174 research outputs found

    Progressing subglottic and tracheobronchial stenosis in a patient with CHARGE syndrome diagnosed in adulthood

    Get PDF
    AbstractA 33-year-old woman was admitted for a pseudocroup-like cough and wheezing after general anesthesia. Several months ago, she had undergone cardiac re-operation and turbinectomy, both of which had involved difficult intubations. Bronchoscopy indicated a pin-hall-like subglottic stenosis; therefore, emergency tracheotomy was performed. Six years later, a computed tomography scan demonstrated progressive stenosis of the entire circumference of the trachea and main bronchi. She died at 40 years. Her autopsy revealed marked tracheobronchial stenosis. She had many medical histories that had gone undiagnosed and had been clinically ill with only heart defects. She did not have coloboma but had microphthalmos, atresia choanae, retarded growth development, and deafness; thus, we diagnosed CHARGE syndrome that refers to multiple congenital anomalies, including airway abnormalities, which can lead to secondary complications such as traumatic stenosis after intubation. Physicians should have knowledge of this rare disease and should pay special attention to potential airway problems

    Genotoxicity of styrene oligomers extracted from polystyrene intended for use in contact with food

    Get PDF
    AbstractHere, we conducted in vitro genotoxicity tests to evaluate the genotoxicity of styrene oligomers extracted from polystyrene intended for use in contact with food. Styrene oligomers were extracted with acetone and the extract was subjected to the Ames test (OECD test guideline No. 471) and the in vitro chromosomal aberration test (OECD test guideline No. 473) under good laboratory practice conditions. The concentrations of styrene dimers and trimers in the concentrated extract were 540 and 13,431 ppm, respectively. Extraction with acetone provided markedly higher concentrations of styrene oligomers compared with extraction with 50% ethanol aqueous solution, which is the food simulant currently recommended for use in safety assessments of polystyrene by both the United States Food and Drug Administration and the European Food Safety Authority. And these high concentrations of styrene dimers and trimers were utilized for the evaluation of genotoxicity in vitro. Ames tests using five bacterial tester strains were negative both in the presence or absence of metabolic activation. The in vitro chromosomal aberration test using Chinese hamster lung cells (CHL/IU) was also negative. Together, these results suggest that the risk of the genotoxicity of styrene oligomers that migrate from polystyrene food packaging into food is very low

    GPU Based Software Correlators - Perspectives for VLBI2010

    Get PDF
    Caused by historical separation and driven by the requirements of the PC gaming industry, Graphics Processing Units (GPUs) have evolved to massive parallel processing systems which entered the area of non-graphic related applications. Although a single processing core on the GPU is much slower and provides less functionality than its counterpart on the CPU, the huge number of these small processing entities outperforms the classical processors when the application can be parallelized. Thus, in recent years various radio astronomical projects have started to make use of this technology either to realize the correlator on this platform or to establish the post-processing pipeline with GPUs. Therefore, the feasibility of GPUs as a choice for a VLBI correlator is being investigated, including pros and cons of this technology. Additionally, a GPU based software correlator will be reviewed with respect to energy consumption/GFlop/sec and cost/GFlop/sec

    History of Transcatheter Arterial Chemoembolization Predicts the Efficacy of Hepatic Arterial Infusion Chemotherapy in Hepatocellular Carcinoma Patients

    Get PDF
    This study sought to identify factors that are predictive of a therapeutic response to hepatic arterial infusion chemotherapy (HAIC) by focusing on the number of prior transcatheter arterial chemoembolization (TACE) sessions. To determine the parameters predicting a good response to HAIC, we retrospectively analyzed 170 patients with hepatocellular carcinoma (HCC) who received HAIC regimens comprising low-dose cisplatin combined with 5-fluorouracil (LFP) or cisplatin (CDDP) for the first time. In both the LFP and CDDP regimens, the response rates were significantly lower in patients with three or more prior TACE sessions than in those with two or fewer prior TACE sessions (LFP 57% versus 28%; p=0.01, CDDP 27% versus 6%; p=0.01). Multivariable logistic regression analysis revealed that the number of prior TACE sessions (≥ 3) was significantly associated with non-responder status (odds ratio 4.17, 95% Confidence Interval (CI) 1.76-9.86) in addition to the HAIC regimen. Multivariable analysis using the Cox proportional hazards model revealed that a larger number of prior TACE sessions (≥ 3) was a significant risk factor for survival (hazard ratio 1.60, 95% CI 1.12-2.29) in addition to Child-Pugh class, serum alpha-fetoprotein concentration, and maximum diameter of HCC. HCC patients who receive fewer prior TACE sessions (≤ 2) were found to be better responders to HAIC

    Helicobacter cinaedi-associated Carotid Arteritis

    Get PDF
    A 65-year-old Japanese man with bilateral carotid atherosclerosis presented with right neck pain and fever. Contrast-enhanced computed tomography suggested carotid arteritis, and carotid ultrasonography showed an unstable plaque. The patient developed a cerebral embolism, causing a transient ischemic attack. Helicobacter cinaedi was detected in blood culture, and H. cinaedi-associated carotid arteritis was diagnosed. Empirical antibiotic therapy was administered for 6 weeks. After readmission for recurrent fever, he was treated another 8 weeks. Although the relationship between H. cinaedi infection and atherosclerosis development remains unclear, the atherosclerotic changes in our patient’s carotid artery might have been attributable to H. cinaedi infection

    Prediction of the prognosis of advanced hepatocellular carcinoma by TERT promoter mutations in circulating tumor DNA

    Get PDF
    Background and Aim Human telomerase reverse transcriptase (TERT) promoter mutations were the most prevalent mutations in patients with hepatocellular carcinoma (HCC). We tried to detect the mutations with plasma circulating tumor DNA (ctDNA) in patients with advanced HCC and elucidated their clinical utility. Methods Circulating tumor DNA in plasma was extracted from 130 patients with advanced HCC who were treated with systemic chemotherapy (n = 86) or transcatheter arterial chemoembolization (n = 44), and TERT promoter mutations were examined with digital droplet polymerase chain reaction. The correlations between these mutations and the clinical outcome of patients were analyzed. Results Of the 130 patients examined, 71 patients (54.6%) were positive for TERT promoter mutations in ctDNA, of which 64 patients were −124bp G > A and 10 were −146bp G > A. The presence of TERT promoter mutations was correlated with large intrahepatic tumor size (P = 0.05) and high des‐gamma carboxyprothrombin (P = 0.005). Overall survival of the patients with the mutations was significantly shorter than those without them (P Conclusions TERT promoter mutations in ctDNA were associated with short survival and could be a valuable biomarker for predicting the prognosis of patients with advanced HCC

    Inversion channel diamond metaloxide-semiconductor field-effect transistor with normally off characteristics

    Get PDF
    We fabricated inversion channel diamond metal-oxide-semiconductor field-effect transistors (MOSFETs) with normally off characteristics. At present, Si MOSFETs and insulated gate bipolar transistors (IGBTs) with inversion channels are widely used because of their high controllability of electric power and high tolerance. Although a diamond semiconductor is considered to be a material with a strong potential for application in next-generation power devices, diamond MOSFETs with an inversion channel have not yet been reported. We precisely controlled the MOS interface for diamond by wet annealing and fabricated p-channel and planar-type MOSFETs with phosphorus-doped n-type body on diamond (111) substrate. The gate oxide of Al2O3 was deposited onto the n-type diamond body by atomic layer deposition at 300 °C. The drain current was controlled by the negative gate voltage, indicating that an inversion channel with a p-type character was formed at a high-quality n-type diamond body/Al2O3 interface. The maximum drain current density and the field-effect mobility of a diamond MOSFET with a gate electrode length of 5 μm were 1.6 mA/mm and 8.0 cm2/Vs, respectively, at room temperature. © The Author(s) 2016

    Predictive Factors for Successful Vaccination Against Hepatitis B Surface Antigen in Patients Who Have Undergone Orthotopic Liver Transplantation

    Get PDF
    Post-orthotopic liver transplantation (OLT) hepatitis B recurrence is well-controlled with a nucleos(t)ide analogue and hepatitis B immunoglobulin (HBIG) combination, but the high cost and the potential risk of unknown infection associated with HBIG remain unresolved issues. Low-cost recombinant hepatitis B virus (HBV) vaccine administration is a potential solution to these problems. We retrospectively analyzed the rate and predictive factors of HBV vaccine success in 49 post-OLT patients: liver cirrhosis-type B (LC-B), n=28 patients; acute liver failure-type B (ALF-B), n=8; and non-HBV-related end-stage liver disease (non-B ESLD) who received a liver from anti-hepatitis B core antibody-positive donors, n=13. A positive anti-hepatitis B surface antibody response was achieved in 29% (8/28) of the LC-B group, 88% (7/8) of the ALF-B group, and 44% (4/9) of the adult non-B ESLD group. All four non-B ESLD infants showed vaccine success. The predictive factors for a good response in LC-B were young age, marital donor, and high donor age. ALF-B and non-B ESLD infants are thus good vaccination candidates. LC-B patients with marital donors are also good candidates, perhaps because the donated liver maintains an efficient immune memory to HBV, as the donors had already been infected in adulthood and showed adequate anti-HBV immune responses

    Detection of a bright burst from the repeating FRB 20201124A at 2 GHz

    Full text link
    We present a detection of a bright burst from FRB 20201124A, which is one of the most active repeating FRBs, based on S-band observations with the 64-m radio telescope at the Usuda Deep Space Center/JAXA. This is the first FRB observed by using a Japanese facility. Our detection at 2 GHz in February 2022 is the highest frequency for this FRB and the fluence of >> 189 Jy ms is one of the brightest bursts from this FRB source. We place an upper limit on the spectral index α\alpha = -2.14 from the detection of the S band and non-detection of the X band at the same time. We compare an event rate of the detected burst with ones of the previous research, and suggest that the power-law of the luminosity function might be broken at lower fluence, and the fluences of bright FRBs distribute up to over 2 GHz with the power-law against frequency. In addition, we show the energy density of the burst detected in this work was comparable to the bright population of one-off FRBs. We propose that repeating FRBs can be as bright as one-off FRBs, and only their brightest bursts could be detected so some of repeating FRBs intrinsically might have been classified as one-off FRBs.Comment: 8 pages, 5 figures, accepted for publication in Publications of the Astronomical Society of Japan (PASJ
    corecore