132 research outputs found

    Influence of bone density on implant stability parameters and implant success: a retrospective clinical study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of the present clinical study was to determine the local bone density in dental implant recipient sites using computerized tomography (CT) and to investigate the influence of local bone density on implant stability parameters and implant success.</p> <p>Methods</p> <p>A total of 300 implants were placed in 111 patients between 2003 and 2005. The bone density in each implant recipient site was determined using CT. Insertion torque and resonance frequency analysis were used as implant stability parameters. The peak insertion torque values were recorded with OsseoCare machine. The resonance frequency analysis measurements were performed with Osstell instrument immediately after implant placement, 6, and 12 months later.</p> <p>Results</p> <p>Of 300 implants placed, 20 were lost, meaning a survival rate of %. 93.3 after three years (average 3.7 ± 0.7 years). The mean bone density, insertion torque and RFA recordings of all 300 implants were 620 ± 251 HU, 36.1 ± 8 Ncm, and 65.7 ± 9 ISQ at implant placement respectively; which indicated statistically significant correlations between bone density and insertion torque values (p < 0.001), bone density and ISQ values (p < 0.001), and insertion torque and ISQ values (p < 0.001). The mean bone density, insertion torque and RFA values were 645 ± 240 HU, 37.2 ± 7 Ncm, and 67.1 ± 7 ISQ for 280 successful implants at implant placement, while corresponding values were 267 ± 47 HU, 21.8 ± 4 Ncm, and 46.5 ± 4 ISQ for 20 failed implants; which indicated statistically significant differences for each parameter (p < 0.001).</p> <p>Conclusion</p> <p>CT is a useful tool to determine the bone density in the implant recipient sites, and the local bone density has a prevailing influence on primary implant stability, which is an important determinant for implant success.</p

    Método automático de clasificación de color en dientes humanos usando aprendizaje de máquina

    Get PDF
    Trabajo de InvestigaciónActualmente el proceso de identificación del color de los dientes para la fabricación de prótesis dentales es realizado manualmente por un experto que, utilizando un método de identificación visual, determina el color de las piezas dentales en la boca del paciente, usando guías de color como la VITA®. A pesar de que el método visual es el más utilizado para la identificación del color de dientes, este se ve afectado por distintas variables tales como: el cansancio del experto, la luminosidad en el ambiente, salud visual del especialista, entre otras que influyen en la identificación del color en los dientes. Los errores en la clasificación del color de los dientes pueden generar pérdidas de tiempo lo que implicaría en consecuencia sobrecostos que afectarían directamente al fabricante y la satisfacción final del cliente.1. Planteamiento del problema 2. Pregunta de investigación 3. Objetivos 4. Estado del arte 5. Marco de referencia 6. Alcances y limitaciones 7. Metodología 8. Diseño metodológico 9. Discusión y resultados 10. Conclusiones 11. Trabajos futuros 12. Bibliografía 13. ANEXOSPregradoIngeniero de Sistema

    Treatment with Chymopapain

    No full text
    corecore