82 research outputs found

    iNeuroradiology: Websites for Neuroradiologists

    Get PDF

    Imaios.com: "e-MRI” Reloaded and More

    Get PDF

    Retirement of Prof. Dr. Gerhard Schroth

    Get PDF

    Fatal scuba diving incident with massive gas embolism in cerebral and spinal arteries

    Get PDF
    CT and MRI have the potential to become useful adjuncts to forensic autopsy in the near future. The examination of fatal injuries facilitates a profound experience in the clinical-radiological examination of these cases; the more severe findings in corpses with autopsy verification can help one to understand the tiny signs seen in clinical cases of surviving victims. We present the case of a 44-year-old male diver who died from severe decompression sickness after rapid ascent from approximately 120m. Post-mortem CT and MRI studies of the brain and spinal cord revealed extensive gas inclusions in cerebral arteries, spinal arteries and cerebrospinal fluid (CSF) spaces, while the intracranial venous sinuses remained unaffected. These findings were confirmed at autopsy. Appropriate imaging techniques can help forensic pathologists to aim their autopsies at findings that might otherwise remain undetecte

    Locally induced hypothermia for treatment of acute ischaemic stroke: a physical feasibility study

    Get PDF
    During the treatment of stroke by local intra-arterial thrombolysis (LIT) it is frequently possible to pass the blood clot with a micro-catheter, allowing perfusion of brain tissue distally to the occlusion. This possibility allows for new early treatments of ischaemic brain tissue, even before the blood clot has been removed. One potential new approach to preserve brain tissue at risk may be locally induced endovascular hypothermia. Physical parameters such as the required micro-catheter input pressure, output velocity and flow rates, and a heat exchange model, applicable in the case of a micro-catheter placed within a guiding catheter, are presented. Also, a simple cerebral temperature model is derived that models the temperature response of the brain to the perfusion with coolant fluids. Based on this model, an expression has been derived for the time needed to reach a certain cerebral target temperature. Experimental in vitro measurements are presented that confirm the usability of standard commercially available micro-catheters to induce local hypothermia of the brain. If applied in vivo, the model predicts a local cooling rate of ischaemic brain tissue of 300g of approximately 1°C in 1min, which is up to a factor 30-times faster than the time-consuming systemic hypothermia via the skin. Systemic body temperature is only minimally affected by application of local hypothermia, thus avoiding many limitations and complications known in systemic hypothermi

    Dose Reduction in Standard Head CT: First Results from a New Scanner Using Iterative Reconstruction and a New Detector Type in Comparison with Two Previous Generations of Multi-slice CT

    Get PDF
    Purpose: Computed tomography (CT) accounts for more than half of the total radiation exposure from medical procedures, which makes dose reduction in CT an effective means of reducing radiation exposure. We analysed the dose reduction that can be achieved with a new CT scanner [Somatom Edge (E)] that incorporates new developments in hardware (detector) and software (iterative reconstruction). Methods: We compared weighted volume CT dose index (CTDIvol) and dose length product (DLP) values of 25 consecutive patients studied with non-enhanced standard brain CT with the new scanner and with two previous models each, a 64-slice 64-row multi-detector CT (MDCT) scanner with 64 rows (S64) and a 16-slice 16-row MDCT scanner with 16 rows (S16). We analysed signal-to-noise and contrast-to-noise ratios in images from the three scanners and performed a quality rating by three neuroradiologists to analyse whether dose reduction techniques still yield sufficient diagnostic quality. Results: CTDIVol of scanner E was 41.5 and 36.4 % less than the values of scanners S16 and S64, respectively; the DLP values were 40 and 38.3 % less. All differences were statistically significant (p < 0.0001). Signal-to-noise and contrast-to-noise ratios were best in S64; these differences also reached statistical significance. Image analysis, however, showed "non-inferiority” of scanner E regarding image quality. Conclusions: The first experience with the new scanner shows that new dose reduction techniques allow for up to 40 % dose reduction while still maintaining image quality at a diagnostically usable level
    corecore