Decline in subarachnoid haemorrhage volumes associated with the first wave of the COVID-19 pandemic
BACKGROUND: During the COVID-19 pandemic, decreased volumes of stroke admissions and mechanical thrombectomy were reported. The study\u27s objective was to examine whether subarachnoid haemorrhage (SAH) hospitalisations and ruptured aneurysm coiling interventions demonstrated similar declines.
METHODS: We conducted a cross-sectional, retrospective, observational study across 6 continents, 37 countries and 140 comprehensive stroke centres. Patients with the diagnosis of SAH, aneurysmal SAH, ruptured aneurysm coiling interventions and COVID-19 were identified by prospective aneurysm databases or by International Classification of Diseases, 10th Revision, codes. The 3-month cumulative volume, monthly volumes for SAH hospitalisations and ruptured aneurysm coiling procedures were compared for the period before (1 year and immediately before) and during the pandemic, defined as 1 March-31 May 2020. The prior 1-year control period (1 March-31 May 2019) was obtained to account for seasonal variation.
FINDINGS: There was a significant decline in SAH hospitalisations, with 2044 admissions in the 3 months immediately before and 1585 admissions during the pandemic, representing a relative decline of 22.5% (95% CI -24.3% to -20.7%, p\u3c0.0001). Embolisation of ruptured aneurysms declined with 1170-1035 procedures, respectively, representing an 11.5% (95%CI -13.5% to -9.8%, p=0.002) relative drop. Subgroup analysis was noted for aneurysmal SAH hospitalisation decline from 834 to 626 hospitalisations, a 24.9% relative decline (95% CI -28.0% to -22.1%, p\u3c0.0001). A relative increase in ruptured aneurysm coiling was noted in low coiling volume hospitals of 41.1% (95% CI 32.3% to 50.6%, p=0.008) despite a decrease in SAH admissions in this tertile.
INTERPRETATION: There was a relative decrease in the volume of SAH hospitalisations, aneurysmal SAH hospitalisations and ruptured aneurysm embolisations during the COVID-19 pandemic. These findings in SAH are consistent with a decrease in other emergencies, such as stroke and myocardial infarction
Recommended from our members
Dual Layer vs Single Layer Woven EndoBridge Device in the Treatment of Intracranial Aneurysms: A Propensity Score-Matched Analysis
The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms.
A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture.
Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23).
The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up
Recommended from our members
Defining ideal middle cerebral artery bifurcation aneurysm size for Woven EndoBridge embolization
OBJECTIVE The Woven EndoBridge (WEB) device was approved to treat wide-necked bifurcation aneurysms. The device is designed as an intrasaccular flow disruptor covering aneurysm widths up to 10 mm. Although prior studies combined all aneurysm sizes, it is known that aneurysms behave differently in response to endovascular treatment based on their size. Therefore, the authors’ objective was to identify ideal middle cerebral artery (MCA) aneurysm width and neck sizes most suitable for WEB treatment. METHODS The WorldWideWEB consortium is a large multicenter retrospective database that analyzes intracranial aneurysms treated with the WEB device. In this study, all unruptured MCA bifurcation aneurysms with available measurements were included. Cutoff values based on aneurysm width and neck in relation to aneurysm occlusion status were measured using the receiver operating characteristic (ROC) curve. Propensity score matching (PSM) was then used to compare treatment outcomes between aneurysms smaller and larger than the cutoff value for both width and neck size. RESULTS The ideal cutoff values for MCA bifurcation aneurysm width and neck were 6.1 mm and 4.6 mm, respectively. On PSM, 87 matched pairs were compared based on width size (≤ 6.1 mm and > 6.1 mm), and 77 matched pairs were compared based on neck size (≤ 4.6 mm and > 4.6 mm). There was a significant difference in adequate aneurysm occlusion between aneurysms smaller and larger than those cutoff values for both widths (93% vs 76%, p = 0.0017) and neck sizes (90% vs 70%, p = 0.0026). The retreatment rate was also significantly higher for larger aneurysms in both parameters. CONCLUSIONS This study shows that MCA bifurcation aneurysms ≤ 6.1 mm in width and ≤ 4.6 mm in neck size are significantly better candidates for WEB treatment, leading to improved occlusion status and reduced retreatment rate, which are important considerations when using WEB devices
Recommended from our members
Association of preprocedural antiplatelet use with decreased thromboembolic complications for intracranial aneurysms undergoing intrasaccular flow disruption
This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates.
A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation.
The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024).
The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence
Recommended from our members
Off-Label Use of Woven EndoBridge Device for Intracranial Brain Aneurysm Treatment: Modeling of Occlusion Outcome
The Woven EndoBridge (WEB) device is emerging as a novel therapy for intracranial aneurysms, but its use for off-label indications requires further study. Using machine learning, we aimed to develop predictive models for complete occlusion after off-label WEB treatment and to identify factors associated with occlusion outcomes.
This multicenter, retrospective study included 162 patients who underwent off-label WEB treatment for intracranial aneurysms. Baseline, morphological, and procedural variables were utilized to develop machine-learning models predicting complete occlusion. Model interpretation was performed to determine significant predictors. Ordinal regression was also performed with occlusion status as an ordinal outcome from better (Raymond Roy Occlusion Classification [RROC] grade 1) to worse (RROC grade 3) status. Odds ratios (OR) with 95% confidence intervals (CI) were reported.
The best performing model achieved an AUROC of 0.8 for predicting complete occlusion. Larger neck diameter and daughter sac were significant independent predictors of incomplete occlusion. On multivariable ordinal regression, higher RROC grades (OR 1.86, 95% CI 1.25-2.82), larger neck diameter (OR 1.69, 95% CI 1.09-2.65), and presence of daughter sacs (OR 2.26, 95% CI 0.99-5.15) were associated with worse aneurysm occlusion after WEB treatment, independent of other factors.
This study found that larger neck diameter and daughter sacs were associated with worse occlusion after WEB therapy for aneurysms. The machine learning approach identified anatomical factors related to occlusion outcomes that may help guide patient selection and monitoring with this technology. Further validation is needed
Recommended from our members
Creation of a predictive calculator to determine adequacy of occlusion of the woven endobridge (WEB) device in intracranial aneurysms—A retrospective analysis of the WorldWide WEB Consortium database
Background Endovascular treatment with the woven endobridge (WEB) device has been widely utilized for managing intracranial aneurysms. However, predicting the probability of achieving adequate occlusion (Raymond–Roy classification 1 or 2) remains challenging. Objective Our study sought to develop and validate a predictive calculator for adequate occlusion using the WEB device via data from a large multi-institutional retrospective cohort. Methods We used data from the WorldWide WEB Consortium, encompassing 356 patients from 30 centers across North America, South America, and Europe. Bivariate and multivariate regression analyses were performed on a variety of demographic and clinical factors, from which predictive factors were selected. Calibration and validation were conducted, with variance inflation factor (VIF) parameters checked for collinearity. Results A total of 356 patients were included: 124 (34.8%) were male, 108 (30.3%) were elderly (≥65 years), and 118 (33.1%) were current smokers. Mean maximum aneurysm diameter was 7.09 mm (SD 2.71), with 112 (31.5%) having a daughter sac. In the multivariate regression, increasing aneurysm neck size (OR 0.706 [95% CI: 0.535–0.929], p = 0.13) and partial aneurysm thrombosis (OR 0.135 [95% CI: 0.024–0.681], p = 0.016) were found to be the only statistically significant variables associated with poorer likelihood of achieving occlusion. The predictive calculator shows a c-statistic of 0.744. Hosmer–Lemeshow goodness-of-fit test indicated a satisfactory model fit with a p-value of 0.431. The calculator is available at: https://neurodx.shinyapps.io/WEBDEVICE/ . Conclusion The predictive calculator offers a substantial contribution to the clinical toolkit for estimating the likelihood of adequate intracranial aneurysm occlusion by WEB device embolization