3,999 research outputs found

    Characterisation of Hybrid Pixel Detectors with capacitive charge division

    Get PDF
    In order to fully exploit the physics potential of the future high energy e+ e- linear collider, a Vertex Tracker providing high resolution track reconstruction is required. Hybrid pixel sensors are an attractive technology due to their fast read-out capabilities and radiation hardness. A novel pixel detector layout with interleaved cells between the readout nodes has been developed to improve the single point resolution. The results of the characterisation of the first processed prototypes are reported.Comment: 5 pages, 2 figures, presented at LCWS2000, Linear Collider Workshop, October 24-28 2000, Fermi National Accelerator Laboratory, Batavia, Illinois, U.S.A. Proceedings to be published by the American Institute of Physic

    Insulin-like growth factor-1 receptor inhibitor, AMG-479, in cetuximab-refractory head and neck squamous cell carcinoma

    Get PDF
    Background Recurrent head and neck squamous cell carcinoma (HNSCC) remains a difficult cancer to treat. Here, we describe a patient with HNSCC who had complete response to methotrexate (MTX) after progressing on multiple cytotoxic agents, cetuximab, and AMG-479 (monoclonal antibody against insulin-like growth factor-1 receptor [IGF-1R]). Methods The clinical information was collected by a retrospective medical record review under an Institutional Review Board-approved protocol. From 4 tumors and 2 normal mucosal epithelia, global gene expression, and IGF-1R and dihydrofolate reductase (DHFR) protein levels were determined. Results Effective target inhibition in the tumor was confirmed by the decreased protein levels of total and phospho-IGF-1R after treatment with AMG-479. Decreased level of DHFR and conversion of a gene expression profile associated with cetuximab-resistance to cetuximab-sensitivity were also observed. Conclusion This suggests that the combination of AMG-479 and MTX or cetuximab may be a promising therapeutic approach in refractory HNSCC

    Classification of singular Q-homology planes. I. Structure and singularities

    Full text link
    A Q-homology plane is a normal complex algebraic surface having trivial rational homology. We obtain a structure theorem for Q-homology planes with smooth locus of non-general type. We show that if a Q-homology plane contains a non-quotient singularity then it is a quotient of an affine cone over a projective curve by an action of a finite group respecting the set of lines through the vertex. In particular, it is contractible, has negative Kodaira dimension and only one singular point. We describe minimal normal completions of such planes.Comment: improved results from Ph.D. thesis (University of Warsaw, 2009), 25 pages, to appear in Israel J. Mat

    The Straw Tube Trackers of the PANDA Experiment

    Full text link
    The PANDA experiment will be built at the FAIR facility at Darmstadt (Germany) to perform accurate tests of the strong interaction through bar pp and bar pA annihilation's studies. To track charged particles, two systems consisting of a set of planar, closed-packed, self-supporting straw tube layers are under construction. The PANDA straw tubes will have also unique characteristics in term of material budget and performance. They consist of very thin mylar-aluminized cathodes which are made self-supporting by means of the operation gas-mixture over-pressure. This solution allows to reduce at maximum the weight of the mechanical support frame and hence the detector material budget. The PANDA straw tube central tracker will not only reconstruct charged particle trajectories, but also will help in low momentum (< 1 GeV) particle identification via dE/dx measurements. This is a quite new approach that PANDA tracking group has first tested with detailed Monte Carlo simulations, and then with experimental tests of detector prototypes. This paper addresses the design issues of the PANDA straw tube trackers and the performance obtained in prototype tests.Comment: 7 pages,16 figure

    Study of B meson decays to three-body charmless hadronic final states

    Full text link
    We report results of a study of charmless B meson decays to three-body KPiPi, KKPi and KKK final states. Measurements of branching fractions for B decays to K+0Pi+Pi-, K+K+K-, K0K+K-, KsKsK+ and KsKsKs final states are presented. The decays B0=>K0K+K-, B+=>KsKsK+ and B0=>KsKsKs are observed for the first time. We also report evidence for B+=>K+K-Pi+ decay. For the three-body final states K0K+K-, KsKsPi+, K+K+Pi- and K-Pi+Pi+ 90% confidence level upper limits are reported. Finally, we discuss the possibility of using the three-body B0=>KsK+K- decay for CP violation studies. The results are obtained with a 78 fb^-1 data sample collected at the Y(4S) resonance by the Belle detector operating at the KEKB asymmetric energy e+e- collider.Comment: 15 pages, 6 figures. To be submitted to PR

    Observation of B+->Lambda_c+Lambda_c-K+ and B0->Lambda_c+Lambda_c^-K0 decays

    Full text link
    We report first measurements of the doubly charmed baryonic B decays B->Lambda_c+Lambda_c-K. The B+->Lambda_c+Lambda_c-K+ decay is observed with a branching fraction of (6.5+1.0-0.9+-1.1+-3.4)x10^{-4} and a statistical significance of 15.4sigma. The B0->Lambda_c+Lambda_c-K0 decay is observed with a branching fraction of (7.9+2.9-2.3+-1.2+-4.2)x10^{-4} and a statistical significance of 6.6sigma. The branching fraction errors are statistical, systematic, and the error resulting from the uncertainty of Lambda_c+->pK-pi+ decay branching fraction. The analysis is based on 357fb-1 of data accumulated at the Y(4S) resonance with the Belle detector at the KEKB asymmetric e+e- collider.Comment: 10 pages, 3 figure

    Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph

    Full text link
    Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the 2 x 5 configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the 2 x 5 matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of \approx 0.170 ns for 15 cm axial field-of-view (AFOV) and \approx 0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.Comment: To be published in Phys. Med. Biol. (26 pages, 17 figures
    corecore