55 research outputs found

    Helium in the adult critical care setting

    Get PDF
    Helium is a low-density inert gas whose physical properties are very different from those of nitrogen and oxygen. Such properties could be clinically useful in the adult critical care setting, especially in patients with upper to more distal airway obstruction requiring moderate to intermediate levels of FiO2. However, despite decades of utilization and reporting, it is still difficult to give any firm clinical recommendation in this setting. Numerous case reports are available in the context of upper airway obstruction of different origins, but there is a lack of controlled studies for this indication. One study reported a helium-induced beneficial effect on surrogates of work of breathing after extubation in non-COPD patients, possibly in relation to laryngeal consequences of tracheal intubation. Physiological benefits of helium-oxygen breathing have been demonstrated in the context of acute severe asthma, but there is a lack of large controlled studies demonstrating an effect on pertinent clinical endpoints, except for a study reported only as an abstract, which mentioned a reduction in the intubation rate in helium-treated patients. Finally, there are a number of physiological studies in the context of COLD-COPD patients demonstrating a beneficial effect, mainly by a reduction in the resistive inspiratory work of breathing but also by a reduction in hyperinflation. Reduction of hypercapnia was mainly observed in spontaneously breathing and noninvasively ventilated helium-treated patients but not in intubated patients during controlled ventilation, suggesting that the decrease in PaCO2 was mainly in relation to a diminution in CO2 production, related to the diminution in work of breathing and not an improved alveolar ventilation. Moreover, there is little evidence that helium-oxygen could improve parameters of heterogeneity in such patients. Two RCTs were unable to demonstrate a reduction in the intubation rate in such setting, but they were likely underpowered. An adequately powered international multicentric study is ongoing and will help to determinate the exact place of the helium-oxygen mixture in the future. The place of the mixture during the weaning period will deserve further evaluation

    Comparison of the Airtraq® and Truview® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Paramedics are frequently required to perform tracheal intubation, a potentially life-saving manoeuvre in severely ill patients, in the prehospital setting. However, direct laryngoscopy is often more difficult in this environment, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Airtraq<sup>® </sup>and Truview<sup>® </sup>laryngoscopes may reduce this risk.</p> <p>Methods</p> <p>We compared the efficacy of these devices to the Macintosh laryngoscope when used by 21 Paramedics proficient in direct laryngoscopy, in a randomized, controlled, manikin study. Following brief didactic instruction with the Airtraq<sup>® </sup>and Truview<sup>® </sup>laryngoscopes, each participant took turns performing laryngoscopy and intubation with each device, in an easy intubation scenario and following placement of a hard cervical collar, in a SimMan<sup>® </sup>manikin.</p> <p>Results</p> <p>The Airtraq<sup>® </sup>reduced the number of optimization manoeuvres and reduced the potential for dental trauma when compared to the Macintosh, in both the normal and simulated difficult intubation scenarios. In contrast, the Truview<sup>® </sup>increased the duration of intubation attempts, and required a greater number of optimization manoeuvres, compared to both the Macintosh and Airtraq<sup>® </sup>devices.</p> <p>Conclusion</p> <p>The Airtraq<sup>® </sup>laryngoscope performed more favourably than the Macintosh and Truview<sup>® </sup>devices when used by Paramedics in this manikin study. Further studies are required to extend these findings to the clinical setting.</p

    Comparison of the Airtraq® and Truview® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Paramedics are frequently required to perform tracheal intubation, a potentially life-saving manoeuvre in severely ill patients, in the prehospital setting. However, direct laryngoscopy is often more difficult in this environment, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Airtraq<sup>® </sup>and Truview<sup>® </sup>laryngoscopes may reduce this risk.</p> <p>Methods</p> <p>We compared the efficacy of these devices to the Macintosh laryngoscope when used by 21 Paramedics proficient in direct laryngoscopy, in a randomized, controlled, manikin study. Following brief didactic instruction with the Airtraq<sup>® </sup>and Truview<sup>® </sup>laryngoscopes, each participant took turns performing laryngoscopy and intubation with each device, in an easy intubation scenario and following placement of a hard cervical collar, in a SimMan<sup>® </sup>manikin.</p> <p>Results</p> <p>The Airtraq<sup>® </sup>reduced the number of optimization manoeuvres and reduced the potential for dental trauma when compared to the Macintosh, in both the normal and simulated difficult intubation scenarios. In contrast, the Truview<sup>® </sup>increased the duration of intubation attempts, and required a greater number of optimization manoeuvres, compared to both the Macintosh and Airtraq<sup>® </sup>devices.</p> <p>Conclusion</p> <p>The Airtraq<sup>® </sup>laryngoscope performed more favourably than the Macintosh and Truview<sup>® </sup>devices when used by Paramedics in this manikin study. Further studies are required to extend these findings to the clinical setting.</p

    Be careful with triage in emergency departments: interobserver agreement on 1,578 patients in France

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>For several decades, emergency departments (EDs) utilization has increased, inducing ED overcrowding in many countries. This phenomenon is related partly to an excessive number of nonurgent patients. To resolve ED overcrowding and to decrease nonurgent visits, the most common solution has been to triage the ED patients to identify potentially nonurgent patients, i.e. which could have been dealt with by general practitioner. The objective of this study was to measure agreement among ED health professionals on the urgency of an ED visit, and to determine if the level of agreement is consistent among different sub-groups based on following explicit criteria: age, medical status, type of referral to the ED, investigations performed in the ED, and the discharge from the ED.</p> <p>Methods</p> <p>We conducted a multicentric cross-sectional study to compare agreement between nurses and physicians on categorization of ED visits into urgent or nonurgent. Subgroups stratified by criteria characterizing the ED visit were analyzed in relation to the outcome of the visit.</p> <p>Results</p> <p>Of 1,928 ED patients, 350 were excluded because data were lacking. The overall nurse-physician agreement on categorization was moderate (kappa = 0.43). The levels of agreement within all subgroups were variable and low. The highest agreement concerned three subgroups of complaints: cranial injury (kappa = 0.61), gynaecological (kappa = 0.66) and toxicology complaints (kappa = 1.00). The lowest agreement concerned two subgroups: urinary-nephrology (kappa = 0.09) and hospitalization (kappa = 0.20). When categorization of ED visits into urgent or nonurgent cases was compared to hospitalization, ED physicians had higher sensitivity and specificity than nurses (respectively 94.9% versus 89.5%, and 43.1% versus 30.9%).</p> <p>Conclusions</p> <p>The lack of physician-nurse agreement and the inability to predict hospitalization have important implications for patient safety. When urgency screening is used to determine treatment priority, disagreement might not matter because all patients in the ED are seen and treated. But using assessments as the basis for refusal of care to potential nonurgent patients raises legal, ethical, and safety issues. Managed care organizations should be cautious when applying such criteria to restrict access to EDs.</p

    Nonurgent patients in the emergency department? A French formula to prevent misuse

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Overcrowding in emergency department (EDs) is partly due to the use of EDs by nonurgent patients. In France, the authorities responded to the problem by creating primary care units (PCUs): alternative structures located near hospitals. The aims of the study were to assess the willingness of nonurgent patients to be reoriented to a PCU and to collect the reasons that prompted them to accept or refuse.</p> <p>Methods</p> <p>We carried out a cross sectional survey on patients' use of EDs. The study was conducted in a French hospital ED. Patients were interviewed about their use of health services, ED visits, referrals, activities of daily living, and insurance coverage status. Patients' medical data were also collected.</p> <p>Results</p> <p>85 patients considered nonurgent by a triage nurse were asked to respond to a questionnaire. Sex ratio was 1.4; mean age was 36.3 +/- 11.7 years.</p> <p>Most patients went to the ED autonomously (76%); one third (31.8%) had consulted a physician. The main reasons for using the ED were difficulty to get an appointment with a general practitioner (22.3%), feelings of pain (68.5%), and the availability of medical services in the ED, like imaging, laboratory tests, and drug prescriptions (37.6%). Traumatisms and wounds were the main medical reasons for going to the ED (43.5%).</p> <p>More than two-thirds of responders (68%) were willing to be reoriented towards PCUs. In the multivariate analysis, only employment and the level of urgency perceived by the patient were associated with the willingness to accept reorientation. Employed persons were 4.5 times more likely to accept reorientation (OR = 4.5 CI (1.6-12.9)). Inversely, persons who perceived a high level of urgency were the least likely to accept reorientation (OR = 0.9 CI (0.8-0.9).</p> <p>Conclusions</p> <p>Our study provides information on the willingness of ED patients to accept reorientation and shows the limits of its feasibility. Alternative structures such as PCUs near the ED seem to respond appropriately to the growing demands of nonurgent patients. Reorientation, however, will be successful only if the new structures adapt their opening hours to the needs of nonurgent patients and if their physicians can perform specific technical skills.</p

    Aquatic plant decline in Lake Ellesmere : a case for macrophyte management in a shallow New Zealand lake : a case for macrophyte management in a shallow New Zealand lake : a thesis submitted in partial fulfilment of the requirements for the degree of Doctor of Philosophy in the University of Canterbury [Lincoln College]

    No full text
    The biology and ecology of aquatic Ellesmere, a shallow coastal lake submerged plants were studied in Lake in the South Island of New Zealand. The aim of the study was to understand previous declines of macrophytes in the lake as well as their non-regeneration after a major disturbance event. Such an understanding was assumed to play a central role in the overall management of the lake. Declines of aquatic plants were first reviewed world wide to identify potential sources of perturbation or stress for macrophyte communities. In Lake Ellesmere, wave action, grazing, sediment accretion, water level fluctuations, inorganic and organic turbidity, and salinity were identified as having a potential negative effect on plant growth. The effects of salinity and light on the growth of Ruppia megacarpa and Ruppia polycarpa seedlings were investigated in glasshouse experiments. Both factors were shown to affect growth. Poor light reduced rhizome elongation which may prevent the anchoring of seedlings that are continuously exposed to a turbid and turbulent environment. Growth was also found to be reduced under salinities above 10 PPT. Such salinities occur in the field after prolonged lake openings. A study of the underwater lake environment showed that inorganic suspensoids were mainly responsible for the high turbidity of the lake. About 40% of the reduction in light penetration in the water column was due to shading by phytoplankton. Levels of inorganic suspensoids were highly correlated to wind velocity. Relationships between clarity determinants and optical properties were also established. Their potential use for future management is evaluated. Standing crops of the main species were obtained from two areas in the lake in the summers of 1985-1986 and 1986-1987 during a sudden period of macrophyte regeneration. This allowed the potential for aquatic plant reestablishment to be assessed. Recent developments in ecological theory and plant population biology were used in this assessment and proved to be very valuable. Measures that could favour re-establishment are presented and their integration in future especially in regard lake management is discussed. A new strategy, to lake level fluctuations, was found desirable. Experimental management, where any alternative measure is in the nature of an experiment rather than being a programme with predetermined results, is finally suggested as a very appropriate approach to macrophyte management that may reduce uncertainty in the future management of shallow lakes

    Aquatic vegetation of lake Annecy

    No full text
    International audienc

    BIODIVERSITY AND BIOGEOGRAPHY OF FRESHWATER CRUSTACEANS (DECAPODA: NATANTIA) FROM VANUATU, A COMPARISON WITH FIJI AND NEW CALEDONIA.

    No full text
    This is the first comprehensive study of freshwater decapoda crustaceans from Vanuatu. Of the nineteen species collected during this study, eighteen appear to be new records for the archipelago. However none of these species is endemic to Vanuatu, nine having a Pacific distribution and ten an Indo-Pacific distribution. Half of the species recorded were widely distributed in Vanuatu, whereas the others were more restricted. A comparison is made with the freshwater decapoda fauna of the two neighbouring archipelagoes namely, those of Fiji and New Caledonia, which have already been thoroughly surveyed
    corecore