.2+-4.2)x10^{-4} and a statistical
significance of 6.6sigma. The branching fraction errors are statistical,
systematic, and the error resulting from the uncertainty of Lambda_c+->pK-pi+
decay branching fraction. The analysis is based on 357fb-1 of data accumulated
at the Y(4S) resonance with the Belle detector at the KEKB asymmetric e+e-
collider.Comment: 10 pages, 3 figure
Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
Recent tests of a single module of the Jagiellonian Positron Emission
Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips
have proven its applicability for the detection of annihilation quanta (0.511
MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved
resolution is almost by a factor of two better with respect to the current
TOF-PET detectors and it can still be improved since, as it is shown in this
article, the intrinsic limit of time resolution for the determination of time
of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much
lower. As the major point of the article, a method allowing to record
timestamps of several photons, at two ends of the scintillator strip, by means
of matrix of silicon photomultipliers (SiPM) is introduced. As a result of
simulations, conducted with the number of SiPM varying from 4 to 42, it is
shown that the improvement of timing resolution saturates with the growing
number of photomultipliers, and that the 2 x 5 configuration at two ends
allowing to read twenty timestamps, constitutes an optimal solution. The
conducted simulations accounted for the emission time distribution, photon
transport and absorption inside the scintillator, as well as quantum efficiency
and transit time spread of photosensors, and were checked based on the
experimental results. Application of the 2 x 5 matrix of SiPM allows for
achieving the coincidence resolving time in positron emission tomography of
0.170 ns for 15 cm axial field-of-view (AFOV) and 0.365 ns
for 100 cm AFOV. The results open perspectives for construction of a
cost-effective TOF-PET scanner with significantly better TOF resolution and
larger AFOV with respect to the current TOF-PET modalities.Comment: To be published in Phys. Med. Biol. (26 pages, 17 figures
- …