524 research outputs found

    Hemodynamics and Mechanobiology of Aortic Valve Inflammation and Calcification

    Get PDF
    Cardiac valves function in a mechanically complex environment, opening and closing close to a billion times during the average human lifetime, experiencing transvalvular pressures and pulsatile and oscillatory shear stresses, as well as bending and axial stress. Although valves were originally thought to be passive pieces of tissue, recent evidence points to an intimate interplay between the hemodynamic environment and biological response of the valve. Several decades of study have been devoted to understanding these varied mechanical stimuli and how they might induce valve pathology. Here, we review efforts taken in understanding the valvular response to its mechanical milieu and key insights gained from in vitro and ex vivo whole-tissue studies in the mechanobiology of aortic valve remodeling, inflammation, and calcification

    Efficacy of Colletotrichum gloeosporioides, potential fungi for bio control of Echinochloa crus-galli (Barnyard grass)

    Get PDF
    A systematic field study was conducted in agricultural fields such as food crops, pulses, vegetable crops, oil crops and commercial crops to estimate infestation of Echinochloa crus – galli (barnyard grass), a common terrestrial weed belonging to family poaceae. The in vitro pathogenicity studies on barnyard grass were conducted using spore inoculum (8X107/ml) of an indigenous fungus, Colletotrichum gloeosporioides. The pathogen was re-isolated from inoculated plants to fulfill Koch’s postulates and confirmed its host specificity on barnyard grass. The disease by the isolate was critically analyzed and the results revealed that Colletotrichum gloeosporioides is a potential agent to biological control of barnyard grass. The results revealed that the pathogen causes significantly (P < 0.05) severe infection on host weed and destructs the weed population by leaf spot diseases. The findings of the research suggested that the isolate Colletotrichum gloeosporioides is highly virulent and host-specific, and recommended for further studies as a promising biocontrol agent against barnyard grass weed. Keywords: Mycoherbicides, Barnyard grass, Colletotrichum gloeosporioides, Koch’s postulate

    An Ex Vivo Study of the Biological Properties of Porcine Aortic Valves in Response to Circumferential Cyclic Stretch

    Get PDF
    Normal physiological mechanical forces cause constant tissue renewal in aortic valve leaflets (AVL) while altered mechanical forces incite changes in their structural and biological properties. The current study aims at characterizing the remodeling properties of AVL subjected to cyclic circumferential stretch in a sterile ex vivo bioreactor. The leaflets cultured were stretched at a maximum rate of 300%s(−1) corresponding to a 15% strain for 48 h. Collagen, sulfated glycosaminoglycan (sGAG), and elastin contents of the stretched, fresh, and statically incubated leaflets were measured. Cusp morphology and cell phenotype were also examined. AVLs exposed to cyclic stretch showed a significant increase in collagen content (p < 0.05) when compared to fresh and statically incubated AVLs. sGAG content was significantly reduced in the stretched AVLs (p < 0.05) when compared to the fresh leaflets and was comparable between stretched and statically incubated AVLs. There was no statistically significant change in elastin content in all the three groups of AVLs (p > 0.05). Native aortic valve morphology was well preserved in stretched leaflets. Immunohistochemistry and immunoblotting studies showed an increased expression of α-smooth muscle actin (α-SMA) in stretched leaflets while α-SMA expression was reduced in statically incubated AVLs when compared to the fresh leaflets. To conclude, circumferential cyclic stretch altered the extracellular matrix remodeling activity of valvular cells, and consequently the extracellular matrix composition of the AVLs. Most interestingly, the contractile and fibrotic phenotypic expression of valve interstitial cells was enhanced. These results show that circumferential cyclic stretch is a possible mediator for AVL remodeling activity

    Toward Designing the Optimal Total Cavopulmonary Connection: an In Vitro Study

    Get PDF
    Background. Understanding the total cavopulmonary connection (TCPC) hemodynamics may lead to improved surgical procedures which result in a more efficient modified circulation. Reduced energy loss will translate to less work for the single ventricle and although univentricular physiology is complex, this improvement could contribute to improved postoperative outcomes. Therefore to conserve energy, one surgical goal is optimization of the TCPC geometry. In line with this goal, this study investigated whether addition of caval curvature or flaring at the connection conserves energy. Methods. TCPC models were made varying the curvature of the caval inlet or by flaring the anastomosis. Steady flow pressure measurements were made to calculate the power loss attributed to each connection design over a range of pulmonary flow splits (70:30 to 30:70). Particle flow visualization was performed for each design and was qualitatively compared to the power losses. Results. Results indicate that curving the cavae toward one pulmonary artery is advantageous only when the flow rate from that cavae matches the flow to the pulmonary artery. Under other pulmonary flow split conditions, the losses in the curved models are significant. In contrast, fully flaring the anastomosis reduced losses over the range of pulmonary flow splits. Power losses were 56% greater for the curving as compared to flaring. Fully flaring without caval offset reduced losses 45% when compared to previous models without flaring. If flaring on all sides was implemented with caval offset, power losses reduced 68% compared to the same nonflared model. Conclusions. The results indicate that preferentially curving the cavae is only optimal under specific pulmonary flow conditions and may not be efficient in all clinical cases. Flaring of the anastomosis has great potential to conserve energy and should be considered in future TCPC procedures

    Toward Designing the Optimal Total Cavopulmonary Connection: an In Vitro Study

    Get PDF
    Background. Understanding the total cavopulmonary connection (TCPC) hemodynamics may lead to improved surgical procedures which result in a more efficient modified circulation. Reduced energy loss will translate to less work for the single ventricle and although univentricular physiology is complex, this improvement could contribute to improved postoperative outcomes. Therefore to conserve energy, one surgical goal is optimization of the TCPC geometry. In line with this goal, this study investigated whether addition of caval curvature or flaring at the connection conserves energy. Methods. TCPC models were made varying the curvature of the caval inlet or by flaring the anastomosis. Steady flow pressure measurements were made to calculate the power loss attributed to each connection design over a range of pulmonary flow splits (70:30 to 30:70). Particle flow visualization was performed for each design and was qualitatively compared to the power losses. Results. Results indicate that curving the cavae toward one pulmonary artery is advantageous only when the flow rate from that cavae matches the flow to the pulmonary artery. Under other pulmonary flow split conditions, the losses in the curved models are significant. In contrast, fully flaring the anastomosis reduced losses over the range of pulmonary flow splits. Power losses were 56% greater for the curving as compared to flaring. Fully flaring without caval offset reduced losses 45% when compared to previous models without flaring. If flaring on all sides was implemented with caval offset, power losses reduced 68% compared to the same nonflared model. Conclusions. The results indicate that preferentially curving the cavae is only optimal under specific pulmonary flow conditions and may not be efficient in all clinical cases. Flaring of the anastomosis has great potential to conserve energy and should be considered in future TCPC procedures

    The Influence of Acoustic Impedance Mismatch on Post-Stenotic Pulsed-Doppler Ultrasound Measurements in a Coronary Artery Model

    Get PDF
    Acoustic impedance mismatch at the fluid-wall interface was shown to affect the spectra from an intravascular Doppler device in an in vitro model with a diameter typical of human coronary arteries. Measurements were obtained first under Poiseuille flow conditions with impedance mismatches of 0%, 7% and 12%, and then under stenosed conditions for the 0% and 7% mismatch cases. For the zero mismatch case, the Doppler spectra could be readily interpreted in terms of fluid mechanical phenomena. When mismatch was present, the spectra from Poiseuille flow exhibited multiple peaks which could not be directly related to the velocity profile. Also, the spectra from stenosed flow with a mismatch of 7% were similar to those from the zero mismatch case but did not exhibit the specific flow-related features as clearly. These results indicate that the impedance mismatch alters the acoustic environment inside the model and that this causes artifact in the Doppler spectra

    Slice Location Dependence of Aortic Regurgitation Measurements with MR Phase Velocity Mapping

    Get PDF
    Although several methods have been used clinically to assess aortic regurgitation (AR), there is no “gold standard” for regurgitant volume measurement. Magnetic resonance phase velocity mapping (PVM) can be used for noninvasive blood flow measurements. To evaluate the accuracy of PVM in quantifying AR with a single imaging slice in the ascending aorta, in vitro experiments were performed by using a compliant aortic model. Attention was focused on determining the slice location that provided the best results. The most accurate measurements were taken between the aortic valve annulus and the coronary ostia where the measured (Y) and actual (X) flow rate had close agreement (Y = 0.954 × + 0.126, r2 = 0.995, standard deviation of error = 0.139 L/min). Beyond the coronary ostia, coronary flow and aortic compliance negatively affected the accuracy of the measurements. In vivo measurements taken on patients with AR showed the same tendency with the in vitro results. In making decisions regarding patient treatment, diagnostic accuracy is very important. The results from this study suggest that higher accuracy is achieved by placing the slice between the aortic valve and the coronary ostia and that this is the region where attention should be focused for further clinical investigation
    corecore