    Modelling the Non-equilibrium Electric Double Layer at Oil-pressboard Interface of High Voltage Transformers

    No full text
    In large oil-filled power transformers, cellulose-based pressboard and paper are used throughout for electrical insulation. Microscopic views have shown that pressboard insulation is a fibrous and porous structure with non-homogeneous surface. It has been recognised that the pressboard structure is more porous towards the edge [1]. The pores within the pressboard allow oil absorption during impregnation process and provide paths for oil to penetrate until saturation is reached. The ratio of fibre and oil changes as the material structure changes from a medium of bulk oil-pressboard composite toward the bulk oil medium. The porosity of pressboard can also result in impurities within the oil being drawn into the pressboard. It has also been recognised that physicochemical process of a liquid in contact with solid wall leads to the formation of electric double layer (EDL) in the liquid region [2, 3]. The material properties and geometry of pressboard thus lead to a complex oil-pressboard interface. A 2-D model of oil-pressboard interface has been constructed using Comsol Multiphysics Finite Element Analysis software and this is shown in Figure 1. The mathematical model considers the dissociation of a generic impurity in the oil into positive and negative ions and considers the role of the porous and non-homogeneous wall of pressboard in the formation of the EDL. The pressboard, which is represented by different arrays of fibre, promotes preferential adsorption and desorption processes between ions in the oil and unoccupied fibre surfaces of oil impregnated pressboard. The model studies the non-equilibrium charge density profile in the EDL at the oil-pressboard interface when the oil is in the stationary condition

    The views of young people with congenital cardiac disease on designing the services for their treatment

    Get PDF
    Background and purpose: There is little documented evidence of young people with congenital cardiac disease being consulted as to what help, if any, they really need in relation to their condition. Most research concentrates on the medical aspects of the condition. There are studies of psychological and social functioning, but few have directly sought the opinions of the young people. More recent research has indicated a need for health professionals to develop services to meet both psychosocial and physical needs of young people with congenital cardiac disease. The findings of the recent Kennedy Report support this need. The purpose of this study was to explore the views of young people with a range of congenital cardiac conditions, on what would help them better deal with their condition, and when and how help might be provided. Methods: This was a qualitative study using semi-structured interviews. We interviewed 16 young people in their own home. Interviews were tape-recorded and transcribed. Analysis was conducted using the "Framework" method. Results: Whilst most of the young people interviewed actively manage their condition, they think more support from others would be beneficial. Issues of activity and communication were cited most often as areas requiring more understanding from people they interact with, for example teachers and peers. The discussion focuses on how health professionals might change or develop their practice to help young people better cope with their condition. Conclusions: Most of the young people interviewed in this study had developed their own strategies for coping with their condition. Although this is a small study, the young people provided important suggestions as to how health professionals could better develop current services

    A simple screening method for determining knowledge of the appropriate levels of activity and risk behaviour in young people with congenital cardiac conditions

    Get PDF
    Objective: To assess a novel method for assessing risk and providing advice about activity to children and young people with congenital cardiac disease and their parents. Design and setting: Questionnaire survey in outpatient clinics at a tertiary centre dealing with congenital cardiac disease, and 6 peripheral clinics. Interventions: Children or their parents completed a brief questionnaire. If this indicated a desire for help, or a serious mismatch between advised and real level of activity, they were telephoned by a physiotherapist. Main measures of outcome: Knowledge about appropriate levels of activity, and identification of the number exercising at an unsafe level, the number seeking help, and the type of help required. Results: 253/258 (98.0%) questionnaires were returned, with 119/253 (47.0%) showing incorrect responses in their belief about their advised level of exercise; 17/253 (6.7%) had potentially dangerous overestimation of exercise. Asked if they wanted advice 93/253 (36.8%) said “yes”, 43/253 (17.0%) “maybe”, and 117/253 (46.2%) “no”. Of those contacted by phone to give advice, 72.7% (56/77) required a single contact and 14.3% (11/77) required an intervention that required more intensive contact lasting from 2 up to 12 weeks. Of the cohort, 3.9% (3/77) were taking part in activities that put them at significant risk. Conclusions: There is a significant lack of knowledge about appropriate levels of activity, and a desire for further advice, in children and young people with congenital cardiac disease. A few children may be at very significant risk. These needs can be identified, and clinical risk reduced, using a brief self-completed questionnaire combined with telephone follow-up from a suitably knowledgeable physiotherapist

    The views of parents concerning the planning of services for rehabilitation of families of children with congenital cardiac disease

    Get PDF
    Background and purpose: Although much previous research has focused on the medical aspects of congenital cardiac disease, there is a growing body of research which suggests that families may need help and support with the wider issues associated with the medical condition. We have previously ascertained from young people with congenital cardiac disease their views on this subject. The purpose of this study was to obtain the views of their parents about the need for, and shape of, services for rehabilitation. Methods: This was a qualitative study using semi-structured interviews. We interviewed 17 parents in their own home. Interviews were tape-recorded and transcribed. Results: Parents would welcome more help and support from health professionals to enable them to manage more effectively the condition with their children. Particular areas of concern relate to the information they receive about the condition; communication between themselves and health professionals; establishing safe levels of activity; and managing the condition at school. Conclusions: This is a small study of the experiences and views of parents, which provides some important information on ways in which health professionals. could address the current lack of services for rehabilitation

    Use of Machine Learning for Partial Discharge Discrimination

    No full text
    Partial discharge (PD) measurements are an important tool for assessing the condition of power equipment. Different sources of PD have different effects on the insulation performance of power apparatus. Therefore, discrimination between PD sources is of great interest to both system utilities and equipment manufacturers. This paper investigates the use of a wide bandwidth PD on-line measurement system to facilitate automatic PD source identification. Three artificial PD models were used to simulate typical PD sources which may exist within power systems. Wavelet analysis was applied to pre-process the obtained measurement data. This data was then processed using correlation analysis to cluster the discharges into different groups. A machine learning technique, namely the support vector machine (SVM) was then used to identify between the different PD sources. The SVM is trained to differentiate between the inherent features of each discharge source signal. Laboratory experiments indicate that this approach is applicable for use with field measurement data

    Electromagnetic field application to underground power cable detection

    No full text
    Before commencing excavation or other work where power or other cables may be buried, it is important to determine the location of cables to ensure that they are not damaged. This paper describes a method of power-cable detection and location that uses measurements of the magnetic field produced by the currents in the cable, and presents the results of tests performed to evaluate the method. The cable detection and location program works by comparing the measured magnetic field signal with values predicted using a simple numerical model of the cable. Search coils are used as magnetic field sensors, and a measurement system is setup to measure the magnetic field of an underground power cable at a number of points above the ground so that it can detect the presence of an underground power cable and estimate its position. Experimental investigations were carried out using a model and under real site test conditions. The results show that the measurement system and cable location method give a reasonable prediction for the position of the target cable

    Effect of Cross-Linking on the Electrical Properties of LDPE and its Lightning Impulse Ageing Characteristics

    No full text
    Cross-linked polyethylene (XLPE) is commonly used within high voltage cable insulation. It has improved thermal and mechanical resistance compared to normal low density polyethylene (LDPE). However, the cross-linking process may also vary the electrical characteristics of the material. This paper investigates changes in electrical properties of one type of LDPE before and after cross-linking. The effective lightning resistance is also considered, as the application of repetitive lightning impulse overvoltages can be a factor in insulation material ageing of high voltage cables. The material was cross-linked using trigonox-145 peroxide with controlled concentration. Samples were moulded to have a Rogowski profile and gold coated to make sure that they are evenly electrically stressed. Obtained results show that there are reductions in both space charge injection and the permittivity of the material after it is cross-linked. The breakdown strength of the material was also improved. However, the samples studied are more susceptible to ageing due to lightning impulses

    Investigation of Partial Discharge in Solid Dielectric under DC Voltage

    No full text
    A partial discharge, or PD, is defined as an electrical discharge that is localized within only a part of the insulation between two separated conductors. Recent research on PD mainly focuses on the study of PD characteristics under AC voltage. Compared with DC, PD under AC is more serious and can be easily detected in terms of PD number. As the results of these concentrated research, the understanding of PD under AC condition has been significantly improved and features extracted from PD measurements have been used to diagnose the insulation condition of many power apparatus. Recently, rapid development in HVDC transmission and power grids connection, and widely applied DC cable and gas-insulated switchgear because of their benefit in long distance usage lead to an increasing concern about PD under DC. However, available study for the condition is little and related research is therefore necessary and essential for understanding the lifetime and reliability of apparatus. <br/

    Location of Partial Discharges within a Transformer Winding Using Principal Component Analysis

    No full text
    Partial discharge (PD) may occur in a transformer winding due to ageing processes or defects introduced during manufacture. A partial discharge is defined as a localised electric discharge that only partially bridges the dielectric insulator between conductors when the electric field exceeds a critical value. The presence of PD does not necessarily indicate imminent failure of the transformer but it is a serious degradation and ageing mechanism which can be considered as a precursor of transformer failure. PD might occur anywhere along the transformer winding and the discharge signal can propagate along the winding to the bushing and neutral to earth connections. As far as maintenance and replacement processes are concerned, it is important to identify the location of PD activity so any repair or replace decision is assured to be cost effective. Therefore, identification of a PD source as well as its location along the transformer winding is of great interest to both manufacturers and system operators. The wavelet transform is a mathematical function that can be used to decompose a PD signal into detail levels and an approximation. Wavelet filtering is often used to improve signal to noise ratio (SNR) of measured signals, but in this case it is used to identify the distribution of signal energies in both the time and frequency domains. This method produces a feature vector for each captured discharge signal. The use of principle component analysis (PCA) can compress this data into three dimensions, to aid visualisation. Data captured by sensors over hundreds of cycles of applied voltage can be analysed using this approach. An experiment (Figure 1) has been developed that can be used to create PD data in order to investigate the feasibility of using PCA analysis to identify PD source location
    • …