5 research outputs found

    Five-Year Outcomes after Off-Pump or On-Pump Coronary-Artery Bypass Grafting.

    Get PDF
    BACKGROUND: We previously reported that there was no significant difference at 30 days or at 1 year in the rate of the composite outcome of death, stroke, myocardial infarction, or renal failure between patients who underwent coronary-artery bypass grafting (CABG) performed with a beating-heart technique (off-pump) and those who underwent CABG performed with cardiopulmonary bypass (on-pump). We now report the results at 5 years (the end of the trial). METHODS: A total of 4752 patients (from 19 countries) who had coronary artery disease were randomly assigned to undergo off-pump or on-pump CABG. For this report, we analyzed a composite outcome of death, stroke, myocardial infarction, renal failure, or repeat coronary revascularization (either CABG or percutaneous coronary intervention). The mean follow-up period was 4.8 years. RESULTS: There were no significant differences between the off-pump group and the on-pump group in the rate of the composite outcome (23.1% and 23.6%, respectively; hazard ratio with off-pump CABG, 0.98; 95% confidence interval [CI], 0.87 to 1.10; P=0.72) or in the rates of the components of the outcome, including repeat coronary revascularization, which was performed in 2.8% of the patients in the off-pump group and in 2.3% of the patients in the on-pump group (hazard ratio, 1.21; 95% CI, 0.85 to 1.73; P=0.29). The secondary outcome for the overall period of the trial - the mean cost in U.S. dollars per patient - also did not differ significantly between the off-pump group and the on-pump group (15,107and15,107 and 14,992, respectively; between-group difference, 115;95115; 95% CI, -697 to $927). There were no significant between-group differences in quality-of-life measures. CONCLUSIONS: In our trial, the rate of the composite outcome of death, stroke, myocardial infarction, renal failure, or repeat revascularization at 5 years of follow-up was similar among patients who underwent off-pump CABG and those who underwent on-pump CABG. (Funded by the Canadian Institutes of Health Research; CORONARY ClinicalTrials.gov number, NCT00463294 .)

    Effects of off-pump and on-pump coronary-artery bypass grafting at 1 year

    Full text link
    BACKGROUND: Previously, we reported that there was no significant difference at 30 days in the rate of a primary composite outcome of death, myocardial infarction, stroke, or new renal failure requiring dialysis between patients who underwent coronary-artery bypass grafting (CABG) performed with a beating-heart technique (off-pump) and those who underwent CABG performed with cardiopulmonary bypass (on-pump). We now report results on quality of life and cognitive function and on clinical outcomes at 1 year. METHODS: We enrolled 4752 patients with coronary artery disease who were scheduled to undergo CABG and randomly assigned them to undergo the procedure off-pump or on-pump. Patients were enrolled at 79 centers in 19 countries. We assessed quality of life and cognitive function at discharge, at 30 days, and at 1 year and clinical outcomes at 1 year. RESULTS: At 1 year, there was no significant difference in the rate of the primary composite outcome between off-pump and on-pump CABG (12.1% and 13.3%, respectively; hazard ratio with off-pump CABG, 0.91; 95% confidence interval [CI], 0.77 to 1.07; P=0.24). The rate of the primary outcome was also similar in the two groups in the period between 31 days and 1 year (hazard ratio, 0.79; 95% CI, 0.55 to 1.13; P=0.19). The rate of repeat coronary revascularization at 1 year was 1.4% in the off-pump group and 0.8% in the on-pump group (hazard ratio, 1.66; 95% CI, 0.95 to 2.89; P=0.07). There were no significant differences between the two groups at 1 year in measures of quality of life or neurocognitive function. CONCLUSIONS: At 1 year after CABG, there was no significant difference between off-pump and on-pump CABG with respect to the primary composite outcome, the rate of repeat coronary revascularization, quality of life, or neurocognitive function. (Funded by the Canadian Institutes of Health Research; CORONARY ClinicalTrials.gov number, NCT00463294.)
    corecore