4 research outputs found

    One-Year Outcomes after Surgical versus Transcatheter Aortic Valve Replacement with Newer Generation Devices

    Get PDF
    The superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS) has not been fully demonstrated in a real-world setting. This prospective study included 5706 AS patients who underwent SAVR from 2010 to 2012 and 2989 AS patients who underwent TAVR from 2017 to 2018 from the prospective multicenter observational studies OBSERVANT I and II. Early adverse events as well as all-cause mortality, major adverse cardiac and cerebrovascular events (MACCEs), and hospital readmission due to heart failure at 1-year were investigated. Among 1008 propensity score matched pairs, TAVR was associated with significantly lower 30-day mortality (1.8 vs. 3.5%, p = 0.020), stroke (0.8 vs. 2.3%, p = 0.005), and acute kidney injury (0.6 vs. 8.2%, p < 0.001) compared to SAVR. Moderate-to-severe paravalvular regurgitation (5.9 vs. 2.0%, p < 0.001) and permanent pacemaker implantation (13.8 vs. 3.3%, p < 0.001) were more frequent after TAVR. At 1-year, TAVR was associated with lower risk of all-cause mortality (7.9 vs. 11.5%, p = 0.006), MACCE (12.0 vs. 15.8%, p = 0.011), readmission due to heart failure (10.8 vs. 15.9%, p < 0.001), and stroke (3.2 vs. 5.1%, p = 0.033) compared to SAVR. TAVR reduced 1-year mortality in the subgroups of patients aged 80 years or older (HR 0.49, 95% CI 0.33-0.71), in females (HR 0.57, 0.38-0.85), and among patients with EuroSCORE II >= 4.0% (HR 0.48, 95% CI 0.32-0.71). In a real-world setting, TAVR using new-generation devices was associated with lower rates of adverse events up to 1-year follow-up compared to SAVR

    One-Year Outcomes and Trends over Two Eras of Transcatheter Aortic Valve Implantation in Real-World Practice

    No full text
    Background: Data reflecting the benefit of procedural improvements in real-world transcatheter aortic valve implantation (TAVI) practice are sparse. Aims: To compare outcomes and trends of two TAVI eras from real Italian practice. Methods: A total of 1811 and 2939 TAVI patients enrolled in the national, prospective OBSERVANT and OBSERVANT II studies in 2010–2012 and 2016–2018, respectively, were compared in a cohort study. Outcomes were adjusted using inverse propensity of treatment weighting and propensity score matching. Results: The median age (83.0 (79.0–86.0) vs. 83.0 (79.0–86.0)) and EuroSCORE II (5.2 (3.2–7.7) vs. 5.1 (3.1–8.1)) of OBSERVANT and OBSERVANT II patients were similar. At 1 year, patients of the OBSERVANT II study had a significantly lower risk of all-cause death (10.6% vs. 16.3%, Hazard Ratio (HR) 0.63 (95% Confidence Interval (CI) 0.52–0.76)) and rehospitalization for heart failure (HF) (14.3% vs. 19.5%, Sub-distribution HR 0.71 (95%CI 0.60–0.84)), whereas rates of stroke (3.1% vs. 3.6%) and permanent pacemaker implantation (PPI) (16.6% vs. 18.0%) were comparable between study groups. Conclusions: Age and risk profile among patients undergoing TAVI in Italy remained substantially unchanged between the 2010–2012 and 2016–2018 time periods. After adjustment, patients undergoing TAVI in the most recent era had lower risk of all-cause death and rehospitalization for HF at 1 year, whereas rates of stroke and PPI did not differ significantly

    One-Year Outcomes after Surgical versus Transcatheter Aortic Valve Replacement with Newer Generation Devices

    No full text
    The superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS) has not been fully demonstrated in a real-world setting. This prospective study included 5706 AS patients who underwent SAVR from 2010 to 2012 and 2989 AS patients who underwent TAVR from 2017 to 2018 from the prospective multicenter observational studies OBSERVANT I and II. Early adverse events as well as all-cause mortality, major adverse cardiac and cerebrovascular events (MACCEs), and hospital readmission due to heart failure at 1-year were investigated. Among 1008 propensity score matched pairs, TAVR was associated with significantly lower 30-day mortality (1.8 vs. 3.5%, p = 0.020), stroke (0.8 vs. 2.3%, p = 0.005), and acute kidney injury (0.6 vs. 8.2%, p < 0.001) compared to SAVR. Moderate-to-severe paravalvular regurgitation (5.9 vs. 2.0%, p < 0.001) and permanent pacemaker implantation (13.8 vs. 3.3%, p < 0.001) were more frequent after TAVR. At 1-year, TAVR was associated with lower risk of all-cause mortality (7.9 vs. 11.5%, p = 0.006), MACCE (12.0 vs. 15.8%, p = 0.011), readmission due to heart failure (10.8 vs. 15.9%, p < 0.001), and stroke (3.2 vs. 5.1%, p = 0.033) compared to SAVR. TAVR reduced 1-year mortality in the subgroups of patients aged 80 years or older (HR 0.49, 95% CI 0.33–0.71), in females (HR 0.57, 0.38–0.85), and among patients with EuroSCORE II ≥ 4.0% (HR 0.48, 95% CI 0.32–0.71). In a real-world setting, TAVR using new-generation devices was associated with lower rates of adverse events up to 1-year follow-up compared to SAVR

    One-Year Outcomes and Trends over Two Eras of Transcatheter Aortic Valve Implantation in Real-World Practice

    No full text
    Background: Data reflecting the benefit of procedural improvements in real-world transcatheter aortic valve implantation (TAVI) practice are sparse. Aims: To compare outcomes and trends of two TAVI eras from real Italian practice. Methods: A total of 1811 and 2939 TAVI patients enrolled in the national, prospective OBSERVANT and OBSERVANT II studies in 2010–2012 and 2016–2018, respectively, were compared in a cohort study. Outcomes were adjusted using inverse propensity of treatment weighting and propensity score matching. Results: The median age (83.0 (79.0–86.0) vs. 83.0 (79.0–86.0)) and EuroSCORE II (5.2 (3.2–7.7) vs. 5.1 (3.1–8.1)) of OBSERVANT and OBSERVANT II patients were similar. At 1 year, patients of the OBSERVANT II study had a significantly lower risk of all-cause death (10.6% vs. 16.3%, Hazard Ratio (HR) 0.63 (95% Confidence Interval (CI) 0.52–0.76)) and rehospitalization for heart failure (HF) (14.3% vs. 19.5%, Sub-distribution HR 0.71 (95%CI 0.60–0.84)), whereas rates of stroke (3.1% vs. 3.6%) and permanent pacemaker implantation (PPI) (16.6% vs. 18.0%) were comparable between study groups. Conclusions: Age and risk profile among patients undergoing TAVI in Italy remained substantially unchanged between the 2010–2012 and 2016–2018 time periods. After adjustment, patients undergoing TAVI in the most recent era had lower risk of all-cause death and rehospitalization for HF at 1 year, whereas rates of stroke and PPI did not differ significantly
    corecore