96 research outputs found

    Serum IgG4 as a biomarker reflecting pathophysiology and post-operative recurrence in chronic rhinosinusitis

    Get PDF
    Background: Type 2 chronic rhinosinusitis (CRS), especially eosinophilic CRS (ECRS), is an intractable upper airway inflammatory disease. Establishment of serum biomarkers reflecting the pathophysiology of CRS is desirable in a clinical setting. As IgG4 production is regulated by type 2 cytokines, we sought to determine whether serum IgG4 levels can be used as a biomarker for CRS. Methods: Association between the serum IgG4 levels and clinicopathological factors was analyzed in 336 CRS patients. Receiver operating characteristics (ROC) analysis was performed to determine the cut-off value of serum IgG4 levels that can be used to predict the post-operative recurrence. Results: Serum IgG4 levels were significantly higher in patients with moderate to severe ECRS versus those with non to mild ECRS. The levels were also significantly higher in asthmatic patients and patients exhibiting recurrence after surgery compared to controls. ROC analysis determined that the best cut-off value for the serum IgG4 level to predict the post-operative recurrence was 95 mg/dL. The corresponding sensitivity and specificity were 39.7% and 80.5%, respectively. When we combined the two cut-off values for the serum IgG4 and periostin, patients with high serum levels of either IgG4 or periostin exhibited a high post-operative recurrence (OR: 3.95) as compared to patients having low serum levels of both IgG4 and periostin. Conclusions: The present results demonstrate that the serum IgG4 level is associated with disease severity and post-operative course in CRS. In particular, the combination of serum IgG4 and periostin could be a novel biomarker that predicts post-operative recurrence

    Reliability and validity of the patient disability-oriented diagnostic nomenclature system for prosthetic dentistry

    Get PDF
    Purpose: The Japan Prosthodontic Society (JPS) has proposed a new diagnostic nomenclature system (DNS), based on pathogenesis and etiology, to facilitate and improve prosthodontic treatment. This systemspecifies patient disability and the causative factor (i.e. ‘‘B (disability) caused by A (causative factor)’’). The purpose of this study was to examine the reliability and validity of this DNS. Study selection: The JPS Clinical Guideline Committee assessed mock patient charts and formulated disease names using the new DNS. Fifty validators, comprising prosthodontic specialists and dental residents, made diagnoses using the same patient charts. Reliability was evaluated as the consistency of the disease names among the validators, and validity was evaluated using the concordance rate of the disease names with the reference disease names. Results: Krippendorff’s α was 0.378 among all validators, 0.370 among prosthodontic specialists, and 0.401 among dental hospital residents. Krippendorff’s α for 10 validators (3 specialists and 7 residents) with higher concordance rates was 0.524. Two validators (1 specialist and 1 resident) with the highest concordance rates had a Krippendorff’s α of 0.648. Common disease names had higher concordance rates, while uncommon disease names showed lower concordance rates. These rates did not show correlation with clinical experience of the validator or time taken to devise the disease name. Conclusions: High reliability was not found among all validators; however, validators with higher concordance rates showed better reliability. Furthermore, common disease names had higher concordance rates. These findings indicate that the new DNS for prosthodontic dentistry exhibits clinically acceptable reliability and validity

    AN INFORMATION-THEORETIC APPROACH TO PARTIAL REINFORCEMENT EFFECT

    No full text

    In memory of Akira Tonomura: physicist and electron microscopist

    No full text

    Surface Plasmon Excitation and Localization by Metal-Coated Axicon Prism

    No full text
    Collimated Gaussian beams are efficiently localized at the apex of a metal-coated axicon prism by surface plasmon excitations. We observed the light scattered at the apex and the light reflected by the prism. Intense scattered light was observed with the radial polarization incidence. Further, each incidence of the radial, azimuthal, and linear polarizations provided field distributions of bright and dark intensities in the reflected images according to the surface plasmon excitation. We have demonstrated that surface plasmon waves are excited at the sides of the prism in the Kretschmann configuration and that they converge to its apex

    Evaluation of Low-contrast Detectability in Low-dose Chest Computed Tomography

    No full text
    corecore