54 research outputs found

    Performance studies of the final prototype for the CASTOR forward calorimeter at the CMS experiment

    Get PDF
    We present performance results of the final prototype for the CASTOR quartz-tungsten sampling calorimeter, to be installed in the very forward region of the CMS experiment at the LHC. The energy linearity and resolution, the uniformity, as well as the spatial resolution of the prototype to electromagnetic and hadronic showers are studied with E=E= 10--200 GeV electrons, E=E= 20--350 GeV pions, and E=E= 50, 150 GeV muons in beam tests carried out at CERN/SPS in 2007

    Observation of weak neutral current neutrino production of J/ψJ/\psi

    Get PDF
    Observation of \jpsi production by neutrinos in the calorimeter of the CHORUS detector exposed to the CERN SPS wide-band \numu beam is reported. A spectrum-averaged cross-section σJ/ψ\sigma^{\mathrm{J/\psi}} = (6.3 ±\pm 3.0) ×10−41 cm2\times \mathrm{10^{-41}~cm^{2}} is obtained for 20 GeV ≀EΜ≀\leq E_{\nu} \leq 200 GeV. The data are compared with the theoretical model based on the QCD Z-gluon fusion mechanism

    The CHORUS neutrino oscillation search experiment

    Get PDF
    The CHORUS experiment has successfully finished run I (320~000 recorded \numu\ CC in 94/95) and performed half of run II (225~000 \numu\ CC in 96). The analysis chain was exercised on a small data sample for the muonic \tdecay\ search using for the first time fully automatic emulsion scanning. This pilot analysis, resulting in a limit \sintth \leq 3 \cdot 10^{-2}, confirms that the CHORUS proposal sensitivity (\sintth \leq 3 \cdot 10^{-4}) is within reach in two years

    Design, Performance, and Calibration of CMS Hadron-Barrel Calorimeter Wedges

    Get PDF
    Extensive measurements have been made with pions, electrons and muons on four production wedges of the Compact Muon Solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. Data were taken both with and without a prototype electromagnetic lead tungstate crystal calorimeter (EB) in front of the hadron calorimeter. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. These measurements set the absolute calibration of the HB prior to first pp collisions to approximately 4%

    Synchronization and Timing in CMS HCAL

    Get PDF
    The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile

    Design, Performance and Calibration of the CMS Forward Calorimeter Wedges

    Get PDF
    We report on the test beam results and calibration methods using charged particles of the CMS Forward Calorimeter (HF). The HF calorimeter covers a large pseudorapidity region (3\l |\eta| \le 5), and is essential for large number of physics channels with missing transverse energy. It is also expected to play a prominent role in the measurement of forward tagging jets in weak boson fusion channels. The HF calorimeter is based on steel absorber with embedded fused-silica-core optical fibers where Cherenkov radiation forms the basis of signal generation. Thus, the detector is essentially sensitive only to the electromagnetic shower core and is highly non-compensating (e/h \approx 5). This feature is also manifest in narrow and relatively short showers compared to similar calorimeters based on ionization. The choice of fused-silica optical fibers as active material is dictated by its exceptional radiation hardness. The electromagnetic energy resolution is dominated by photoelectron statistics and can be expressed in the customary form as a/\sqrt{E} + b. The stochastic term a is 198% and the constant term b is 9%. The hadronic energy resolution is largely determined by the fluctuations in the neutral pion production in showers, and when it is expressed as in the electromagnetic case, a = 280% and b = 11%

    Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    Get PDF
    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%

    Design, Performance, and Calibration of the CMS Hadron-Outer Calorimeter

    Get PDF
    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with an outer calorimeter to ensure high energy shower containment in the calorimeter. Fabrication, testing and calibration of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing \et measurements at LHC energies. The outer hadron calorimeter will also be used for the muon trigger in coincidence with other muon chambers in CMS

    New results from a search for v” â€ș v? and ve â€ș v? oscillation

    No full text
    A first analysis of the complete set of data collected by CHORUS in the years 1994-1997 is presented. The search for v? charged current events has been performed for both leptonic and hadronic decays of the ? lepton. No ? candidate has been found. A v” â€ș v? mixing is excluded down to sin22?”? = 6.8 × 10-4 for large ?m2 (90% C.L.). © 2001 Elsevier Science B.V.Grant Foundation: KRF-99-005-D00004 Brussels Instituut voor Milieubeheer Bundesministerium fĂŒr Bildung und Forschung CERN Israel Science Foundation: 328/94 Promotion and Mutual Aid Corporation for Private Schools of Japan Istituto Nazionale di Fisica Nucleare Foundation for Fundamental Research on Matter Korean Foundation for Cancer Research Walter Burke Institute for Theoretical PhysicsWe gratefully acknowledge the help and support of our numerous technical collaborators who contributed to the detector construction, operation, emulsion pouring, development and scanning. We thank the neutrino beam staff for their competent assistance in ensuring the excellent performance of the facility. The accumulation of a large data sample in this experiment has been made possible also thanks to the efforts of the crew operating the CERN PS and SPS. The general technical support from CERN EP (PPE, ECP) and IT (CN) divisions is warmly acknowledged. The experiment has been made possible by grants from: the Institut Interuniversitaire des Sciences NuclĂ©aires and the Interuniversitair Instituut voor Kernwetenschappen (Belgium), the Israel Science foundation (grant 328/94) and the Technion Vice President Fund for the Promotion of Research (Israel), CERN (Geneva, Switzerland), the German Bundesministerium fĂŒr Bildung und Forschung (Germany), the Institute of Theoretical and Experimental Physics (Moscow, Russia), the Istituto Nazionale di Fisica Nucleare (Italy), the Promotion and Mutual Aid Corporation for Private Schools of Japan and Japan Society for the Promotion of Science (Japan), the Korea Research Foundation Grant (KRF-99-005-D00004) (Republic of Korea), the Foundation for Fundamental Research on Matter FOM and the National Scientific Research Organization NWO (The Netherlands) and the Scientific and Technical Research Council of Turkey (Turkey). We gratefully acknowledge their support. Two of the authors, A. Arik and A.A. Mailov, wish to acknowledge their collaboration with S. Sultansoy
    • 

    corecore