2,133 research outputs found

    Integrating Early-Separation Dipoles in CMS

    Get PDF
    Proposed methods of reducing the geometrical effects of the beam crossing angle include a dipole located close to the interaction point. In this note, I discuss the integration of the early separation dipole in the CMS detector. It appears that the forces and torques on the dipole are very great, and may prevent its use

    Design parameters for the Very Large Hadron Collider

    Get PDF
    The goal of the Very Large Hadron Collider (VLHC) is to extend the energy frontier beyond LHC. The proposed design center-of-mass energy for the VLHC pp collider is 100 TeV, with a luminosity of le34 cm/sup -2/ sec/sup -1/. At present accelerator designs and calculations are being carried out for two different magnet technologies, one using superferric magnets at 2 Tesla (T), the other using high-field design with B>10 T. This paper summarizes the accelerator parameters for these two designs. We discuss the design parameters that have the largest effects on the performance of the accelerator and therefore need careful optimization. (11 refs)

    COBE Observations of the Microwave Counterparts of Gamma Ray Bursts

    Get PDF
    We have used the data from the COBE satellite to search for delayed microwave emission (31 - 90 GHz) from Gamma Ray Bursts (GRBs). The large 7∘7^\circ beam of COBE is well matched to the large positional uncertainties in the GRB locations, although it also means that fluxes from (point source) GRB objects will be diluted. In view of this we are doing a statistical search of the GRBs which occurred during the currently released COBE DMR data (years 1990 and 1991), which overlap ∼200\sim 200 GRBs recorded by GRO. Here we concentrate on just the top 10 GRBs (in peak counts/second). We obtain the limits on the emission by comparing the COBE fluxes before and after the GRB at the GRB location. Since it is thought that the microwave emission should lag the GRB event, we have searched the GRB position for emission in the few months following the GRB occurrence.Comment: 5 pages, LaTE

    Prototype 9.7 m Schwarzschild-Couder telescope for the Cherenkov Telescope Array: status of the optical system

    Full text link
    The Cherenkov Telescope Array (CTA) is an international project for a next-generation ground-based gamma ray observatory, aiming to improve on the sensitivity of current-generation experiments by an order of magnitude and provide energy coverage from 30 GeV to more than 300 TeV. The 9.7m Schwarzschild-Couder (SC) candidate medium-size telescope for CTA exploits a novel aplanatic two-mirror optical design that provides a large field of view of 8 degrees and substantially improves the off-axis performance giving better angular resolution across all of the field of view with respect to single-mirror telescopes. The realization of the SC optical design implies the challenging production of large aspherical mirrors accompanied by a submillimeter-precision custom alignment system. In this contribution we report on the status of the implementation of the optical system on a prototype 9.7 m SC telescope located at the Fred Lawrence Whipple Observatory in southern Arizona.Comment: Proceedings of the 35th International Cosmic Ray Conference (ICRC 2017), Busan, Korea. All CTA contributions at arXiv:1709.0348

    Can hyperbolic phase of Brans-Dicke field account for Dark Matter?

    Full text link
    We show that the introduction of a hyperbolic phase for Brans-Dicke (BD) field results in a flat vacuum cosmological solution of Hubble parameter H and fractional rate of change of BD scalar field, F which asymptotically approach constant values. At late stages, hyperbolic phase of BD field behaves like dark matter

    Leak-Tight Welding Experience from the Industrial Assembly of the LHC Cryostats at CERN

    Get PDF
    The assembly of the approximately 1700 LHC main ring cryostats at CERN involved extensive welding of cryogenic lines and vacuum vessels. More than 6 km of welding requiring leak tightness to a rate better than 1.10-9 mbar.l.s-1 on stainless steel and aluminium piping and envelopes was made, essentially by manual welding but also making use of orbital welding machines. In order to fulfil the safety regulations related to pressure vessels and to comply with the leak-tightness requirements of the vacuum systems of the machine, welds were executed according to high qualification standards and following a severe quality assurance plan. Leak detection by He mass spectrometry was extensively used. Neon leak detection was used successfully to locate leaks in the presence of helium backgrounds. This paper presents the quality assurance strategy adopted for welds and leak detection. It presents the statistics of non-conformities on welds and leaks detected throughout the entire production and the advances in the use of alternative leak detection methods in an industrial environment

    A Titanium Nitride Absorber for Controlling Optical Crosstalk in Horn-Coupled Aluminum LEKID Arrays for Millimeter Wavelengths

    Full text link
    We discuss the design and measured performance of a titanium nitride (TiN) mesh absorber we are developing for controlling optical crosstalk in horn-coupled lumped-element kinetic inductance detector arrays for millimeter-wavelengths. This absorber was added to the fused silica anti-reflection coating attached to previously-characterized, 20-element prototype arrays of LEKIDs fabricated from thin-film aluminum on silicon substrates. To test the TiN crosstalk absorber, we compared the measured response and noise properties of LEKID arrays with and without the TiN mesh. For this test, the LEKIDs were illuminated with an adjustable, incoherent electronic millimeter-wave source. Our measurements show that the optical crosstalk in the LEKID array with the TiN absorber is reduced by 66\% on average, so the approach is effective and a viable candidate for future kilo-pixel arrays.Comment: 7 pages, 5 figures, accepted for publication in the Journal of Low Temperature Physic

    ARCADE 2 Measurement of the Extra-Galactic Sky Temperature at 3-90 GHz

    Full text link
    The ARCADE 2 instrument has measured the absolute temperature of the sky at frequencies 3, 8, 10, 30, and 90 GHz, using an open-aperture cryogenic instrument observing at balloon altitudes with no emissive windows between the beam-forming optics and the sky. An external blackbody calibrator provides an {\it in situ} reference. Systematic errors were greatly reduced by using differential radiometers and cooling all critical components to physical temperatures approximating the CMB temperature. A linear model is used to compare the output of each radiometer to a set of thermometers on the instrument. Small corrections are made for the residual emission from the flight train, balloon, atmosphere, and foreground Galactic emission. The ARCADE 2 data alone show an extragalactic rise of 50±750\pm7 mK at 3.3 GHz in addition to a CMB temperature of 2.730±.0042.730\pm .004 K. Combining the ARCADE 2 data with data from the literature shows a background power law spectrum of T=1.26±0.09T=1.26\pm 0.09 [K] (ν/ν0)−2.60±0.04(\nu/\nu_0)^{-2.60\pm 0.04} from 22 MHz to 10 GHz (ν0=1\nu_0=1 GHz) in addition to a CMB temperature of 2.725±.0012.725\pm .001 K.Comment: 11 pages 5 figures Submitted to Ap
    • …
    corecore