56 research outputs found

    Scattering Suppression from Arbitrary Objects in Spatially-Dispersive Layered Metamaterials

    Get PDF
    Concealing objects by making them invisible to an external electromagnetic probe is coined by the term cloaking. Cloaking devices, having numerous potential applications, are still face challenges in realization, especially in the visible spectral range. In particular, inherent losses and extreme parameters of metamaterials required for the cloak implementation are the limiting factors. Here, we numerically demonstrate nearly perfect suppression of scattering from arbitrary shaped objects in spatially dispersive metamaterial acting as an alignment-free concealing cover. We consider a realization of a metamaterial as a metal-dielectric multilayer and demonstrate suppression of scattering from an arbitrary object in forward and backward directions with perfectly preserved wavefronts and less than 10% absolute intensity change, despite spatial dispersion effects present in the composite metamaterial. Beyond the usual scattering suppression applications, the proposed configuration may serve as a simple realisation of scattering-free detectors and sensors

    Retrieval of Effective Parameters of Subwavelength Periodic Photonic Structures

    Get PDF
    We revisit the standard Nicolson–Ross–Weir method of effective permittivity and permeability restoration of photonic structures for the case of subwavelength metal-dielectric multilayers. We show that the direct application of the standard method yields a false zero-epsilon point and an associated spurious permeability resonance. We show how this artifact can be worked around by the use of the cycle shift operator to the periodic multilayer in question

    Femtomolar detection of the heart failure biomarker NT-proBNP in artificial saliva using an immersible liquid-gated aptasensor with reduced graphene oxide

    Full text link
    Measuring NT-proBNP biomarker is recommended for preliminary diagnostics of the heart failure. Recent studies suggest a possibility of early screening of biomarkers in saliva for non-invasive identification of cardiac diseases at the point-of-care. However, NT-proBNP concentrations in saliva can be thousand time lower than in blood plasma, going down to pg/mL level. To reach this level, we developed a label-free aptasensor based on a liquid-gated field effect transistor using a film of reduced graphene oxide monolayer (rGO-FET) with immobilized NT-proBNP specific aptamer. We found that, depending on ionic strength of tested solutions, there were different levels of correlation in responses of electrical parameters of the rGO-FET aptasensor, namely, the Dirac point shift and transconductance change. The correlation in response to NT-proBNP was high for 1.6 mM phosphate-buffered saline (PBS) and zero for 16 mM PBS in a wide range of analyte concentrations, varied from 1 fg/mL to 10 ng/mL. The effects of transconductance and Dirac point shift in PBS solutions of different concentrations are discussed. The biosensor exhibited a high sensitivity for both transconductance (2 uS/decade) and Dirac point shift (2.3 mV/decade) in diluted PBS with the linear range from 10 fg/mL to 1 pg/mL. The aptasensor performance has been also demonstrated in undiluted artificial saliva with the achieved limit of detection down to 41 fg/mL (~4.6 fM)

    Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    Get PDF
    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%

    Collins and Sivers asymmetries in muonproduction of pions and kaons off transversely polarised protons

    Get PDF
    Measurements of the Collins and Sivers asymmetries for charged pions and charged and neutral kaons produced in semi-inclusive deep-inelastic scattering of high energy muons off transversely polarised protons are presented. The results were obtained using all the available COMPASS proton data, which were taken in the years 2007 and 2010. The Collins asymmetries exhibit in the valence region a non-zero signal for pions and there are hints of non-zero signal also for kaons. The Sivers asymmetries are found to be positive for positive pions and kaons and compatible with zero otherwise. © 2015

    Transverse optic modes in monoclinic α-Bi2O3

    No full text
    Measurements of infrared polarized reflectance spectra of single-crystal α-Bi2O3 have been made at room temperature in the wavelength range from 30 to 4000 cm−1 for different orientations of the wave vector k and the electric field E of the incident radiation relative to the crystallographic axes. On the basis of Born and Huang’s theory, relations between characteristics of TO modes of the monoclinic lattice and the reflectivity for the orientations used are established. Dipole momentum orientations, frequencies, strengths and linewidths of almost all of the IR-active modes predicted by the factor-group analysis for the α-Bi2O3 were determined. Good agreement between experimentally measured and model spectra was achieved. It was shown that in order to obtain reliable values of parameters of Bu modes three spectra for different orientations of E in the ac-plane should be fitted simultaneously. It was found that Bu modes have significantly greater intensities than Au modes. The effect of the rotation of the principal dielectric axes within the ac-plane was studied

    Polarized infrared reflectance spectra of single crystal α-Bi<sub>2</sub>O<sub>3</sub>

    No full text
    Polarized IR reflectance spectra of monoclinic single crystal ~-Bi20 ~ for different directions of the wave vector k and the electric field E of the incident radiation have been measured in a wide temperature range (25-400 K). A significant dependence of the spectrum shape on the direction of the vector E within the ac-plane was observed. Frequencies, strengths, widths and polarizations of the TO modes were restored using the Lorentz dispersion model extended for the monoclinic crystal lattice. Remarkable distinction between intensities of Au-and B=-modes is observed
    corecore