11 research outputs found

    Sex-specific aortic valve calcifications in patients undergoing transcatheter aortic valve implantation

    Get PDF
    To study sex-specific differences in the amount and distribution of aortic valve calcification (AVC) and to correlate the AVC load with paravalvular leakage (PVL) post-transcatheter aortic valve intervention (TAVI). This registry included 1801 patients undergoing TAVI with a Sapien3 or Evolut valve in two tertiary care institutions. Exclusion criteria encompassed prior aortic valve replacement, suboptimal multidetector computed tomography (MDCT) quality, and suboptimal transthoracic echocardiography images. Calcium content and distribution were derived from MDCT. In this study, the median age was 81.7 (25th–75th percentile 77.5–85.3) and 54% male. Men, compared to women, were significantly younger [81.2 (25th–75th percentile 76.5–84.5) vs. 82.4 (78.2–85.9), P ≤ 0.01] and had a larger annulus area [512 mm 2 (25th–75th percentile 463–570) vs. 405 mm 2 (365–454), P < 0.01] and higher Agatston score [2567 (25th–75th percentile 1657–3913) vs. 1615 (25th–75th percentile 905–2484), P < 0.01]. In total, 1104 patients (61%) had none-trace PVL, 648 (36%) mild PVL, and 49 (3%) moderate PVL post-TAVI. There was no difference in the occurrence of moderate PVL between men and women (3% vs. 3%, P = 0.63). Cut-off values for the Agatston score as predictor for moderate PVL based on the receiver-operating characteristic curve were 4070 (sensitivity 0.73, specificity 0.79) for men and 2341 (sensitivity 0.74, specificity 0.73) for women. AVC is a strong predictor for moderate PVL post-TAVI. Although the AVC load in men is higher compared to women, there is no difference in the incidence of moderate PVL. Sex-specific Agatston score cut-offs to predict moderate PVL were almost double as high in men vs. women

    Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems: The INTERSECT registry.

    Get PDF
    BACKGROUND New permanent pacemaker implantation (new-PPI) remains a compelling issue after Transcatheter Aortic Valve Replacement (TAVR). Previous studies reported the relationship between a short MS length and the new-PPI post-TAVR with a self-expanding THV. However, this relationship has not been investigated in different currently available THV. Therefore, the aim of this study was to investigate the association between membranous septum (MS)-length and new-PPI after TAVR with different Transcatheter Heart Valve (THV)-platforms. METHODS We included patients with a successful TAVR-procedure and an analyzable pre-procedural multi-slice computed tomography. MS-length was measured using a standardized methodology. The primary endpoint was the need for new-PPI within 30 days after TAVR. RESULTS In total, 1811 patients were enrolled (median age 81.9 years [IQR 77.2-85.4], 54% male). PPI was required in 275 patients (15.2%) and included respectively 14.2%, 20.7% and 6.3% for Sapien3, Evolut and ACURATE-THV(p ​< ​0.01). Median MS-length was significantly shorter in patients with a new-PPI (3.7 ​mm [IQR 2.2-5.1] vs. 4.1 ​mm [IQR 2.8-6.0], p ​= ​<0.01). Shorter MS-length was a predictor for PPI in patients receiving a Sapien3 (OR 0.87 [95% CI 0.79-0.96], p ​= ​<0.01) and an Evolut-THV (OR 0.91 [95% CI 0.84-0.98], p ​= ​0.03), but not for an ACURATE-THV (OR 0.99 [95% CI 0.79-1.21], p ​= ​0.91). By multivariable analysis, first-degree atrioventricular-block (OR 2.01 [95% CI 1.35-3.00], p = <0.01), right bundle branch block (OR 8.33 [95% CI 5.21-13.33], p = <0.01), short MS-length (OR 0.89 [95% CI 0.83-0.97], p ​< ​0.01), annulus area (OR 1.003 [95% CI 1.001-1.005], p ​= ​0.04), NCC implantation depth (OR 1.13 [95% CI 1.07-1.19] and use of Evolut-THV(OR 1.54 [95% CI 1.03-2.27], p ​= ​0.04) were associated with new-PPI. CONCLUSION MS length was an independent predictor for PPI across different THV platforms, except for the ACURATE-THV. Based on our study observations within the total cohort, we identified 3 risk groups by MS length: MS length ≤3 ​mm defined a high-risk group for PPI (>20%), MS length 3-7 ​mm intermediate risk for PPI (10-20%) and MS length > 7 ​mm defined a low risk for PPI (<10%). Anatomy-tailored-THV-selection may mitigate the need for new-PPI in patients undergoing TAVR

    Crowdsourcing a cyclist perspective on suggested recreational paths in real-world networks

    No full text
    Routing and navigation services for leisure activities are conditioned by special needs and trade-offs. The advent of online communities and large crowdsourced datasets offers opportunities to improve the adoption of a user's perspective in these suggested paths. This paper focuses on achieving two goals. First, the presented methodology analyses a dataset of 190,610 historical GPS traces to gain insights into the appreciation or attractiveness of each edge in a real-world network for a specific leisure activity (i.e. road cycling). Second, as literature on these leisure activities is still sparse, we want to create a thorough understanding of the activities at hand for future work. An appreciation model is proposed and the spread of this score is analyzed in shortest-path alternatives of popular routing engines for this activity. This analysis successfully discriminates these shortest paths based on the scoring value and three morphological parameters of the path. However, the robustness of the model should be improved to ensure the viability of the proposed approach in future work. More specifically, further research on the local optimality of the route choices will be imperative

    Sex-Specific Differences in Aortic Valve Calcification Between Bicuspid and Tricuspid Severe Aortic Stenosis

    No full text
    Sex-specific thresholds of aortic valve calcification (AVC) correlate with aortic stenosis (AS) and may complement echocardiography to determine AS severity. Importantly, current guideline-recommended thresholds of AVC scores derived by multislice computed tomography do not distinguish between bicuspid and tricuspid aortic valves. The objective of this study was to evaluate the sex-specific differences in the amount of AVC in patients with severe AS and tricuspid (TAV) versus bicuspid (BAV) aortic valve morphologies, retrospectively evaluated by 2 tertiary care institutions. The inclusion criteria comprised patients with severe AS and a left ventricular ejection fraction ≥50% and suitable imaging examinations. The study included 1,450 patients (723 men; 49.9%) with severe AS, including 1,335 patients with TAV (92.1%) and 115 with BAV (17.9%). The calculated Agatston score was higher in BAV patients (men: BAV 4,358 [2,644 to 6,005] AU vs TAV 2,643 [1,727 to 3,794] AU, p <0.01; women: BAV 2,174 [1,330 to 4,378] AU vs TAV 1,703 [964 to 2,534] AU, p <0.01), also when indexed for valve dimensions and body surface area (men: BAV 2,227 [321 to 3,105] AU/m2 vs TAV 1,333 [872 to 1,913] AU/m2, p <0.01; women: BAV 1,326 [782 to 2,148] AU/m2 vs TAV 930 [546 to 1,456] AU/m2, p <0.01). Differences between the BAV- and TAV-derived Agatston score was more prominent in concordant severe AS. In conclusion, sex-specific Agatston scores in severe AS were approximately 1/3 higher in patients with BAV than in patients with TAV for both women and men. Optimal AVC thresholds should be adjusted for BAV, also respecting considerable prognostic implications

    Leaflet Thickening and Motion After Transcatheter Aortic Valve Replacement: Design and Rationale of the Rotterdam Edoxaban Trial

    Get PDF
    Background: Multislice computed tomography (MSCT) may reveal hypo-attenuated leaflet thickening (HALT) and/or reduced leaflet motion (RELM) in approximately 15 % of patients after transcatheter aortic valve replacement (TAVR). These supposedly thrombogenic phenomena may be associated with neurological events and increased transprosthetic gradients. It is unclear whether oral anticoagulant therapy -specifically a factor Xa inhibitor- could affect the incidence of HALT/RELM. Study design: The Rotterdam EDOXaban (REDOX) trial is an investigator-initiated, single-center, prospective registry in which 100 patients with no formal indication for oral anticoagulant drugs or dual antiplatelet therapy, will receive a 3-month treatment with edoxaban, followed by a MSCT to detect HALT/RELM. The primary endpoint is the incidence of HALT at 3-months follow-up. Secondary endpoints include the incidence of RELM at 3 months; change in transprosthetic gradients at 1 year and the clinical composite endpoint of all-cause death, myocardial infarction (MI), ischemic stroke, systemic thromboembolism, valve thrombosis and major bleeding (International Society on Thrombosis and Hemostasis [ISTH] definition) at 1 year follow up. The study is powered to demonstrate with 90 % statistical power and a 0.025 alpha a 4 % incidence of HALT with edoxaban as compared to the expected 15 % rate with an antiplatelet regimen and will enroll 100 patients to account for loss of follow-up or CT-drop out. Conclusion: The REDOX trial will investigate the short-term effect of an Xa-inhibitor on the incidence of HALT after TAVR. (ClinicalTrials.gov Identifier: NCT04171726)

    Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems: The INTERSECT registry

    No full text
    Background: New permanent pacemaker implantation (new-PPI) remains a compelling issue after Transcatheter Aortic Valve Replacement (TAVR). Previous studies reported the relationship between a short MS length and the new-PPI post-TAVR with a self-expanding THV. However, this relationship has not been investigated in different currently available THV. Therefore, the aim of this study was to investigate the association between membranous septum (MS)-length and new-PPI after TAVR with different Transcatheter Heart Valve (THV)-platforms. Methods: We included patients with a successful TAVR-procedure and an analyzable pre-procedural multi-slice computed tomography. MS-length was measured using a standardized methodology. The primary endpoint was the need for new-PPI within 30 days after TAVR. Results: In total, 1811 patients were enrolled (median age 81.9 years [IQR 77.2–85.4], 54% male). PPI was required in 275 patients (15.2%) and included respectively 14.2%, 20.7% and 6.3% for Sapien3, Evolut and ACURATE-THV(p ​20%), MS length 3–7 ​mm intermediate risk for PPI (10–20%) and MS length > 7 ​mm defined a low risk for PPI (<10%). Anatomy-tailored-THV-selection may mitigate the need for new-PPI in patients undergoing TAVR

    Diffusion-weighted MRI to assess response to chemoradiotherapy in rectal cancer:main interpretation pitfalls and their use for teaching

    Get PDF
    To establish the most common image interpretation pitfalls for non-expert readers using diffusion-weighted imaging (DWI) to assess response to chemoradiotherapy in patients with rectal cancer and to explore the use of these pitfalls in an expert teaching setting. Two independent non-expert readers (R1 and R2) scored the restaging DW MRI scans (b1,000 DWI, in conjunction with ADC maps and T2-W MRI scans for anatomical reference) in 100 patients for the likelihood of a complete response versus residual tumour using a five-point confidence score. The readers received expert feedback and the final response outcome for each case. The supervising expert documented any potential interpretation errors/pitfalls discussed for each case to identify the most common pitfalls. The most common pitfalls were the interpretation of low signal on the ADC map, small susceptibility artefacts, T2 shine-through effects, suboptimal sequence angulation and collapsed rectal wall. Diagnostic performance (area under the ROC curve) was 0.78 (R1) and 0.77 (R2) in the first 50 patients and 0.85 (R1) and 0.85 (R2) in the final 50 patients. Five main image interpretation pitfalls were identified and used for teaching and feedback. Both readers achieved a good diagnostic performance with an AUC of 0.85. aEuro cent Fibrosis appears hypointense on an ADC map and should not be mistaken for tumour. aEuro cent Susceptibility artefacts on rectal DWI are an important potential pitfall. aEuro cent T2 shine-through on rectal DWI is an important potential pitfall. aEuro cent These pitfalls are useful to teach non-experts how to interpret rectal DW
    corecore