1,200 research outputs found

    Molar pregnancy and co-existent foetus: A report of two cases

    Get PDF
    Molar pregnancy with a co-existent foetus will lead to preterm labour, severe preeclampsia or bleeding in most of the cases and may need urgent intervention. However, if it does not become complicated with preeclampsia or preterm Labour, the outcome is usually good, with minimal post partum complications and so such pregnancies can be managed with watchful waiting and close observation. The first case was a 29 year-old at 19 weeks of gestation, with hypertension, oedema and severe epigastric pain. Karyotypic assessment of the contents of the uterus revealed a 46-XX foetus with no chromosomal abnormality, as well as the molar placenta also suggesting a complete mole with 46-XX. The second case was a 19 year old woman in labour. A pathological study of the delivered contents of the uterus revealed a complete hydatidiform mole and a normal placenta

    Electro-hydrodynamic Pumped Hydraulic Actuation with Application to Active Vibration Control

    Get PDF
    A new type of actuation device has been conceptualized that meets the needs of both large displacement, force and bandwidth within a package more compact than currently available magnetostrictive and stack-type piezoelectric actuators of similar rating. This concept relies on micro-scale electrohydrodynamic (EHD) pumping of a dielectric liquid within small channels. Configured as an actuator, the EHD pump(s) would be used to move fluid between two reservoirs—each having a compliant membrane that interfaces to the world to provide the means to achieve vibration cancellation or micro actuation. Ordinarily limited to generating flow in macroscale applications, the EHD pump, when operating in a thermal induction mode, is shown to exhibit an exciting scaling law as its size is reduced. As the pump volume to surface area decreases, the energy going toward increasing pressure in the pump has an increasingly larger effect. Since the volume/surface area is proportional to 1/a, where a is the characteristic width or diameter of the channels comprising the pump, the pressure head generated scales similarly. Analytical and numerical studies have shown the EHD-pumped actuator to be capable of delivering equal force and bandwidth to magnetostrictive and stack-type piezo actuators, but with considerably greater displacement and roughly 1/10th of the size. Further, this type of actuator offers the possibility for deployment in active vibration control or micro actuation applications at significantly greater temperatures than for piezoelectric and magnetostrictive devices

    Polyhydroxybutyrate accumulation by a Serratia sp

    Get PDF
    A strain of Serratia sp. showed intracellular electron-transparent inclusion bodies when incubated in the presence of citrate and glycerol 2-phosphate without nitrogen source following pregrowth under carbon-limitation in continuous culture. About 1.3 mmol citrate were consumed per 450 mg\ud biomass, giving a calculated yield of maximally 55% of stored material per g of biomass dry wt. The inclusion bodies were stained with Sudan Black and Nile Red (NR), suggesting a lipid material, which was confirmed as polyhydroxybutyrate (PHB) by analysis of molecular fragments by GC and by FTIR spectroscopy of isolated bio-PHB in comparison with reference material. Multi-parameter flow cytometry in conjunction with NR fluorescence, and electron microscopy, showed that not all cells contained heavy PHB bodies, suggesting the potential for increasing\ud the overall yield. The economic attractiveness is\ud enhanced by the co-production of nanoscale hydroxyapatite\ud (HA), a possible high-value precursor for bone replacement materials

    Prevention of methylprednisolone acetate-induced osteoporosis with calcium administration in rat model

    Get PDF
    Glucocorticoid steroids are widely used as anti-inflammatory and immunosuppressive medications and are well known to induce osteoporosis. In Present study 24 rats were randomly divided into four groups (n=6): Group A (control), Group B (sham)that was treated only by normal saline for 1 month.Group C that was treated by methylprednisolone acetate alone (0.2 mg/kg) for 1 month. Group D that was treated by methylprednisolone acetate (0.2 mg/kg) and oral calcium supplementation (15 mg/kg) for 1 month. Changes in concentration of bone metabolic markers such as osteocalcine, acid phosphatase and calcium were evaluated before and after treatment. Bone mineral density (BMD) of lumbar vertebrae was also measured by dual energy X ray absorptiometry (DEXA). The results showed that concentration mean of serum acid phosphatase was increased significantly (P � 0.05) in C and D groups in compared to A and B groups. The concentration mean of serum osteocalcine in group C was decreased significantly (P � 0.05) in comparison to A and B groups but increased significantly in the group D in comparison to group C. The concentration mean of serum calcium was decreased significantly (P � 0.05) in C and D groups in compared to A and B groups. The bone mineral density (g/cm2) was decreased significantly (P � 0.05) in group C in compared to A and B groups. This increased significantly in group D in compared to group C. These results are compatible with the view that low doses of methylprednisolone acetate decreases bone formation and increase bone resorption in the lumbar vertebrae of rats. Calcium administration decreased effects of methylprednisolone. © 2009 Tehran University of Medical Sciences. All rights reserved

    The Interplay Between θ\theta and T

    Full text link
    We extend a recent computation of the dependence of the free energy, F, on the noncommutative scale θ\theta to theories with very different UV sensitivity. The temperature dependence of FF strongly suggests that a reduced number of degrees of freedom contributes to the free energy in the non-planar sector, FnpF_{\rm np}, at high temperature. This phenomenon seems generic, independent of the UV sensitivity, and can be traced to modes whose thermal wavelengths become smaller than the noncommutativity scale. The temperature dependence of FnpF_{\rm np} can then be calculated at high temperature using classical statistical mechanics, without encountering a UV catastrophe even in large number of dimensions. This result is a telltale sign of the low number of degrees of freedom contributing to FF in the non-planar sector at high temperature. Such behavior is in marked contrast to what would happen in a field theory with a random set of higher derivative interactions.Comment: 14 pages, 1 eps figur

    Melatonin pretreated blastocysts along with calcitonin administration improved implantation by upregulation of heparin binding-epidermal growth factor expression in murine endometrium

    Get PDF
    Objective: Implantation failure is an obstacle in assisted reproduction techniques (ART). Calcitonin is a molecules involved in uterine receptivity and embryo implantation. Melatonin can promote embryo quality and improve implantation. This study examines the effect of pretreatment of blastocysts with melatonin and calcitonin on heparin binding-epidermal growth factor (HB-EGF) expression in murine endometrium. Materials and Methods: In this experimental study, we collected 2-cell embryos from the oviducts of 1.5 day pregnant NMRI mice. Embryos were cultured to the blastocyst in GTM medium with or without 10-9 M melatonin. Pregnant and pseudo-pregnant mice received intraperitoneal (IP) injections of 2 IU calcitonin. After 24 hours, we transferred the cultured blastocysts into the uteri of pseudo-pregnant mice. Two days later, implantation sites were counted and we assessed the levels of HB-EGF mRNA and protein in the uteri of naturally pregnant and pseudo-pregnant mice by quantitative real-time polymerase chain reaction (qRT-PCR) and Western blot. Statistical analysis was performed with one-way ANOVA followed by the Tukey post hoc test. P<0.05 was considered statistically significant. Results: Melatonin pretreatment of blastocysts along with calcitonin administration significantly increased HB-EGF mRNA and protein (P<0.001) in the endometrium of pseudo-pregnant mice. Administration of calcitonin in naturally pregnant mice significantly increased HB-EGF mRNA and protein levels (P<0.001). Compared with the control group (2.6 ± 0.5), the average number of implantation sites in the melatonin group (4.6 ± 0.5, P<0.05) and calcitonin group (7 ± 1, P<0.001) significantly increased. There was a significant increase in implantation sites in the combined melatonin and calcitonin group (8.6 ± 0.5, P<0.001). Calcitonin significantly enhanced calcitonin receptor mRNA (P<0.001) and protein (P<0.05) in the uteri of naturally pregnant and pseudo-pregnant mice. Conclusion: Melatonin pretreated blastocysts along with calcitonin increased HB-EGF expression in the uteri of pseudopregnant mice. Calcitonin administration upregulated HB-EGF in uteri of naturally pregnant mice

    Towards reduction of type II theories on SU(3) structure manifolds

    Get PDF
    We revisit the reduction of type II supergravity on SU(3) structure manifolds, conjectured to lead to gauged N=2 supergravity in 4 dimensions. The reduction proceeds by expanding the invariant 2- and 3-forms of the SU(3) structure as well as the gauge potentials of the type II theory in the same set of forms, the analogues of harmonic forms in the case of Calabi-Yau reductions. By focussing on the metric sector, we arrive at a list of constraints these expansion forms should satisfy to yield a base point independent reduction. Identifying these constraints is a first step towards a first-principles reduction of type II on SU(3) structure manifolds.Comment: 20 pages; v2: condition (2.13old) on expansion forms weakened, replaced by (2.13new), (2.14new

    A second look at N=1 supersymmetric AdS_4 vacua of type IIA supergravity

    Full text link
    We show that a class of type IIA vacua recently found within the N=4 effective approach corresponds to compactification on Ads_4 \times S^3 \times S^3/Z_2^3. The results obtained using the effective method completely match the general ten-dimensional analysis for the existence of N=1 warped compactifications on Ads_4 \times M_6. In particular, we verify that the internal metric is nearly-Kahler and that for specific values of the parameters the Bianchi identity of the RR 2-form is fulfilled without sources. For another range of parameters, including the massless case, the Bianchi identity is satisfied when D6-branes are introduced. Solving the tadpole cancellation conditions in D=4 we are able to find examples of appropriate sets of branes. In the second part of this paper we describe how an example with internal space CP^3 but with non nearly-Kahler metric fits into the general analysis of flux vacua.Comment: Latex file, 35 pages, no figures. Reference added, minor corrections adde

    Computational Fluid Dynamics Simulations at Micro-Scale Stenosis for Microfluidic Thrombosis Model Characterization

    Get PDF
    Platelet aggregation plays a central role in pathological thrombosis, preventing healthy physiological blood flow within the circulatory system. For decades, it was believed that platelet aggregation was primarily driven by soluble agonists such as thrombin, adenosine diphosphate and thromboxane A2. However, recent experimental findings have unveiled an intriguing but complementary biomechanical mechanism—the shear rate gradients generated from flow disturbance occurring at sites of blood vessel narrowing, otherwise known as stenosis, may rapidly trigger platelet recruitment and subsequent aggregation. In our Nature Materials 2019 paper [1], we employed microfluidic devices which incorporated micro-scale stenoses to elucidate the molecular insights underlying the prothrombotic effect of blood flow disturbance. Nevertheless, the rheological mechanisms associated with this stenotic microfluidic device are poorly characterized. To this end, we developed a computational fluid dynamics (CFD) simulation approach to systematically analyze the hemodynamic influence of bulk flow mechanics and flow medium. Grid sensitivity studies were performed to ensure accurate and reliable results. Interestingly, the peak shear rate was significantly reduced with the device thickness, suggesting that fabrication of microfluidic devices should retain thicknesses greater than 50 µm to avoid unexpected hemodynamic aberration, despite thicker devices raising the cost of materials and processing time of photolithography. Overall, as many groups in the field have designed microfluidic devices to recapitulate the effect of shear rate gradients and investigate platelet aggregation, our numerical simulation study serves as a guideline for rigorous design and fabrication of microfluidic thrombosis models
    • …
    corecore