16 research outputs found

    Polychromatic immunophenotypic characterization of T cell profiles among HIV-infected patients experiencing immune reconstitution inflammatory syndrome (IRIS)

    Get PDF
    Abstract Objective To immunophenotype CD4+ and CD8+ T cell sub-populations in HIV-associated immune reconstitution inflammatory syndrome (IRIS). Design Nested case-control immunological study. Methods ART-naïve HIV-infected patients were prospectively observed for IRIS during the first 6 months of ART. Twenty-two IRIS cases and 22 ART-duration matched controls were sampled for T cell immunophenotyping. Results IRIS cases demonstrated significantly lower CD4 cell counts compared to controls (baseline: 79 versus 142, p = 0.02; enrollment: 183 versus 263, p = 0.05, respectively) with no differences in HIV RNA levels. Within CD4+T cells, cases exhibited more of an effector memory phenotype compared to controls (40.8 versus 27.0%, p = 0.20), while controls trended towards a central memory phenotype (43.8 versus 30.8%, p = 0.07). Within CD8+ T cells, controls exhibited more central memory (13.9 versus 7.81%, p = 0.01, respectively) and effector (13.2 versus 8.8%, p = 0.04, respectively) phenotypes compared to cases, whereas cases demonstrated more terminal effectors than controls (28.8 versus 15.1%, p = 0.05). Cases demonstrated increased activation of CD8+ T cell effector memory, terminal effector, and effector subsets than controls (p = 0.04, 0.02, and 0.02, respectively). Conclusion CD4+ and CD8+ T cell subset maturational phenotypes were heterogeneous among IRIS cases and controls. However, IRIS cases demonstrated significant increases in activation of CD8+ T cell effector subpopulations

    Modeling flow cytometry data for cancer vaccine immune monitoring

    Get PDF
    Flow cytometry (FCM) is widely used in cancer research for diagnosis, detection of minimal residual disease, as well as immune monitoring and profiling following immunotherapy. In all these applications, the challenge is to detect extremely rare cell subsets while avoiding spurious positive events. To achieve this objective, it helps to be able to analyze FCM data using multiple markers simultaneously, since the additional information provided often helps to minimize the number of false positive and false negative events, hence increasing both sensitivity and specificity. However, with manual gating, at most two markers can be examined in a single dot plot, and a sequential strategy is often used. As the sequential strategy discards events that fall outside preceding gates at each stage, the effectiveness of the strategy is difficult to evaluate without laborious and painstaking back-gating. Model-based analysis is a promising computational technique that works using information from all marker dimensions simultaneously, and offers an alternative approach to flow analysis that can usefully complement manual gating in the design of optimal gating strategies. Results from model-based analysis will be illustrated with examples from FCM assays commonly used in cancer immunotherapy laboratories

    Immunization with Cocktail of HIV-Derived Peptides in Montanide ISA-51 Is Immunogenic, but Causes Sterile Abscesses and Unacceptable Reactogenicity

    Get PDF
    BACKGROUND: A peptide vaccine was produced containing B and T cell epitopes from the V3 and C4 Envelope domains of 4 subtype B HIV-1 isolates (MN, RF, CanO, & Ev91). The peptide mixture was formulated as an emulsion in incomplete Freund's adjuvant (IFA). METHODS: Low-risk, healthy adult subjects were enrolled in a randomized, placebo-controlled dose-escalation study, and selected using criteria specifying that 50% in each study group would be HLA-B7+. Immunizations were scheduled at 0, 1, and 6 months using a total peptide dose of 1 or 4 mg. Adaptive immune responses in16 vaccine recipients and two placebo recipients after the 2nd immunization were evaluated using neutralization assays of sera, as well as ELISpot and ICS assays of cryopreserved PBMCs to assess CD4 and CD8 T-cell responses. In addition, (51)Cr release assays were performed on fresh PBMCs following 14-day stimulation with individual vaccine peptide antigens. RESULTS: 24 subjects were enrolled; 18 completed 2 injections. The study was prematurely terminated because 4 vaccinees developed prolonged pain and sterile abscess formation at the injection site-2 after dose 1, and 2 after dose 2. Two other subjects experienced severe systemic reactions consisting of headache, chills, nausea, and myalgia. Both reactions occurred after the second 4 mg dose. The immunogenicity assessments showed that 6/8 vaccinees at each dose level had detectable MN-specific neutralizing (NT) activity, and 2/7 HLA-B7+ vaccinees had classical CD8 CTL activity detected. However, using both ELISpot and ICS, 8/16 vaccinees (5/7 HLA-B7+) and 0/2 controls had detectable vaccine-specific CD8 T-cell responses. Subjects with moderate or severe systemic or local reactions tended to have more frequent T cell responses and higher antibody responses than those with mild or no reactions. CONCLUSIONS: The severity of local responses related to the formulation of these four peptides in IFA is clinically unacceptable for continued development. Both HIV-specific antibody and T cell responses were induced and the magnitude of response correlated with the severity of local and systemic reactions. If potent adjuvants are necessary for subunit vaccines to induce broad and durable immune responses, careful, incremental clinical evaluation is warranted to minimize the risk of adverse events. TRIAL REGISTRATION: ClinicalTrials.gov NCT00000886

    Standardization of cytokine flow cytometry assays

    Get PDF
    BACKGROUND: Cytokine flow cytometry (CFC) or intracellular cytokine staining (ICS) can quantitate antigen-specific T cell responses in settings such as experimental vaccination. Standardization of ICS among laboratories performing vaccine studies would provide a common platform by which to compare the immunogenicity of different vaccine candidates across multiple international organizations conducting clinical trials. As such, a study was carried out among several laboratories involved in HIV clinical trials, to define the inter-lab precision of ICS using various sample types, and using a common protocol for each experiment (see additional files online). RESULTS: Three sample types (activated, fixed, and frozen whole blood; fresh whole blood; and cryopreserved PBMC) were shipped to various sites, where ICS assays using cytomegalovirus (CMV) pp65 peptide mix or control antigens were performed in parallel in 96-well plates. For one experiment, antigens and antibody cocktails were lyophilised into 96-well plates to simplify and standardize the assay setup. Results (CD4(+)cytokine(+ )cells and CD8(+)cytokine(+ )cells) were determined by each site. Raw data were also sent to a central site for batch analysis with a dynamic gating template. Mean inter-laboratory coefficient of variation (C.V.) ranged from 17–44% depending upon the sample type and analysis method. Cryopreserved peripheral blood mononuclear cells (PBMC) yielded lower inter-lab C.V.'s than whole blood. Centralized analysis (using a dynamic gating template) reduced the inter-lab C.V. by 5–20%, depending upon the experiment. The inter-lab C.V. was lowest (18–24%) for samples with a mean of >0.5% IFNγ + T cells, and highest (57–82%) for samples with a mean of <0.1% IFNγ + cells. CONCLUSION: ICS assays can be performed by multiple laboratories using a common protocol with good inter-laboratory precision, which improves as the frequency of responding cells increases. Cryopreserved PBMC may yield slightly more consistent results than shipped whole blood. Analysis, particularly gating, is a significant source of variability, and can be reduced by centralized analysis and/or use of a standardized dynamic gating template. Use of pre-aliquoted lyophilized reagents for stimulation and staining can provide further standardization to these assays

    Nine-color flow cytometry for accurate measurement of T cell subsets and cytokine responses. Part I: Panel design by an empiric approach.

    No full text
    Polychromatic flow cytometry offers the unprecedented ability to investigate multiple antigens per cell. Unfortunately, unwanted spectral overlaps and compensation problems increase when more than four colors are used, but these problems can be minimized if staining combinations are chosen carefully. We used an empiric approach to design, test and identify six-color T cell immunophenotyping reagent panels that can be expanded to include three or more functional or other markers in the FITC, PE, and APC channels without significant spectral limitations. Thirty different six-color T cell surface antigen reagent panels were constructed to identify major T cell subsets and maturational subtypes as defined by CCR7 and CD45RA expression, while excluding monocytes, B and non-viable cells. Staining performance of each panel was compared on cryopreserved cells from a single healthy donor recorded on a multiparameter cell sorter. Ten of the thirty reagent panels offered reliable resolution of T cell major and maturational surface markers. Of these, two panels were selected that showed the least spectral overlap and resulting background increase in the FITC, PE, and APC channels. These channels were left unoccupied for inclusion of additional phenotypic or functional markers, such as cytokines. Careful reagent titration and testing of multiple candidate panels are necessary to ensure quality results in multiparametric measurements

    Nine-color flow cytometry for accurate measurement of T cell subsets and cytokine responses. Part II: Panel performance across different instrument platforms.

    No full text
    Cellular immune responses elicited by vaccination are complex and require polychromatic analysis to accurately characterize the phenotype and function of rare, responding cells. Technical challenges and a lack of instrument standardization between research sites have limited the application of polychromatic cytometry in multicenter clinical trials. Two previously developed six-color T cell subset immunophenotyping reagent panels deliberately designed to accommodate three additional low frequency functional measurements were compared for their reproducibility of staining across three different flow cytometers. We repeatedly measured similar T cell subset frequencies between the two reagent panels and across the three different cytometers. Spectral overlap reduced sensitivity in two of the three open measurement channels (PE [IL-2] and APC [IFN gamma]) for one reagent combination, particularly in subsets with low cytokine expression. There was no significant interassay variation for measurements across instrument platforms. Careful panel design will identify reagent combinations that minimize spectral spillover into channels reserved for cytokine measurement and comparable results can be achieved using different cytometers, however, it is important to establish standardized quality control procedures for each instrument to minimize variation between cytometers
    corecore