14 research outputs found

    Distribution of sulfur in power supply lignite from North Hungary

    Get PDF
    Abstract The present article discusses the results of measurements carried out to assess the distribution of different sulfur types in lignite samples deriving from two opencast lignite mines near the villages of Bükkábrány and Visonta. These mines ensure the continuous supply of fuel for one of Hungary's largest thermal power plant. According to our findings no significant differences could be identified between the samples of the two mines based on their total sulfur (St) content. Both lignite types were classified as coals with medium-sulfur content according to the system of Chou (1990). A majority of total sulfur is accumulated in lignite, while in the intercalated carbonaceous shale total sulfur is present in minor amounts. Usually the sequence of the distribution of sulfur among the different bond forms in lignite collected from opencast mine of Visonta is as follows: pyritic sulfur (Sp) > organic sulfur (Sorg) > sulfate sulfur (SSOorg4). In the samples collected from Visonta and Bükkábrány quantities of total sulfur were similar. However, some difference in their distribution among various sulfur types were noted. Although half of the samples were weathered and the amount of pyrite sulfur must have been higher in the weathered lignite of Bükkábrány preceding the oxidation process, the sequence of the distribution of sulfur was likely as follows Sorg ≥ Sp ≥ SSO4

    Validation of diagnostic accuracy using digital slides in routine histopathology

    Get PDF
    Background: Robust hardware and software tools have been developed in digital microscopy during the past years for pathologists. Reports have been advocated the reliability of digital slides in routine diagnostics. We have designed a retrospective, comparative study to evaluate the scanning properties and digital slide based diagnostic accuracy. Methods: 8 pathologists reevaluated 306 randomly selected cases from our archives. The slides were scanned with a 20 × Plan-Apochromat objective, using a 3-chip Hitachi camera, resulting 0.465 μm/pixel resolution. Slide management was supported with dedicated Data Base and Viewer software tools. Pathologists used their office PCs for evaluation and reached the digital slides via intranet connection. The diagnostic coherency and uncertainty related to digital slides and scanning quality were analyzed. Results: Good to excellent image quality of slides was recorded in 96%. In half of the critical 61 digital slides, poor image quality was related to section folds or floatings. In 88.2 % of the studied cases the digital diagnoses were in full agreement with the consensus. Out of the overall 36 incoherent cases, 7 (2.3%) were graded relevant without any recorded uncertainty by the pathologist. Excluding the non-field specific cases from each pathologist’s record this ratio was 1.76 % of all cases. Conclusions: Our results revealed that: 1) digital slide based histopathological diagnoses can be highly coherent with those using optical microscopy; 2) the competency of pathologists is a factor more important than the quality of digital slide; 3) poor digital slide quality do not endanger patient safety as these errors are recognizable by the pathologist and further actions for correction could be taken. Virtual slides: The virtual slide(s) for this article can be found here
    corecore