245 research outputs found

    Biological variation: back to basics

    Get PDF
    Biological variation: back to basics

    An approach for estimating measurement uncertainty in medical laboratories using data from long-term quality control and external quality assessment schemes

    Get PDF
    The present study was prompted by the ISO 15189 requirements that medical laboratories should estimate measurement uncertainty (MU)

    Verification of examination procedures in clinical laboratory for imprecision, trueness and diagnostic accuracy according to ISO 15189:2012: a pragmatic approach

    Get PDF
    Background The International Standard ISO 15189 is recognized as a valuable guide in ensuring high quality clinical laboratory services and promoting the harmonization of accreditation programmes in laboratory medicine. Examination procedures must be verified in order to guarantee that their performance characteristics are congruent with the intended scope of the test. The aim of the present study was to propose a practice model for implementing procedures employed for the verification of validated examination procedures already used for at least 2 years in our laboratory, in agreement with the ISO 15189 requirement at the Section 5.5.1.2. Methods In order to identify the operative procedure to be used, approved documents were identified, together with the definition of performance characteristics to be evaluated for the different methods; the examination procedures used in laboratory were analyzed and checked for performance specifications reported by manufacturers. Then, operative flow charts were identified to compare the laboratory performance characteristics with those declared by manufacturers. Results The choice of performance characteristics for verification was based on approved documents used as guidance, and the specific purpose tests undertaken, a consideration being made of: imprecision and trueness for quantitative methods; diagnostic accuracy for qualitative methods; imprecision together with diagnostic accuracy for semi-quantitative methods. Conclusions The described approach, balancing technological possibilities, risks and costs and assuring the compliance of the fundamental component of result accuracy, appears promising as an easily applicable and flexible procedure helping laboratories to comply with the ISO 15189 requirements

    SARS-CoV-2 Infection in Spondyloarthritis Patients Treated With Biotechnological Drugs: A Study on Serology

    Get PDF
    ObjectiveSerology could help to define the real extent of SARS-CoV-2 diffusion, especially in individuals considered at higher risk of COVID-19, such as spondyloarthritis (SpA) patients undergoing immunosuppressant. Our aim was to detect, by serology, previous SARS-CoV-2 contact in SpA, compared to health care workers (HCW), and healthy controls.MethodsSera from consecutive patients affected by SpA undergoing cytokine-targeted therapy, HCW and healthy controls from 2015 were analysed through chemiluminescent analytical system for the presence of IgG and IgM anti-SARS-CoV-2. Positive patients (IgM or IgG, or both) additionally underwent real-time Polymerase-Chain-Reaction (RT-PCR) to test for active infection. Serology was repeated at 3-months in SpA. Data across 3 groups were compared by Kruskal Wallis/Chi-square, and between 2 groups by Wilcoxon rank test/Chi-Square. P ≤ 0.05 were considered significant.Results200 SpA, 95 HCW and 101 controls were recruited. Positive serology was found in 25(12.5%) SpA, 8(8.4%) HCW, 0(0%) controls (p=0.001). SpA patients with positive serology more frequently reported COVID-19-like symptoms than those with negative serology (20% vs. 4%, p=0.009) and 2 had COVID-19 as confirmed by RT-PCR, non severe. No HCW reported symptoms or had positive RT-PCR. In SpA patients, at 3 months, mean IgM titres decreased from 2.76 ± 2.93 to 2.38 ± 2.95 (p=0.001), while IgG titres from 0.89 ± 3.25 to 0.31 ± 0.87 (p=ns).ConclusionsSerology revealed that exposure to SARS-CoV-2 in SpA patients and HCW was higher than expected based on reported symptoms. In SpA, anti-cytokine therapy could act as a protective factor for a severe disease course. However, a seroconversion was not observed at 3-months

    A new sampling device for faecal immunochemical testing: haemoglobin stability is still an open issue

    Get PDF
    Abstract Background: The detection of faecal occult blood is a fundamental step in making an early diagnosis of colorectal cancer. The aim of the present study was to evaluate the stability of haemoglobin in faeces collected with two sampling devices specific for faecal immunochemical testing (FOB Gold Tube Screen and FOB Gold Tube NG) that contain different preservative buffers (buffer H, BH, and buffer N, BN, respectively). Methods: Fifteen true positive faecal samples were collected with both devices. A pool from each sample was made. Each pool was portioned and stored at +4\ub0C, +21\ub0C and +32\ub0C for 10 days. One aliquot of each pool stored at each of the respective temperatures was tested at five time intervals between sampling and analysis. The same procedure was followed for three synthetic haemoglobin solutions in both buffers. Results: The percentage of cumulative faecal haemoglobin decrease (HbCD%) was evaluated. No significant difference was found between BH and BN in HbCD% at +4\ub0C (p=0.106); at +21\ub0C and +32\ub0C, HbCD% was lower in BH than in BN samples (p=0.002 and

    SMAD4 loss enables EGF, TGF\u3b21 and S100A8/A9 induced activation of critical pathways to invasion in human pancreatic adenocarcinoma cells

    Get PDF
    Epidermal Growth Factor (EGF) receptor overexpression, KRAS, TP53, CDKN2A and SMAD4 mutations characterize pancreatic ductal adenocarcinoma. This mutational landscape might influence cancer cells response to EGF, Transforming Growth Factor \u3b21 (TGF\u3b21) and stromal inflammatory calcium binding proteins S100A8/A9. We investigated whether chronic exposure to EGF modifies in a SMAD4-dependent manner pancreatic cancer cell signalling, proliferation and invasion in response to EGF, TGF\u3b21 and S100A8/A9. BxPC3, homozigously deleted (HD) for SMAD4, and BxPC3-SMAD4+ cells were or not stimulated with EGF (100 ng/mL) for three days. EGF pre-treated and non pretreated cells were stimulated with a single dose of EGF (100 ng/mL), TGF\u3b21 (0,02 ng/mL), S100A8/A9 (10 nM). Signalling pathways (Reverse Phase Protein Array and western blot), cell migration (Matrigel) and cell proliferation (XTT) were evaluated. SMAD4 HD constitutively activated ERK and Wnt/\u3b2-catenin, while inhibiting PI3K/AKT pathways. These effects were antagonized by chronic EGF, which increased p-BAD (anti-apoptotic) in response to combined TGF\u3b21 and S100A8/A9 stimulation. SMAD4 HD underlied the inhibition of NF-\u3baB and PI3K/AKT in response to TGF\u3b21 and S100A8/A9, which also induced cell migration. Chronic EGF exposure enhanced cell migration of both BxPC3 and BxPC3-SMAD4+, rendering the cells less sensitive to the other inflammatory stimuli. In conclusion, SMAD4 HD is associated with the constitutive activation of the ERK and Wnt/\u3b2-catenin signalling pathways, and favors the EGF-induced activation of multiple signalling pathways critical to cancer proliferation and invasion. TGF\u3b21 and S100A8/A9 mainly inhibit NF-\u3baB and PI3K/AKT pathways and, when combined, sinergize with EGF in enhancing anti-apoptotic p-BAD in a SMAD4-dependent manner

    Plasma and dried blood spot lysosphingolipids for the diagnosis of different sphingolipidoses: a comparative study.

    Get PDF
    Abstract Background Lysosphingolipids, the N-deacylated forms of sphingolipids, have been identified as potential biomarkers of several sphingolipidoses, such as Gaucher, Fabry, Krabbe and Niemann-Pick diseases and in GM1 and GM2 gangliosidoses. To date, different methods have been developed to measure various lysosphingolipids (LysoSLs) in plasma. Here, we present a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for a simultaneous quantification of LysoSLs (HexSph, LysoGb3, LysoGM1, LysoGM2, LysoSM and LysoSM509) in dried blood spot (DBS). This LC-MS/MS method was used to compare the levels of LysoSLs in DBS and plasma in both affected patients and healthy controls. Methods Lysosphingolipids were extracted from a 3.2 mm diameter DBS with a mixture of methanol:acetonitrile:water (80:15:5, v/v) containing internal stable isotope standards. Chromatographic separation was performed using a C18 column with a gradient of water and acetonitrile both with 0.1% formic acid in a total run time of 4 min. The compounds were detected in the positive ion mode electrospray ionization (ESI)-MS/MS by multiple reaction monitoring (MRM). Results The method was validated on DBS to demonstrate specificity, linearity, lowest limit of quantification, accuracy and precision. The reference ranges were determined in pediatric and adult populations. The elevated levels of LysoSLs were identified in Gaucher disease (HexSph), Fabry disease (LysoGb3), prosaposin deficiency (HexSph and LysoGb3) and Niemann-Pick disease types A/B and C (LysoSM and LysoSM509). The correlation in the levels between DBS and plasma was excellent for LysoGb3 and HexSph but poor for LysoSM and LysoSM509. Conclusions Despite the fact that plasma LysoSLs determination remains the gold standard, our LC-MS/MS method allows a rapid and reliable quantification of lysosphingolipids in DBS. The method is a useful tool for the diagnosis of different sphingolipidoses except for Niemann-Pick type C
    • …
    corecore