174 research outputs found

    All we need is a cue to remember: The effect of an extinction cue on renewal

    Get PDF
    In the present study, it was investigated by employing a human fear conditioning paradigm whether an extinction retrieval cue can attenuate renewal of conditioned responding after an extinction treatment procedure, and if so, what the precise role of such an extinction cue comprises. It was hypothesized that such a cue can attenuate renewal and would function as a safety signal capable of directly inhibiting the expectancy of an aversive outcome and conditioned skin conductance responding to a conditioned stimulus. The results demonstrated that the extinguished expectancy of an aversive outcome was renewed when the CS was presented outside the extinction context and that an extinction cue attenuated this effect. This extinction cue, however, only transferred its inhibitory properties to other, non-extinguished stimuli when there was no contextual switch. This safety signal function was not observed after a switch in context. Possible functions of the extinction cue and its application in extinction-based exposure treatments are discussed

    Virtual reality eye movements are not inferior to computerized eye movements and exposure in ameliorating aversive memories

    Get PDF
    Background and objectives: Lab studies show that the emotionality and vividness of aversive memories decrease as a result of engaging in a working memory task during the recall of that memory. Translation of the dual tasking working mechanism to a VR program would allow for future VR-EMDR clinical and dissemination trials. The current study took the first step towards that goal by assessing the non-inferiority of a Virtual Reality (VR) eye movement task compared to computerized eye movements in amelioration of aversive autobiographical memory in a student sample. Methods: In a cross-over design, university students (N = 195) recalled three aversive autobiographical memories and received VR Eye Movements (VR EM), Computerized Eye Movements (EM), and Exposure Only (EO). Emotionality and vividness of the memories were assessed before and after each condition. Results: We found VR EM to be non-inferior to Computerized EM and EO in reducing emotionality and vividness. Both EM conditions outperformed the EO condition. Against our expectations, we found steeper declines of emotionality scores in the VR EM condition compared to the Computerized EM. Lastly, we found a sensitization effect in our EO condition: emotionality and vividness increased due to this procedure. Limitations: Despite our efforts in standardizing working memory taxation between the dual tasking conditions (such as viewing angle and speed of eye movements), characteristics of the VR eye movements task might have unintentionally loaded additional working memory. Conclusions: These findings show that VR eye movements could be a viable dual task and might serve as the first step to research VR eye movements in clinical practice

    Limited clinical value of two consecutive post-transplant renal scintigraphy procedures

    Get PDF
    Objectives: Duration of delayed graft function (DGF) and length of hospital stay (LOS) are outcomes of interest in an era that warrants increased efficacy of transplant care whereas renal allografts originate increasingly from marginal donors. While earlier studies investigate the predictive capability of a single renal scintigraphy, this study focuses on the value for both DGF duration and LOS of consecutively performed scintigraphies. Methods: From 2011 to 2014, renal transplant recipients referred for a Tc-99m MAG3 renal scintigraphy were included in a single-center retrospective study. Primary endpoints were DGF duration and LOS. Both the first (≤ 3 days) and second scintigraphies (3–7 days after transplantation) were analyzed using a 4-grade qualitative scale and quantitative indices (TFS, cTER, MUC10, average upslope). Results: We evaluated 200 first and 108 (54%) consecutively performed scintigraphies. The Kaplan-Meier curves for DGF duration and qualitative grading of the first and second scintigraphy showed significant differences between the grades (p < 0.01). The Kaplan-Meier curve for the delta grades between these procedures (lower, equal, or higher grade) did not show significant differences (p = 0.18). Multivariate analysis showed a significant association between the qualitative grades, from the first and second scintigraphy, and DGF duration, HR 1.8 (1.4–2.2, p < 0.01) and 2.8 (1.8–4.3, p < 0.01), respectively. Conclusions: Qualitative grades of single renal scintigraphies, performed within 7 days after transplantation, can be used to make a reliable image-guided decision on the need for dialysis and to predict LOS. A consecutive renal scintigraphy, however, did not show an additional value in the assessment of DGF. Key Points: • Post-transplant renal scintigraphy procedures provide information to predict delayed graft function duration and length of hospital stay. • Performing two consecutive renal scintigraphy procedures within 1 week after transplantation does not strengthen the prediction of delayed graft function duration and length of hospital stay. • Single renal scintigraphy procedures can be used to provide clinicians and patients with a reliable indication of the need for dialysis after transplantation and the expected duration of hospitalization

    <sup>89</sup>Zr-Trastuzumab PET/CT Imaging of HER2-Positive Breast Cancer for Predicting Pathological Complete Response after Neoadjuvant Systemic Therapy:A Feasibility Study

    Get PDF
    Background: Approximately 20% of invasive ductal breast malignancies are human epidermal growth factor receptor 2 (HER2)-positive. These patients receive neoadjuvant systemic therapy (NAT) including HER2-targeting therapies. Up to 65% of patients achieve a pathological complete response (pCR). These patients might not have needed surgery. However, accurate preoperative identification of a pCR remains challenging. A radiologic complete response (rCR) on MRI corresponds to a pCR in only 73% of patients. The current feasibility study investigates if HER2-targeted PET/CT-imaging using Zirconium-89 (89Zr)-radiolabeled trastuzumab can be used for more accurate NAT response evaluation. Methods: HER2-positive breast cancer patients scheduled to undergo NAT and subsequent surgery received a 89Zr-trastuzumab PET/CT both before (PET/CT-1) and after (PET/CT-2) NAT. Qualitative and quantitative response evaluation was performed. Results: Six patients were enrolled. All primary tumors could be identified on PET/CT-1. Four patients had a pCR and two a pathological partial response (pPR) in the primary tumor. Qualitative assessment of PET/CT resulted in an accuracy of 66.7%, compared to 83.3% of the standard-of-care MRI. Quantitative assessment showed a difference between the SUVR on PET/CT-1 and PET/CT-2 (ΔSUVR) in patients with a pPR and pCR of −48% and −90% (p = 0.133), respectively. The difference in tumor-to-blood ratio on PET/CT-1 and PET/CT-2 (ΔTBR) in patients with pPR and pCR was −79% and −94% (p = 0.133), respectively. Three patients had metastatic lymph nodes at diagnosis that were all identified on PET/CT-1. All three patients achieved a nodal pCR. Qualitative assessment of the lymph nodes with PET/CT resulted in an accuracy of 66.7%, compared to 50% of the MRI. Conclusions: NAT response evaluation using 89Zr-trastuzumab PET/CT is feasible. In the current study, qualitative assessment of the PET/CT images is not superior to standard-of-care MRI. Our results suggest that quantitative assessment of 89Zr-trastuzumab PET/CT has potential for a more accurate response evaluation of the primary tumor after NAT in HER2-positive breast cancer.</p

    Baseline and early digital [<sup>18</sup>F]FDG PET/CT and multiparametric MRI contain promising features to predict response to neoadjuvant therapy in locally advanced rectal cancer patients:a pilot study

    Get PDF
    Objective In this pilot study, we investigated the feasibility of response prediction using digital [18F]FDG PET/computed tomography (CT) and multiparametric MRI before, during, and after neoadjuvant chemoradiation therapy in locally advanced rectal cancer (LARC) patients and aimed to select the most promising imaging modalities and timepoints for further investigation in a larger trial. Methods Rectal cancer patients scheduled to undergo neoadjuvant chemoradiation therapy were prospectively included in this trial, and underwent multiparametric MRI and [18F]FDG PET/CT before, 2 weeks into, and 6-8 weeks after chemoradiation therapy. Two groups were created based on pathological tumor regression grade, that is, good responders (TRG1-2) and poor responders (TRG3-5). Using binary logistic regression analysis with a cutoff value of P ≤ 0.2, promising predictive features for response were selected. Results Nineteen patients were included. Of these, 5 were good responders, and 14 were poor responders. Patient characteristics of these groups were similar at baseline. Fifty-seven features were extracted, of which 13 were found to be promising predictors of response. Baseline [T2: volume, diffusion-weighted imaging (DWI): apparent diffusion coefficient (ADC) mean, DWI: difference entropy], early response (T2: volume change, DWI: ADC mean change) and end-of-treatment presurgical evaluation MRI (T2: gray level nonuniformity, DWI: inverse difference normalized, DWI: gray level nonuniformity normalized), as well as baseline (metabolic tumor volume, total lesion glycolysis) and early response PET/CT (Δ maximum standardized uptake value, Δ peak standardized uptake value corrected for lean body mass), were promising features. Conclusion Both multiparametric MRI and [18F]FDG PET/CT contain promising imaging features to predict response to neoadjuvant chemoradiotherapy in LARC patients. A future larger trial should investigate baseline, early response, and end-of-treatment presurgical evaluation MRI and baseline and early response PET/CT.</p

    <sup>89</sup>Zr-Trastuzumab PET/CT Imaging of HER2-Positive Breast Cancer for Predicting Pathological Complete Response after Neoadjuvant Systemic Therapy:A Feasibility Study

    Get PDF
    Background: Approximately 20% of invasive ductal breast malignancies are human epidermal growth factor receptor 2 (HER2)-positive. These patients receive neoadjuvant systemic therapy (NAT) including HER2-targeting therapies. Up to 65% of patients achieve a pathological complete response (pCR). These patients might not have needed surgery. However, accurate preoperative identification of a pCR remains challenging. A radiologic complete response (rCR) on MRI corresponds to a pCR in only 73% of patients. The current feasibility study investigates if HER2-targeted PET/CT-imaging using Zirconium-89 (89Zr)-radiolabeled trastuzumab can be used for more accurate NAT response evaluation. Methods: HER2-positive breast cancer patients scheduled to undergo NAT and subsequent surgery received a 89Zr-trastuzumab PET/CT both before (PET/CT-1) and after (PET/CT-2) NAT. Qualitative and quantitative response evaluation was performed. Results: Six patients were enrolled. All primary tumors could be identified on PET/CT-1. Four patients had a pCR and two a pathological partial response (pPR) in the primary tumor. Qualitative assessment of PET/CT resulted in an accuracy of 66.7%, compared to 83.3% of the standard-of-care MRI. Quantitative assessment showed a difference between the SUVR on PET/CT-1 and PET/CT-2 (ΔSUVR) in patients with a pPR and pCR of −48% and −90% (p = 0.133), respectively. The difference in tumor-to-blood ratio on PET/CT-1 and PET/CT-2 (ΔTBR) in patients with pPR and pCR was −79% and −94% (p = 0.133), respectively. Three patients had metastatic lymph nodes at diagnosis that were all identified on PET/CT-1. All three patients achieved a nodal pCR. Qualitative assessment of the lymph nodes with PET/CT resulted in an accuracy of 66.7%, compared to 50% of the MRI. Conclusions: NAT response evaluation using 89Zr-trastuzumab PET/CT is feasible. In the current study, qualitative assessment of the PET/CT images is not superior to standard-of-care MRI. Our results suggest that quantitative assessment of 89Zr-trastuzumab PET/CT has potential for a more accurate response evaluation of the primary tumor after NAT in HER2-positive breast cancer.</p

    The consequences of a new software package for the quantification of gated-SPECT myocardial perfusion studies

    Get PDF
    Semiquantitative analysis of myocardial perfusion scintigraphy (MPS) has reduced inter- and intraobserver variability, and enables researchers to compare parameters in the same patient over time, or between groups of patients. There are several software packages available that are designed to process MPS data and quantify parameters. In this study the performances of two systems, quantitative gated SPECT (QGS) and 4D-MSPECT, in the processing of clinical patient data and phantom data were compared. The clinical MPS data of 148 consecutive patients were analysed using QGS and 4D-MSPECT to determine the end-diastolic volume, end-systolic volume and left ventricular ejection fraction. Patients were divided into groups based on gender, body mass index, heart size, stressor type and defect type. The AGATE dynamic heart phantom was used to provide reference values for the left ventricular ejection fraction. Although the correlations were excellent (correlation coefficients 0.886 to 0.980) for all parameters, significant differences (p < 0.001) were found between the systems. Bland-Altman plots indicated that 4D-MSPECT provided overall higher values of all parameters than QGS. These differences between the systems were not significant in patients with a small heart (end-diastolic volume < 70 ml). Other clinical factors had no direct influence on the relationship. Additionally, the phantom data indicated good linear responses of both systems. The discrepancies between these software packages were clinically relevant, and influenced by heart size. The possibility of such discrepancies should be taken into account when a new quantitative software system is introduced, or when multiple software systems are used in the same institution.Vascular Biology and Interventio
    • …
    corecore