19 research outputs found

    Head motion predictability explains activity-dependent suppression of vestibular balance control

    Get PDF
    Vestibular balance control is dynamically weighted during locomotion. This might result from a selective suppression of vestibular inputs in favor of a feed-forward balance regulation based on locomotor efference copies. The feasibility of such a feed-forward mechanism should however critically depend on the predictability of head movements (HMP) during locomotion. To test this, we studied in 10 healthy subjects the differential impact of a stochastic vestibular stimulation (SVS) on body sway (center-of-pressure, COP) during standing and walking at different speeds and compared it to activity-dependent changes in HMP. SVS-COP coupling was determined by correlation analysis in frequency and time domains. HMP was quantified as the proportion of head motion variance that can be explained by the average head trajectory across the locomotor cycle. SVS-COP coupling decreased from standing to walking and further dropped with faster locomotion. Correspondingly, HMP increased with faster locomotion. Furthermore, SVS-COP coupling depended on the gait-cycle-phase with peaks corresponding to periods of least HMP. These findings support the assumption that during stereotyped human self-motion, locomotor efference copies selectively replace vestibular cues, similar to what was previously observed in animal models

    Physical and Tribological Characteristics of Ion-Implanted Diamond Films

    Get PDF
    Unidirectional sliding friction experiments were conducted with a natural, polished diamond pin in contact with both as-deposited and carbon-ion-implanted diamond films in ultrahigh vacuum. Diamond films were deposited on silicon, silicon carbide, and silicon nitride by microwave-plasma-assisted chemical vapor deposition. The as-deposited diamond films were impacted with carbon ions at an accelerating energy of 60 keV and a current density of 50 micron A/cm(exp 2) for approximately 6 min, resulting in a dose of 1.2 x 10(exp 17) carbon ions/cm(exp 2). The results indicate that the carbon ion implantation produced a thin surface layer of amorphous, nondiamond carbon. The nondiamond carbon greatly decreased both friction and wear of the diamond films. The coefficients of friction for the carbon-ion-implanted, fine-grain diamond films were less than 0.1, factors of 20 to 30 lower than those for the as-deposited, fine-grain diamond films. The coefficients of friction for the carbon-ion-implanted, coarse-grain diamond films were approximately 0.35, a factor of five lower than those for the as-deposited, coarse-grain diamond films. The wear rates for the carbon-ion-implanted, diamond films were on the order of 10(exp -6) mm(exp 3)/Nm, factors of 30 to 80 lower than that for the as-deposited diamond films, regardless of grain size. The friction of the carbon-ion-implanted diamond films was greatly reduced because the amorphous, nondiamond carbon, which had a low shear strength, was restricted to the surface layers (less than 0.1 micron thick) and because the underlying diamond materials retained their high hardness. In conclusion, the carbon-ion-implanted, fine-grain diamond films can be used effectively as wear resistant, self-lubricating coatings for ceramics, such as silicon nitride and silicon carbide, in ultrahigh vacuum

    Development and preliminary evaluation of the VPS ReplaySuite: a virtual double-headed microscope for pathology

    Get PDF
    BACKGROUND: Advances in computing and telecommunications have resulted in the availability of a range of online tools for use in pathology training and quality assurance. The majority focus on either enabling pathologists to examine and diagnose cases, or providing image archives that serve as reference material. Limited emphasis has been placed on analysing the diagnostic process used by pathologists to reach a diagnosis and using this as a resource for improving diagnostic performance. METHODS: The ReplaySuite is an online pathology software tool that presents archived virtual slide examinations to pathologists in an accessible video-like format, similar to observing examinations with a double-headed microscope. Delivered through a customised web browser, it utilises PHP (Hypertext PreProcessor) to interact with a remote database and retrieve data describing virtual slide examinations, performed using the Virtual Pathology Slide (VPS). To demonstrate the technology and conduct a preliminary evaluation of pathologists opinions on its potential application in pathology training and quality assurance, 70 pathologists were invited to use the application to review their own and other pathologists examinations of 10 needle-core breast biopsies and complete an electronic survey. 9 pathologists participated, and all subsequently completed an exit survey. RESULTS: Of those who replayed an examination by another pathologist, 83.3% (5/6) agreed that replays provided an insight into the examining pathologists diagnosis and 33.3% (2/6) reconsidered their own diagnosis for at least one case. Of those who reconsidered their original diagnosis, all re-classified either concordant with group consensus or original glass slide diagnosis. 77.7% (7/9) of all participants, and all 3 participants who replayed more than 10 examinations stated the ReplaySuite to be of some or great benefit in pathology training and quality assurance. CONCLUSION: Participants conclude the ReplaySuite to be of some or of great potential benefit to pathology training and quality assurance and consider the ReplaySuite to be beneficial in evaluating the diagnostic trace of an examination. The ReplaySuite removes temporal and spatial issues that surround the use of double-headed microscopes by allowing examinations to be reviewed at different times and in different locations to the original examination. While the evaluation set was limited and potentially subject to bias, the response of participants was favourable. Further work is planned to determine whether use of the ReplaySuite can result in improved diagnostic ability

    Analysis of arterial intimal hyperplasia: review and hypothesis

    Get PDF
    which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Background: Despite a prodigious investment of funds, we cannot treat or prevent arteriosclerosis and restenosis, particularly its major pathology, arterial intimal hyperplasia. A cornerstone question lies behind all approaches to the disease: what causes the pathology? Hypothesis: I argue that the question itself is misplaced because it implies that intimal hyperplasia is a novel pathological phenomenon caused by new mechanisms. A simple inquiry into arterial morphology shows the opposite is true. The normal multi-layer cellular organization of the tunica intima is identical to that of diseased hyperplasia; it is the standard arterial system design in all placentals at least as large as rabbits, including humans. Formed initially as one-layer endothelium lining, this phenotype can either be maintained or differentiate into a normal multi-layer cellular lining, so striking in its resemblance to diseased hyperplasia that we have to name it "benign intimal hyperplasia". However, normal or "benign " intimal hyperplasia, although microscopically identical to pathology, is a controllable phenotype that rarely compromises blood supply. It is remarkable that each human heart has coronary arteries in which a single-layer endothelium differentiates earl

    High current nonlinear transmission line based electron beam driver

    No full text
    A gigawatt-class nonlinear transmission line based electron beam driver is experimentally demonstrated. Four experimental series, each with a different Marx bank charge voltage (15, 20, 25, and 30 kV), were completed. Within each experimental series, shots at peak frequencies ranging from 950 MHz to 1.45 GHz were performed. Peak amplitude modulations of the NLTL output voltage signal were found to range between 18% and 35% for the lowest frequency shots and between 5% and 20% for the highest frequency shots (higher modulation at higher Marx charge voltage). Peak amplitude modulations of the electron beam current were found to range between 10% and 20% for the lowest frequency shots and between 2% and 7% for the highest frequency shots (higher modulation at higher Marx charge voltage)
    corecore