3 research outputs found

    Π‘Ρ–ΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΈ Π² діагностиці Ρ…Π²ΠΎΡ€ΠΎΠ± ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π°

    Get PDF
    The chronic course of periodontitis and gingivitis affects up to 80 % of the adult population, making them one of the most common diseases of mankind. The disease is initiated by the accumulation of bacteria along the gingival margin and in the space between the gingival tissue and the teeth. The absence of an acute pain clinic for periodontal diseases is one of the main reasons for the low level of patients seeking dental care. Diagnosis of periodontal disease, as a rule, is carried out by a dentist, it includes a visual examination of the gum tissue and a number of other protocol procedures, including additional diagnostic methods – a clinical assessment of the roentgenogram. At the same time, conventional clinical and radiographic methods for periodontal diagnostics are capable of only a retrospective diagnosis, they cannot detect or predict the activity of periodontitis. For these reasons, in recent years, potential biomarkers for the diagnosis of periodontal tissue diseases have been actively investigated. The source of biomarkers, in the first place, are considered gingival fluid and saliva, such as those that are in direct contact with the affected tissues. Given the foregoing, it seems appropriate to review the literature on biomarkers of gingival fluid and saliva used to diagnose periodontal diseases and the possibility of developing easy-to-use test methods for their early diagnosis. The aim of the study – to evaluate the prospects of using biomarkers in dental practice, in particular in the diagnosis of parathon tissue pathology, including peri-implant pathology, based on the analysis of literature data. Materials and Methods. The study used biblical and analytical methods. Results and Discussion. The sources of scientific and medical information on the application of biomarkers in the diagnosis of periodontal diseases are analyzed and processed. Conclusions. Despite the fact that the diagnostic value of oral fluids is recognized and there is a significant number of potential biomarkers, the studies conducted to date have proved inadequate to provide clinically reliable and useful information for practitioners in terms of more accurate diagnosis and treatment planning.Π₯роничСскоС Ρ‚Π΅Ρ‡Π΅Π½ΠΈΠ΅ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚ΠΈΡ‚Π° ΠΈ Π³ΠΈΠ½Π³ΠΈΠ²ΠΈΡ‚Π° ΠΏΠΎΡ€Π°ΠΆΠ°Π΅Ρ‚ Π΄ΠΎ 80 % взрослого насСлСния, ΡΡ‚Π°Π²ΡˆΠΈ ΠΎΠ΄Π½ΠΎΠΉ ΠΈΠ· самых распространСнных Π±ΠΎΠ»Π΅Π·Π½Π΅ΠΉ чСловСчСства. ЗаболСвания инициируСтся Π½Π°ΠΊΠΎΠΏΠ»Π΅Π½ΠΈΠ΅ΠΌ Π±Π°ΠΊΡ‚Π΅Ρ€ΠΈΠΉ вдоль дСснСвого края ΠΈ Π² пространствС ΠΌΠ΅ΠΆΠ΄Ρƒ дСснСвыми тканями ΠΈ Π·ΡƒΠ±Π°ΠΌΠΈ. ΠžΡ‚ΡΡƒΡ‚ΡΡ‚Π²ΠΈΠ΅ ΠΊΠ»ΠΈΠ½ΠΈΠΊΠΈ острой Π±ΠΎΠ»ΠΈ ΠΏΡ€ΠΈ заболСваниях ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π° являСтся ΠΎΠ΄Π½ΠΎΠΉ ΠΈΠ· основных ΠΏΡ€ΠΈΡ‡ΠΈΠ½ Π½ΠΈΠ·ΠΊΠΎΠ³ΠΎ уровня ΠΎΠ±Ρ€Π°Ρ‰Π΅Π½ΠΈΠΉ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² Π·Π° стоматологичСской ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ. Диагностику Π·Π°Π±ΠΎΠ»Π΅Π²Π°Π½ΠΈΠΉ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π°, ΠΊΠ°ΠΊ ΠΏΡ€Π°Π²ΠΈΠ»ΠΎ, ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΡ‚ Π²Ρ€Π°Ρ‡-стоматолог. Она Π²ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚ Π²ΠΈΠ·ΡƒΠ°Π»ΡŒΠ½Ρ‹ΠΉ осмотр Ρ‚ΠΊΠ°Π½Π΅ΠΉ дСсСн ΠΈ ряд Π΄Ρ€ΡƒΠ³ΠΈΡ… ΠΏΡ€ΠΎΡ‚ΠΎΠΊΠΎΠ»ΡŒΠ½Ρ‹Ρ… ΠΏΡ€ΠΎΡ†Π΅Π΄ΡƒΡ€, Π² Ρ‚ΠΎΠΌ числС Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ… ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠ² диагностики – ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΡƒΡŽ ΠΎΡ†Π΅Π½ΠΊΡƒ Ρ€Π΅Π½Ρ‚Π΅Π½ΠΎΠ³Ρ€Π°ΠΌΠΌΡ‹. Π’ Ρ‚ΠΎ ΠΆΠ΅ врСмя, ΠΎΠ±Ρ‹Ρ‡Π½Ρ‹Π΅ клиничСскиС ΠΈ рСнтгСнографичСскиС ΠΌΠ΅Ρ‚ΠΎΠ΄Ρ‹ диагностики ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π° способны лишь ΠΊ рСтроспСктивному Π΄ΠΈΠ°Π³Π½ΠΎΠ·Ρƒ, ΠΎΠ½ΠΈ Π½Π΅ ΠΌΠΎΠ³ΡƒΡ‚ ΠΎΠ±Π½Π°Ρ€ΡƒΠΆΠΈΡ‚ΡŒ ΠΈΠ»ΠΈ ΠΏΡ€Π΅Π΄ΡΠΊΠ°Π·Π°Ρ‚ΡŒ Π°ΠΊΡ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚ΠΈΡ‚Π°. ΠŸΠΎΡΡ‚ΠΎΠΌΡƒ Π² послСдниС Π³ΠΎΠ΄Ρ‹ Π°ΠΊΡ‚ΠΈΠ²Π½ΠΎ ΠΈΡΡΠ»Π΅Π΄ΡƒΡŽΡ‚ΡΡ ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½Ρ‹Π΅ Π±ΠΈΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€Ρ‹ для диагностики Π±ΠΎΠ»Π΅Π·Π½Π΅ΠΉ Ρ‚ΠΊΠ°Π½Π΅ΠΉ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π°. Π˜ΡΡ‚ΠΎΡ‡Π½ΠΈΠΊΠΎΠΌ Π±ΠΈΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΎΠ² Π² ΠΏΠ΅Ρ€Π²ΡƒΡŽ ΠΎΡ‡Π΅Ρ€Π΅Π΄ΡŒ являСтся дСснСвая ΠΆΠΈΠ΄ΠΊΠΎΡΡ‚ΡŒ ΠΈ слюна, ΠΊΠ°ΠΊ Ρ‚Π°ΠΊΠΈΠ΅, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ нСпосрСдствСнно ΠΊΠΎΠ½Ρ‚Π°ΠΊΡ‚ΠΈΡ€ΡƒΡŽΡ‚ с ΠΏΠΎΡ€Π°ΠΆΠ΅Π½Π½Ρ‹ΠΌΠΈ тканями. Учитывая сказанноС, цСлСсообразно ΠΏΡ€ΠΎΠ°Π½Π°Π»ΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Ρ‚ΡŒ Π»ΠΈΡ‚Π΅Ρ€Π°Ρ‚ΡƒΡ€Π½Ρ‹Π΅ Π΄Π°Π½Π½Ρ‹Π΅ ΠΏΠΎ Π±ΠΈΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€Π°ΠΌ дСснСвой Тидкости ΠΈ ΡΠ»ΡŽΠ½Ρ‹, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΡŽΡ‚ для диагностики Π±ΠΎΠ»Π΅Π·Π½Π΅ΠΉ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π° ΠΈ возмоТности Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Ρ‚ΡŒ простыС Π² ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠΈ тСст-ΠΌΠ΅Ρ‚ΠΎΠ΄Ρ‹ для Ρ€Π°Π½Π½Π΅ΠΉ диагностики. ЦСль исслСдования – ΠΏΡ€ΠΎΠ°Π½Π°Π»ΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Ρ‚ΡŒ Π»ΠΈΡ‚Π΅Ρ€Π°Ρ‚ΡƒΡ€Π½Ρ‹Π΅ Π΄Π°Π½Π½Ρ‹Π΅ ΠΏΠΎ ΠΎΡ†Π΅Π½ΠΊΠ΅ пСрспСктивы примСнСния Π±ΠΈΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΎΠ² Π² стоматологичСской ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΠ΅, Π² частности Π² диагностикС ΠΏΠ°Ρ‚ΠΎΠ»ΠΎΠ³ΠΈΠΈ Ρ‚ΠΊΠ°Π½Π΅ΠΉ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π° вмСстС с ΠΏΠ΅Ρ€ΠΈΠΈΠΌΠΏΠ»Π°Π½Ρ‚Π½ΠΎΠΉ ΠΏΠ°Ρ‚ΠΎΠ»ΠΎΠ³ΠΈΠ΅ΠΉ. ΠœΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»Ρ‹ ΠΈ ΠΌΠ΅Ρ‚ΠΎΠ΄Ρ‹. Π’ исслСдовании ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½Ρ‹ библиосСматичСский ΠΈ аналитичСский ΠΌΠ΅Ρ‚ΠΎΠ΄Ρ‹. Π Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ исслСдований ΠΈ ΠΈΡ… обсуТдСниС. Π’ ΡΡ‚Π°Ρ‚ΡŒΠ΅ ΠΏΡ€ΠΎΠ°Π½Π°Π»ΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Π½Ρ‹ ΠΈ ΠΎΠ±Ρ€Π°Π±ΠΎΡ‚Π°Π½Ρ‹ источники Π½Π°ΡƒΡ‡Π½ΠΎ-мСдицинской ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΠΈ, ΠΊΠ°ΡΠ°ΡŽΡ‰ΠΈΠ΅ΡΡ примСнСния Π±ΠΈΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΎΠ² Π² диагностикС Π±ΠΎΠ»Π΅Π·Π½Π΅ΠΉ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π°. Π’Ρ‹Π²ΠΎΠ΄Ρ‹. НСсмотря Π½Π° Ρ‚ΠΎ, Ρ‡Ρ‚ΠΎ Π² диагностикС Ρ€ΠΎΡ‚ΠΎΠ²ΠΎΠΉ Тидкости имССтся Π·Π½Π°Ρ‡ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠ΅ количСство ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½Ρ‹Ρ… Π±ΠΈΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΎΠ², ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½Π½Ρ‹Π΅ Π½Π° сСгодняшний дСнь исслСдования оказались нСдостаточными для прСдоставлСния клиничСски достовСрной ΠΈ ΠΏΠΎΠ»Π΅Π·Π½ΠΎΠΉ ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΠΈ для ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΠΎΠ² с Ρ‚ΠΎΡ‡ΠΊΠΈ зрСния Π±ΠΎΠ»Π΅Π΅ Ρ‚ΠΎΡ‡Π½ΠΎΠΉ диагностики ΠΈ планирования лСчСния.Π₯Ρ€ΠΎΠ½Ρ–Ρ‡Π½ΠΈΠΉ ΠΏΠ΅Ρ€Π΅Π±Ρ–Π³ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚ΠΈΡ‚Ρƒ Ρ‚Π° Π³Ρ–Π½Π³Ρ–Π²Ρ–Ρ‚Ρƒ Π²Ρ€Π°ΠΆΠ°Ρ” Π΄ΠΎ 80 % дорослого насСлСння, ΡΡ‚Π°ΡŽΡ‡ΠΈ ΠΎΠ΄Π½ΠΈΠΌ Ρ–Π· Π½Π°ΠΉΠΏΠΎΡˆΠΈΡ€Π΅Π½Ρ–ΡˆΠΈΡ… сСрСд Ρ…Π²ΠΎΡ€ΠΎΠ± Π»ΡŽΠ΄ΡΡ‚Π²Π°. Π—Π°Ρ…Π²ΠΎΡ€ΡŽΠ²Π°Π½Π½Ρ Ρ–Π½Ρ–Ρ†Ρ–ΡŽΡ”Ρ‚ΡŒΡΡ накопичСнням Π±Π°ΠΊΡ‚Π΅Ρ€Ρ–ΠΉ Π²Π·Π΄ΠΎΠ²ΠΆ ясСнного ΠΊΡ€Π°ΡŽ Ρ– Π² просторі ΠΌΡ–ΠΆ ясСнними Ρ‚ΠΊΠ°Π½ΠΈΠ½Π°ΠΌΠΈ Ρ‚Π° Π·ΡƒΠ±Π°ΠΌΠΈ. Π’Ρ–Π΄ΡΡƒΡ‚Π½Ρ–ΡΡ‚ΡŒ ΠΊΠ»Ρ–Π½Ρ–ΠΊΠΈ гострого болю ΠΏΡ€ΠΈ Π·Π°Ρ…Π²ΠΎΡ€ΡŽΠ²Π°Π½Π½ΡΡ… ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π° Ρ” ΠΎΠ΄Π½Ρ–Ρ”ΡŽ Π· основних ΠΏΡ€ΠΈΡ‡ΠΈΠ½ низького рівня Π·Π²Π΅Ρ€Π½Π΅Π½ΡŒ ΠΏΠ°Ρ†Ρ–Ρ”Π½Ρ‚Ρ–Π² Π·Π° ΡΡ‚ΠΎΠΌΠ°Ρ‚ΠΎΠ»ΠΎΠ³Ρ–Ρ‡Π½ΠΎΡŽ допомогою. Діагностику Π·Π°Ρ…Π²ΠΎΡ€ΡŽΠ²Π°Π½ΡŒ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π°, як ΠΏΡ€Π°Π²ΠΈΠ»ΠΎ, ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΡ‚ΡŒ Π»Ρ–ΠΊΠ°Ρ€-стоматолог. Π’ΠΎΠ½Π° Π²ΠΊΠ»ΡŽΡ‡Π°Ρ” Π²Ρ–Π·ΡƒΠ°Π»ΡŒΠ½ΠΈΠΉ огляд Ρ‚ΠΊΠ°Π½ΠΈΠ½ ясСн Ρ‚Π° ряд Ρ–Π½ΡˆΠΈΡ… ΠΏΡ€ΠΎΡ‚ΠΎΠΊΠΎΠ»ΡŒΠ½ΠΈΡ… ΠΏΡ€ΠΎΡ†Π΅Π΄ΡƒΡ€, Ρƒ Ρ‚ΠΎΠΌΡƒ числі Π΄ΠΎΠ΄ΠΎΡ‚ΠΊΠΎΠ²ΠΈΡ… ΠΌΠ΅Ρ‚ΠΎΠ΄Ρ–Π² діагностики – ΠΊΠ»Ρ–Π½Ρ–Ρ‡Π½Ρƒ ΠΎΡ†Ρ–Π½ΠΊΡƒ Ρ€Π΅Π½Ρ‚Π΅Π½ΠΎΠ³Ρ€Π°ΠΌΠΈ. Водночас, Π·Π²ΠΈΡ‡Π°ΠΉΠ½Ρ– ΠΊΠ»Ρ–Π½Ρ–Ρ‡Π½Ρ– Ρ‚Π° Ρ€Π΅Π½Ρ‚Π³Π΅Π½ΠΎΠ³Ρ€Π°Ρ„Ρ–Ρ‡Π½Ρ– ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈ діагностики ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π° Π·Π΄Π°Ρ‚Π½Ρ– лишС Π΄ΠΎ рСтроспСктивного Π΄Ρ–Π°Π³Π½ΠΎΠ·Ρƒ, Π²ΠΎΠ½ΠΈ Π½Π΅ ΠΌΠΎΠΆΡƒΡ‚ΡŒ виявити Π°Π±ΠΎ ΠΏΠ΅Ρ€Π΅Π΄Π±Π°Ρ‡ΠΈΡ‚ΠΈ Π°ΠΊΡ‚ΠΈΠ²Π½Ρ–ΡΡ‚ΡŒ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚ΠΈΡ‚Ρƒ. Π’ΠΎΠΌΡƒ Π² останні Ρ€ΠΎΠΊΠΈ Π°ΠΊΡ‚ΠΈΠ²Π½ΠΎ Π΄ΠΎΡΠ»Ρ–Π΄ΠΆΡƒΡŽΡ‚ΡŒ ΠΏΠΎΡ‚Π΅Π½Ρ†Ρ–ΠΉΠ½Ρ– Π±Ρ–ΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΈ для діагностування Ρ…Π²ΠΎΡ€ΠΎΠ± Ρ‚ΠΊΠ°Π½ΠΈΠ½ ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π°. Π”ΠΆΠ΅Ρ€Π΅Π»ΠΎΠΌ Π±Ρ–ΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€Ρ–Π² ΠΏΠ΅Ρ€Ρˆ Π·Π° всС Ρ” ясСнна Ρ€Ρ–Π΄ΠΈΠ½Π° Ρ‚Π° слина, як Ρ‚Π°ΠΊΡ–, Ρ‰ΠΎ Π±Π΅Π·ΠΏΠΎΡΠ΅Ρ€Π΅Π΄Π½ΡŒΠΎ ΠΊΠΎΠ½Ρ‚Π°ΠΊΡ‚ΡƒΡŽΡ‚ΡŒ Π· ΡƒΡ€Π°ΠΆΠ΅Π½ΠΈΠΌΠΈ Ρ‚ΠΊΠ°Π½ΠΈΠ½Π°ΠΌΠΈ. Π’Ρ€Π°Ρ…ΠΎΠ²ΡƒΡŽΡ‡ΠΈ сказанС, Π΄ΠΎΡ†Ρ–Π»ΡŒΠ½ΠΎ ΠΏΡ€ΠΎΠ°Π½Π°Π»Ρ–Π·ΡƒΠ²Π°Ρ‚ΠΈ Π»Ρ–Ρ‚Π΅Ρ€Π°Ρ‚ΡƒΡ€Π½Ρ– Π΄Π°Π½Ρ– Ρ‰ΠΎΠ΄ΠΎ Π±Ρ–ΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€Ρ–Π² ясСнної Ρ€Ρ–Π΄ΠΈΠ½ΠΈ Ρ‚Π° слини, які Π²ΠΈΠΊΠΎΡ€ΠΈΡΡ‚ΠΎΠ²ΡƒΡŽΡ‚ΡŒ для діагностики Ρ…Π²ΠΎΡ€ΠΎΠ± ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π° Ρ‚Π° моТливості Ρ€ΠΎΠ·Ρ€ΠΎΠ±ΠΈΡ‚ΠΈ прості Ρƒ застосуванні тСст-ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈ для Ρ€Π°Π½Π½ΡŒΠΎΡ— діагностики. ΠœΠ΅Ρ‚Π° дослідТСння – ΠΏΡ€ΠΎΠ°Π½Π°Π»Ρ–Π·ΡƒΠ²Π°Ρ‚ΠΈ Π»Ρ–Ρ‚Π΅Ρ€Π°Ρ‚ΡƒΡ€Π½Ρ– Π΄Π°Π½Ρ– Ρ‰ΠΎΠ΄ΠΎ ΠΎΡ†Ρ–Π½ΠΊΠΈ пСрспСктиви застосування Π±Ρ–ΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€Ρ–Π² Ρƒ стоматологічній ΠΏΡ€Π°ΠΊΡ‚ΠΈΡ†Ρ–, Π·ΠΎΠΊΡ€Π΅ΠΌΠ° Π² діагностиці ΠΏΠ°Ρ‚ΠΎΠ»ΠΎΠ³Ρ–Ρ— Ρ‚ΠΊΠ°Π½ΠΈΠ½ ΠΏΠ°Ρ€Π°Π΄ΠΎΠ½Ρ‚Π° Ρ€Π°Π·ΠΎΠΌ Ρ–Π· ΠΏΠ΅Ρ€Ρ–Ρ–ΠΌΠΏΠ»Π°Π½Ρ‚Π½ΠΎΡŽ ΠΏΠ°Ρ‚ΠΎΠ»ΠΎΠ³Ρ–Ρ”ΡŽ. ΠœΠ°Ρ‚Π΅Ρ€Ρ–Π°Π»ΠΈ Ρ– ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈ. Π£ дослідТСнні застосовано бібліосСматичний Ρ‚Π° Π°Π½Π°Π»Ρ–Ρ‚ΠΈΡ‡Π½ΠΈΠΉ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈ. Π Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΈ Π΄ΠΎΡΠ»Ρ–Π΄ΠΆΠ΅Π½ΡŒ Ρ‚Π° Ρ—Ρ… обговорСння. Π£ статті ΠΏΡ€ΠΎΠ°Π½Π°Π»Ρ–Π·ΠΎΠ²Π°Π½ΠΎ Ρ‚Π° ΠΎΠΏΡ€Π°Ρ†ΡŒΠΎΠ²Π°Π½ΠΎ Π΄ΠΆΠ΅Ρ€Π΅Π»Π° Π½Π°ΡƒΠΊΠΎΠ²ΠΎ-ΠΌΠ΅Π΄ΠΈΡ‡Π½ΠΎΡ— Ρ–Π½Ρ„ΠΎΡ€ΠΌΠ°Ρ†Ρ–Ρ—, Ρ‰ΠΎ ΡΡ‚ΠΎΡΡƒΡŽΡ‚ΡŒΡΡ застосування Π±Ρ–ΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€Ρ–Π² Ρƒ діагностиці Ρ…Π²ΠΎΡ€ΠΎΠ± ΠΏΠ°Ρ€ΠΎΠ΄ΠΎΠ½Ρ‚Π°. Висновки. ΠΠ΅Π·Π²Π°ΠΆΠ°ΡŽΡ‡ΠΈ Π½Π° Ρ‚Π΅, Ρ‰ΠΎ Π² діагностиці Ρ€ΠΎΠ³ΠΎΠ²ΠΎΡ— Ρ€Ρ–Π΄ΠΈΠ½ΠΈ наявна Π·Π½Π°Ρ‡Π½Π° ΠΊΡ–Π»ΡŒΠΊΡ–ΡΡ‚ΡŒ ΠΏΠΎΡ‚Π΅Π½Ρ†Ρ–ΠΉΠ½ΠΈΡ… Π±Ρ–ΠΎΠΌΠ°Ρ€ΠΊΠ΅Ρ€Ρ–Π², ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½Ρ– Π½Π° ΡΡŒΠΎΠ³ΠΎΠ΄Π½Ρ– дослідТСння виявилися нСдостатніми Ρ‰ΠΎΠ΄ΠΎ надання ΠΊΠ»Ρ–Π½Ρ–Ρ‡Π½ΠΎ достовірної Ρ‚Π° корисної Ρ–Π½Ρ„ΠΎΡ€ΠΌΠ°Ρ†Ρ–Ρ— для ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΡ–Π² Π· Ρ‚ΠΎΡ‡ΠΊΠΈ Π·ΠΎΡ€Ρƒ Π±Ρ–Π»ΡŒΡˆ Ρ‚ΠΎΡ‡Π½ΠΎΡ— діагностики Ρ‚Π° планування лікування

    Assessment of the muscle state indicators by improved myotonometer

    No full text
    Авторами статті удосконалСно ΠΉ Π°ΠΏΡ€ΠΎΠ±ΠΎΠ²Π°Π½ΠΎ Π½ΠΎΠ²Ρƒ ΠΊΠΎΠ½ΡΡ‚Ρ€ΡƒΠΊΡ†Ρ–ΡŽ стоматологічного ΠΌΡ–ΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€Π°. УдосконалСна конструкція ΠΌΡ–ΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€Π° ΡΠΊΠ»Π°Π΄Π°Ρ”Ρ‚ΡŒΡΡ Π· корпусу, ΡˆΡ‚ΠΎΠΊΡƒ, ΠΏΡ€ΡƒΠΆΠΈΠ½ΠΈ, Ρ‚Π°ΠΊΡ‚ΠΈΠ»ΡŒΠ½ΠΎΠ³ΠΎ Ρ‰ΡƒΠΏΡƒ Ρ‚Π° WIFI Π΄Π°Ρ‚Ρ‡ΠΈΠΊΠ° пСрСміщСння. Π’Π°ΠΊΡ‚ΠΈΠ»ΡŒΠ½ΠΈΠΉ Ρ‰ΡƒΠΏ з’єднаний Π· WIFI ΠΏΠ΅Ρ€Π΅Π΄Π°Π²Π°Ρ‡Π΅ΠΌ Ρ€ΡƒΡ…Ρƒ, Ρ‚Π° ΠΌΠ°Ρ” ΠΌΠΎΠΆΠ»ΠΈΠ²Ρ–ΡΡ‚ΡŒ пСрСміщСння всСрСдині корпусу Π·Π° допомогою Bluetooth-зв’язку, ΠΏΡ€ΠΈΠ²ΠΎΠ΄ΠΈΡ‚ΡŒΡΡ Π² Π΄Ρ–ΡŽ ΠΏΡ€ΠΈ Π·Π°Π½ΡƒΡ€Π΅Π½Π½Ρ– Π² розслаблСні Ρ‚ΠΊΠ°Π½ΠΈΠ½ΠΈ, Π° Ρ‚Π°ΠΊΠΎΠΆ Π² ΠΌΠΎΠΌΠ΅Π½Ρ‚ Π½Π°ΠΏΡ€ΡƒΠ³ΠΈ м’язів. Π—Π°ΠΏΡ€ΠΎΠΏΠΎΠ½ΠΎΠ²Π°Π½ΠΈΠΉ ΠΌΡ–ΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€, Π·Π° Ρ€Π°Ρ…ΡƒΠ½ΠΎΠΊ ввСдСння Π² ΠΉΠΎΠ³ΠΎ ΠΊΠΎΠ½ΡΡ‚Ρ€ΡƒΠΊΡ†Ρ–ΡŽ Π΄ΠΎΠ΄Π°Ρ‚ΠΊΠΎΠ²ΠΈΡ… Π΅Π»Π΅ΠΌΠ΅Π½Ρ‚Ρ–Π² Ρ‚Π° ΠΏΡ€ΠΈΠ½Ρ†ΠΈΠΏΡƒ Π΄Ρ–Ρ—, Π·Π°Π±Π΅Π·ΠΏΠ΅Ρ‡ΡƒΡ” ΠΏΠΎΠ»Ρ–ΠΏΡˆΠ΅Π½Π½Ρ зручності ΠΏΡ€ΠΈ ΠΉΠΎΠ³ΠΎ використанні для визначСння ΠΏΠΎΠΊΠ°Π·Π½ΠΈΠΊΡ–Π² стану м’язів Π² Π΄ΠΈΠ½Π°ΠΌΡ–Ρ†Ρ– Ρ‚Π° ΠΏΠ΅Ρ€Π΅Ρ…Ρ–Π΄ Π· розряду ΠΌΠ΅Ρ…Π°Π½Ρ–Ρ‡Π½ΠΈΡ… Π΄Π°Ρ‚Ρ‡ΠΈΠΊΡ–Π² Π΄ΠΎ розряду ΡƒΠ»ΡŒΡ‚Ρ€Π°ΡΡƒΡ‡Π°ΡΠ½ΠΈΡ… ΠΏΠΎΡ€Ρ‚Π°Ρ‚ΠΈΠ²Π½ΠΈΡ… пристроїв, Π·Π΄Π°Ρ‚Π½ΠΈΡ… Π· високою Ρ‚ΠΎΡ‡Π½Ρ–ΡΡ‚ΡŽ Π·Π±ΠΈΡ€Π°Ρ‚ΠΈ, Π½Π°ΠΊΠΎΠΏΠΈΡ‡ΡƒΠ²Π°Ρ‚ΠΈ Ρ‚Π° Π°Π½Π°Π»Ρ–Π·ΡƒΠ²Π°Ρ‚ΠΈ ΠΎΠ΄Π΅Ρ€ΠΆΠ°Π½Ρƒ Ρ–Π½Ρ„ΠΎΡ€ΠΌΠ°Ρ†Ρ–ΡŽ, Ρ‰ΠΎ Π²Ρ–Π΄ΠΏΠΎΠ²Ρ–Π΄Π°Ρ” поставлСній Π·Π°Π΄Π°Ρ‡Ρ–.; Авторами ΡΡ‚Π°Ρ‚ΡŒΠΈ ΡƒΡΠΎΠ²Π΅Ρ€ΡˆΠ΅Π½ΡΡ‚Π²ΠΎΠ²Π°Π½Π° ΠΈ Π°ΠΏΡ€ΠΎΠ±ΠΈΡ€ΠΎΠ²Π°Π½Π° новая конструкция стоматологичСского ΠΌΠΈΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€Π°. Π£ΡΠΎΠ²Π΅Ρ€ΡˆΠ΅Π½ΡΡ‚Π²ΠΎΠ²Π°Π½Π½Π°Ρ конструкция ΠΌΠΈΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€Π° состоит ΠΈΠ· корпуса, ΡˆΡ‚ΠΎΠΊΠ°, ΠΏΡ€ΡƒΠΆΠΈΠ½Ρ‹, Ρ‚Π°ΠΊΡ‚ΠΈΠ»ΡŒΠ½ΠΎΠ³ΠΎ Ρ‰ΡƒΠΏΠ° ΠΈ WIFI Π΄Π°Ρ‚Ρ‡ΠΈΠΊΠ° пСрСмСщСния. Π’Π°ΠΊΡ‚ΠΈΠ»ΡŒΠ½Ρ‹ΠΉ Ρ‰ΡƒΠΏ соСдинСн с WIFI ΠΏΠ΅Ρ€Π΅Π΄Π°Ρ‚Ρ‡ΠΈΠΊΠΎΠΌ двиТСния, ΠΈ ΠΈΠΌΠ΅Π΅Ρ‚ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ пСрСмСщСния Π²Π½ΡƒΡ‚Ρ€ΠΈ корпуса с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ Bluetooth-связи, приводится Π² дСйствиС ΠΏΡ€ΠΈ ΠΏΠΎΠ³Ρ€ΡƒΠΆΠ΅Π½ΠΈΠΈ Π² расслаблСнныС Ρ‚ΠΊΠ°Π½ΠΈ, Π° Ρ‚Π°ΠΊΠΆΠ΅ Π² ΠΌΠΎΠΌΠ΅Π½Ρ‚ напряТСния ΠΌΡ‹ΡˆΡ†. ΠŸΡ€Π΅Π΄Π»ΠΎΠΆΠ΅Π½Π½Ρ‹ΠΉ ΠΌΠΈΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€, Π·Π° счСт ввСдСния Π² Π΅Π³ΠΎ ΠΊΠΎΠ½ΡΡ‚Ρ€ΡƒΠΊΡ†ΠΈΡŽ Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ… элСмСнтов ΠΈ ΠΏΡ€ΠΈΠ½Ρ†ΠΈΠΏΠ° дСйствия, обСспСчиваСт ΡƒΠ»ΡƒΡ‡ΡˆΠ΅Π½ΠΈΠ΅ удобства ΠΏΡ€ΠΈ Π΅Π³ΠΎ использовании для опрСдСлСния ΠΏΠΎΠΊΠ°Π·Π°Ρ‚Π΅Π»Π΅ΠΉ состояния ΠΌΡ‹ΡˆΡ† Π² Π΄ΠΈΠ½Π°ΠΌΠΈΠΊΠ΅ ΠΈ ΠΏΠ΅Ρ€Π΅Ρ…ΠΎΠ΄ ΠΈΠ· разряда мСханичСских Π΄Π°Ρ‚Ρ‡ΠΈΠΊΠΎΠ² ΠΊ разряду ΡƒΠ»ΡŒΡ‚Ρ€Π°ΡΠΎΠ²Ρ€Π΅ΠΌΠ΅Π½Π½Ρ‹Ρ… ΠΏΠΎΡ€Ρ‚Π°Ρ‚ΠΈΠ²Π½Ρ‹Ρ… устройств, способных с высокой Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒΡŽ ΡΠΎΠ±ΠΈΡ€Π°Ρ‚ΡŒ, Π½Π°ΠΊΠ°ΠΏΠ»ΠΈΠ²Π°Ρ‚ΡŒ ΠΈ Π°Π½Π°Π»ΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Ρ‚ΡŒ ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π½ΡƒΡŽ ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΡŽ, ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‰ΡƒΡŽ поставлСнной Π·Π°Π΄Π°Ρ‡Π΅.; The new design of dental myotonometer has been improved and tested by the authors. Improved design of myotonometer consists of device body (housing), stem, spring, touch probe and Wi-Fi displacement sensor. Touch probe is connected to Wi-Fi movement transmitter and is moved inside the device by Bluetooth connection, it is activated while immersing into the relaxed tissue and also at the moment of muscles tension. The task on myotonometer improvement has been set by the authors. It was achieved by introducing of additional elements into myotonometer structure, changing location of existing elements and operating principle of the device that would improve the convenience when using it for assessment of the muscles condition in dynamics and transition from the category of mechanical sensors into the category of ultra portable devices that can collect, accumulate and analyze information to a high precision. The task was solved by creation of the myotonometer, including the device body, stem, touch probe, which, according to the utility model is characterized by its portability and has wireless connection to computer, in addition Wi-Fi movement transmitter is introduced to device, while touch probe is connected with Wi-Fi movement transmitter and is moved inside device body by Bluetooth connection. The proposed myotonometer consists of device body (housing) (1), stem (2), spring (3), touch probe (4) and Wi-Fi displacement sensor (5). Touch probe is connected to Wi-Fi movement transmitter and can be moved inside the device body using Bluetooth connection, it is activated while immersing in the relaxed tissue and at the moment of muscles tension. The registration of mouse cursor movement on the computer screen is being carried out on the recording scale of cursor movement in Word text document. After a series of test measurements on the film surface, it should be scanned and analized by FPD – 8010E program, that enables to compare the amplitude of cursor movement along the scale with the certain touch probe force. The principle of myotonometer operation is based on displacement and transmission of the amplitude of this displacement using computer cursor on a scale of movement, that enables to change the category of mechanical sensors into the category of ultra portable devices that can collect, accumulate and analyze obtained information to a high precision. The proposed myotonometer provides improved convenience while using it for the assessment of muscles condition in dynamics, by introduction of additional elements and principles of functioning to its structure and transition from the category of mechanical sensors to the category of ultra portable devices that can accurately collect, accumulate and analyze information relevant to the task

    Assessment of the muscle state indicators by improved myotonometer

    No full text
    Авторами статті удосконалСно ΠΉ Π°ΠΏΡ€ΠΎΠ±ΠΎΠ²Π°Π½ΠΎ Π½ΠΎΠ²Ρƒ ΠΊΠΎΠ½ΡΡ‚Ρ€ΡƒΠΊΡ†Ρ–ΡŽ стоматологічного ΠΌΡ–ΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€Π°. УдосконалСна конструкція ΠΌΡ–ΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€Π° ΡΠΊΠ»Π°Π΄Π°Ρ”Ρ‚ΡŒΡΡ Π· корпусу, ΡˆΡ‚ΠΎΠΊΡƒ, ΠΏΡ€ΡƒΠΆΠΈΠ½ΠΈ, Ρ‚Π°ΠΊΡ‚ΠΈΠ»ΡŒΠ½ΠΎΠ³ΠΎ Ρ‰ΡƒΠΏΡƒ Ρ‚Π° WIFI Π΄Π°Ρ‚Ρ‡ΠΈΠΊΠ° пСрСміщСння. Π’Π°ΠΊΡ‚ΠΈΠ»ΡŒΠ½ΠΈΠΉ Ρ‰ΡƒΠΏ з’єднаний Π· WIFI ΠΏΠ΅Ρ€Π΅Π΄Π°Π²Π°Ρ‡Π΅ΠΌ Ρ€ΡƒΡ…Ρƒ, Ρ‚Π° ΠΌΠ°Ρ” ΠΌΠΎΠΆΠ»ΠΈΠ²Ρ–ΡΡ‚ΡŒ пСрСміщСння всСрСдині корпусу Π·Π° допомогою Bluetooth-зв’язку, ΠΏΡ€ΠΈΠ²ΠΎΠ΄ΠΈΡ‚ΡŒΡΡ Π² Π΄Ρ–ΡŽ ΠΏΡ€ΠΈ Π·Π°Π½ΡƒΡ€Π΅Π½Π½Ρ– Π² розслаблСні Ρ‚ΠΊΠ°Π½ΠΈΠ½ΠΈ, Π° Ρ‚Π°ΠΊΠΎΠΆ Π² ΠΌΠΎΠΌΠ΅Π½Ρ‚ Π½Π°ΠΏΡ€ΡƒΠ³ΠΈ м’язів. Π—Π°ΠΏΡ€ΠΎΠΏΠΎΠ½ΠΎΠ²Π°Π½ΠΈΠΉ ΠΌΡ–ΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€, Π·Π° Ρ€Π°Ρ…ΡƒΠ½ΠΎΠΊ ввСдСння Π² ΠΉΠΎΠ³ΠΎ ΠΊΠΎΠ½ΡΡ‚Ρ€ΡƒΠΊΡ†Ρ–ΡŽ Π΄ΠΎΠ΄Π°Ρ‚ΠΊΠΎΠ²ΠΈΡ… Π΅Π»Π΅ΠΌΠ΅Π½Ρ‚Ρ–Π² Ρ‚Π° ΠΏΡ€ΠΈΠ½Ρ†ΠΈΠΏΡƒ Π΄Ρ–Ρ—, Π·Π°Π±Π΅Π·ΠΏΠ΅Ρ‡ΡƒΡ” ΠΏΠΎΠ»Ρ–ΠΏΡˆΠ΅Π½Π½Ρ зручності ΠΏΡ€ΠΈ ΠΉΠΎΠ³ΠΎ використанні для визначСння ΠΏΠΎΠΊΠ°Π·Π½ΠΈΠΊΡ–Π² стану м’язів Π² Π΄ΠΈΠ½Π°ΠΌΡ–Ρ†Ρ– Ρ‚Π° ΠΏΠ΅Ρ€Π΅Ρ…Ρ–Π΄ Π· розряду ΠΌΠ΅Ρ…Π°Π½Ρ–Ρ‡Π½ΠΈΡ… Π΄Π°Ρ‚Ρ‡ΠΈΠΊΡ–Π² Π΄ΠΎ розряду ΡƒΠ»ΡŒΡ‚Ρ€Π°ΡΡƒΡ‡Π°ΡΠ½ΠΈΡ… ΠΏΠΎΡ€Ρ‚Π°Ρ‚ΠΈΠ²Π½ΠΈΡ… пристроїв, Π·Π΄Π°Ρ‚Π½ΠΈΡ… Π· високою Ρ‚ΠΎΡ‡Π½Ρ–ΡΡ‚ΡŽ Π·Π±ΠΈΡ€Π°Ρ‚ΠΈ, Π½Π°ΠΊΠΎΠΏΠΈΡ‡ΡƒΠ²Π°Ρ‚ΠΈ Ρ‚Π° Π°Π½Π°Π»Ρ–Π·ΡƒΠ²Π°Ρ‚ΠΈ ΠΎΠ΄Π΅Ρ€ΠΆΠ°Π½Ρƒ Ρ–Π½Ρ„ΠΎΡ€ΠΌΠ°Ρ†Ρ–ΡŽ, Ρ‰ΠΎ Π²Ρ–Π΄ΠΏΠΎΠ²Ρ–Π΄Π°Ρ” поставлСній Π·Π°Π΄Π°Ρ‡Ρ–; Авторами ΡΡ‚Π°Ρ‚ΡŒΠΈ ΡƒΡΠΎΠ²Π΅Ρ€ΡˆΠ΅Π½ΡΡ‚Π²ΠΎΠ²Π°Π½Π° ΠΈ Π°ΠΏΡ€ΠΎΠ±ΠΈΡ€ΠΎΠ²Π°Π½Π° новая конструкция стоматологичСского ΠΌΠΈΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€Π°. Π£ΡΠΎΠ²Π΅Ρ€ΡˆΠ΅Π½ΡΡ‚Π²ΠΎΠ²Π°Π½Π½Π°Ρ конструкция ΠΌΠΈΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€Π° состоит ΠΈΠ· корпуса, ΡˆΡ‚ΠΎΠΊΠ°, ΠΏΡ€ΡƒΠΆΠΈΠ½Ρ‹, Ρ‚Π°ΠΊΡ‚ΠΈΠ»ΡŒΠ½ΠΎΠ³ΠΎ Ρ‰ΡƒΠΏΠ° ΠΈ WIFI Π΄Π°Ρ‚Ρ‡ΠΈΠΊΠ° пСрСмСщСния. Π’Π°ΠΊΡ‚ΠΈΠ»ΡŒΠ½Ρ‹ΠΉ Ρ‰ΡƒΠΏ соСдинСн с WIFI ΠΏΠ΅Ρ€Π΅Π΄Π°Ρ‚Ρ‡ΠΈΠΊΠΎΠΌ двиТСния, ΠΈ ΠΈΠΌΠ΅Π΅Ρ‚ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ пСрСмСщСния Π²Π½ΡƒΡ‚Ρ€ΠΈ корпуса с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ Bluetooth-связи, приводится Π² дСйствиС ΠΏΡ€ΠΈ ΠΏΠΎΠ³Ρ€ΡƒΠΆΠ΅Π½ΠΈΠΈ Π² расслаблСнныС Ρ‚ΠΊΠ°Π½ΠΈ, Π° Ρ‚Π°ΠΊΠΆΠ΅ Π² ΠΌΠΎΠΌΠ΅Π½Ρ‚ напряТСния ΠΌΡ‹ΡˆΡ†. ΠŸΡ€Π΅Π΄Π»ΠΎΠΆΠ΅Π½Π½Ρ‹ΠΉ ΠΌΠΈΠΎΡ‚ΠΎΠ½ΠΎΠΌΠ΅Ρ‚Ρ€, Π·Π° счСт ввСдСния Π² Π΅Π³ΠΎ ΠΊΠΎΠ½ΡΡ‚Ρ€ΡƒΠΊΡ†ΠΈΡŽ Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ… элСмСнтов ΠΈ ΠΏΡ€ΠΈΠ½Ρ†ΠΈΠΏΠ° дСйствия, обСспСчиваСт ΡƒΠ»ΡƒΡ‡ΡˆΠ΅Π½ΠΈΠ΅ удобства ΠΏΡ€ΠΈ Π΅Π³ΠΎ использовании для опрСдСлСния ΠΏΠΎΠΊΠ°Π·Π°Ρ‚Π΅Π»Π΅ΠΉ состояния ΠΌΡ‹ΡˆΡ† Π² Π΄ΠΈΠ½Π°ΠΌΠΈΠΊΠ΅ ΠΈ ΠΏΠ΅Ρ€Π΅Ρ…ΠΎΠ΄ ΠΈΠ· разряда мСханичСских Π΄Π°Ρ‚Ρ‡ΠΈΠΊΠΎΠ² ΠΊ разряду ΡƒΠ»ΡŒΡ‚Ρ€Π°ΡΠΎΠ²Ρ€Π΅ΠΌΠ΅Π½Π½Ρ‹Ρ… ΠΏΠΎΡ€Ρ‚Π°Ρ‚ΠΈΠ²Π½Ρ‹Ρ… устройств, способных с высокой Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒΡŽ ΡΠΎΠ±ΠΈΡ€Π°Ρ‚ΡŒ, Π½Π°ΠΊΠ°ΠΏΠ»ΠΈΠ²Π°Ρ‚ΡŒ ΠΈ Π°Π½Π°Π»ΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Ρ‚ΡŒ ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π½ΡƒΡŽ ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΡŽ, ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‰ΡƒΡŽ поставлСнной Π·Π°Π΄Π°Ρ‡Π΅; The new design of dental myotonometer has been improved and tested by the authors. Improved design of myotonometer consists of device body (housing), stem, spring, touch probe and Wi-Fi displacement sensor. Touch probe is connected to Wi-Fi movement transmitter and is moved inside the device by Bluetooth connection, it is activated while immersing into the relaxed tissue and also at the moment of muscles tension. The task on myotonometer improvement has been set by the authors. It was achieved by introducing of additional elements into myotonometer structure, changing location of existing elements and operating principle of the device that would improve the convenience when using it for assessment of the muscles condition in dynamics and transition from the category of mechanical sensors into the category of ultra portable devices that can collect, accumulate and analyze information to a high precision. The task was solved by creation of the myotonometer, including the device body, stem, touch probe, which, according to the utility model is characterized by its portability and has wireless connection to computer, in addition Wi-Fi movement transmitter is introduced to device, while touch probe is connected with Wi-Fi movement transmitter and is moved inside device body by Bluetooth connection. The proposed myotonometer consists of device body (housing) (1), stem (2), spring (3), touch probe (4) and Wi-Fi displacement sensor (5). Touch probe is connected to Wi-Fi movement transmitter and can be moved inside the device body using Bluetooth connection, it is activated while immersing in the relaxed tissue and at the moment of muscles tension. The registration of mouse cursor movement on the computer screen is being carried out on the recording scale of cursor movement in Word text document. After a series of test measurements on the film surface, it should be scanned and analized by FPD – 8010E program, that enables to compare the amplitude of cursor movement along the scale with the certain touch probe force. The principle of myotonometer operation is based on displacement and transmission of the amplitude of this displacement using computer cursor on a scale of movement, that enables to change the category of mechanical sensors into the category of ultra portable devices that can collect, accumulate and analyze obtained information to a high precision. The proposed myotonometer provides improved convenience while using it for the assessment of muscles condition in dynamics, by introduction of additional elements and principles of functioning to its structure and transition from the category of mechanical sensors to the category of ultra portable devices that can accurately collect, accumulate and analyze information relevant to the task
    corecore