960 research outputs found

    A multi-layer edge-on single photon counting silicon microstrip detector for innovative techniques in diagnostic radiology

    Get PDF
    A three-layer detector prototype, obtained by stacking three edge-on single photon counting silicon microstrip detectors, has been developed and widely tested. This was done in the framework of the Synchrotron Radiation for Medical Physics/Frontier Radiology (SYRMEP/FRONTRAD) collaboration activities, whose aim is to improve the quality of mammographic examinations operating both on the source and on the detector side. The active surface of the device has been fully characterized making use of an edge-scanning technique and of a well-collimated laminar synchrotron radiation beam. The obtained data (interlayer distances, channel correspondence, etc.) have then been used to combine information coming from each detector layer, without causing any loss in spatial and contrast resolution of the device. Contrast and spatial resolution have also been separately evaluated for each detector layer. Moreover, imaging techniques (phase contrast, refraction, and scatter imaging), resulting in an increased visibility of low absorbing details, have been implemented, and their effectiveness has been tested on a biological sample. Finally, the possibility of simultaneously acquiring different kind of images with the different detector layers is discussed. This would result in maximizing the information extracted from the sample, while at the same time the high absorption efficiency of the detector device would allow a low dose delivery

    Digital Correlation of Ion and Optical Microscopic Images: Application to the Study of Thyroglobulin Chemical Modification

    Get PDF
    A method has been developed in order to digitally correlate ion and optical microscopic images of the same sample areas. Serial cross-sections of human thyroid tissue were analyzed by secondary ion mass microscopy and by light microscopy. The resulting chemical and immunochemical map images were superimposed and correlated by means of a two-pass registration algorithm which allows to correct for geometrical distortions introduced by the ion microscope. Results are presented for the study of thyroglobulin chemical modification in pathological thyroid tissue that demonstrates heterogeneous molecular activity

    Effect of different scintillator choices on the x-ray imaging performance of CMOS sensors

    Get PDF
    The ability of wafer scale Complementary Metal Oxide Semiconductor (CMOS) imagers to integrate sensing with analogue to digital conversion at the pixel level has led to their widespread appeal in a variety of imaging applications. This has led to significant improvement in speed and reduction in read-out noise in these imagers when compared to charge-coupled devices (CCDs) and amorphous silicon/selenium based flat panel imagers (FPIs). This paper compares the performance characteristics of CMOS X-ray detectors in various configurations by varying certain parameters of a typical X-ray detector such as fibre optic face plate (FOP), scintillator substrate coating, sensor pixel pitch and scintillator thickness. The evaluations were carried out using RQA5 (70 kV) radiation beam quality aimed at general radiography applications. At comparable Air Kerma values, detectors with a fibre optic plate showed an overall better DQE performance at most spatial frequencies, starting slightly lower at low frequencies then overtaking the “no-FOP” case at mid and high frequencies. The analysis of detectors with different substrate coatings for the scintillators showed comparatively higher DQE for the white-coated aluminium substrate scintillator compared to the black-coated one. The DQE comparison of detectors with and pixel pitch resulted in a higher DQE for the pixel pitch one, with the caveat that the scintillator was thick enough as to render differences in pMTF negligible. Finally, the comparison of scintillators with varying thicknesses showed that the thickest scintillator yielded the highest DQE. These characterisation studies helped in understanding the suitability of these different configurations in various general radiography application scenarios and could be of help to prospective users to determine the overall configuration that best fits their specific imaging needs

    Laser-wakefield accelerators for medical phase contrast imaging : Monte Carlo simulations and experimental studies

    Get PDF
    X-ray phase contrast imaging (X-PCi) is a very promising method of dramatically enhancing the contrast of X-ray images of microscopic weakly absorbing objects and soft tissue, which may lead to significant advancement in medical imaging with high-resolution and low-dose. The interest in X-PCi is giving rise to a demand for effective simulation methods. Monte Carlo codes have been proved a valuable tool for studying X-PCi including coherent effects. The laser-plasma wakefield accelerators (LWFA) is a very compact particle accelerator that uses plasma as an accelerating medium. Accelerating gradient in excess of 1 GV/cm can be obtained, which makes them over a thousand times more compact than conventional accelerators. LWFA are also sources of brilliant betatron radiation, which are promising for applications including medical imaging. We present a study that explores the potential of LWFA-based betatron sources for medical X-PCi and investigate its resolution limit using numerical simulations based on the FLUKA Monte Carlo code, and present preliminary experimental result

    A method for high-energy, low-dose mammography using edge illumination x-ray phase-contrast imaging

    Get PDF
    Since the breast is one of the most radiosensitive organs, mammography is arguably the area where lowering radiation dose is of the uttermost importance. Phase-based x-ray imaging methods can provide opportunities in this sense, since they do not require x-rays to be stopped in tissue for image contrast to be generated. Therefore, x-ray energy can be considerably increased compared to those usually exploited by conventional mammography. In this article we show how a novel, optimized approach can lead to considerable dose reductions. This was achieved by matching the edge-illumination phase method, which reaches very high angular sensitivity also at high x-ray energies, to an appropriate image processing algorithm and to a virtually noise-free detection technology capable of reaching almost 100% efficiency at the same energies. Importantly, while proof-of-concept was obtained at a synchrotron, the method has potential for a translation to conventional sources

    Monochromatic Propagation-Based Phase-Contrast Microscale Computed-Tomography System with a Rotating-Anode Source

    Get PDF
    We present an experimental setup for monochromatic propagation-based x-ray phase-contrast imaging based on a conventional rotating-copper-anode source, capable of an integrated flux up to 108 photons/s at 8 keV. In our study, the system is characterized in terms of spatial coherence, resolution, contrast sensitivity, and stability. Its quantitativeness is demonstrated by comparing theoretical predictions with experimental data on simple wire phantoms both in planar and computerized-tomography-scan geometries. Application to two biological samples of medical interest shows the potential for bioimaging on the millimeter scale with spatial resolution of the order of 10 \u3bcm and contrast resolution below 1%. All the scans are performed within laboratory-compatible exposure times, from 10 min to a few hours, and trade-offs between scan time and image quality are discussed

    redefining the pulvinar sign in fabry disease

    Get PDF
    BACKGROUND AND PURPOSE: The pulvinar sign refers to exclusive T1WI hyperintensity of the lateral pulvinar. Long considered a common sign of Fabry disease, the pulvinar sign has been reported in many pathologic conditions. The exact incidence of the pulvinar sign has never been tested in representative cohorts of patients with Fabry disease. The aim of this study was to assess the prevalence of the pulvinar sign in Fabry disease by analyzing T1WI in a large Fabry disease cohort, determining whether relaxometry changes could be detected in this region independent of the pulvinar sign positivity. MATERIALS AND METHODS: We retrospectively analyzed brain MR imaging of 133 patients with Fabry disease recruited through specialized care clinics. A subgroup of 26 patients underwent a scan including 2 FLASH sequences for relaxometry that were compared with MRI scans of 34 healthy controls. RESULTS: The pulvinar sign was detected in 4 of 133 patients with Fabry disease (3.0%). These 4 subjects were all adult men (4 of 53, 7.5% of the entire male population) with renal failure and under enzyme replacement therapy. When we tested for discrepancies between Fabry disease and healthy controls in quantitative susceptibility mapping and relaxometry maps, no significant difference emerged for any of the tested variables. CONCLUSIONS: The pulvinar sign has a significantly lower incidence in Fabry disease than previously described. This finding, coupled with a lack of significant differences in quantitative MR imaging, allows hypothesizing that selective involvement of the pulvinar is a rare neuroradiologic sign of Fabry disease

    Mindfulness-based interventions for young offenders: a scoping review

    Get PDF
    Youth offending is a problem worldwide. Young people in the criminal justice system have frequently experienced adverse childhood circumstances, mental health problems, difficulties regulating emotions and poor quality of life. Mindfulness-based interventions can help people manage problems resulting from these experiences, but their usefulness for youth offending populations is not clear. This review evaluated existing evidence for mindfulness-based interventions among such populations. To be included, each study used an intervention with at least one of the three core components of mindfulness-based stress reduction (breath awareness, body awareness, mindful movement) that was delivered to young people in prison or community rehabilitation programs. No restrictions were placed on methods used. Thirteen studies were included: three randomized controlled trials, one controlled trial, three pre-post study designs, three mixed-methods approaches and three qualitative studies. Pooled numbers (n = 842) comprised 99% males aged between 14 and 23. Interventions varied so it was not possible to identify an optimal approach in terms of content, dose or intensity. Studies found some improvement in various measures of mental health, self-regulation, problematic behaviour, substance use, quality of life and criminal propensity. In those studies measuring mindfulness, changes did not reach statistical significance. Qualitative studies reported participants feeling less stressed, better able to concentrate, manage emotions and behaviour, improved social skills and that the interventions were acceptable. Generally low study quality limits the generalizability of these findings. Greater clarity on intervention components and robust mixed-methods evaluation would improve clarity of reporting and better guide future youth offending prevention programs

    Corpus callosum involvement: a useful clue for differentiating Fabry Disease from Multiple Sclerosis.

    Get PDF
    PURPOSE: Multiple sclerosis (MS) has been proposed as a possible differential diagnosis for Fabry disease (FD). The aim of this work was to evaluate the involvement of corpus callosum (CC) on MR images and its possible role as a radiological sign to differentiate between FD and MS. METHODS: In this multicentric study, we retrospectively evaluated the presence of white matter lesions (WMLs) on the FLAIR images of 104 patients with FD and 117 patients with MS. The incidence of CC-WML was assessed in the two groups and also in a subgroup of 37 FD patients showing neurological symptoms. RESULTS: WMLs were detected in 50 of 104 FD patients (48.1%) and in all MS patients. However, a lesion in the CC was detected in only 3 FD patients (2.9%) and in 106 MS patients (90.6%). In the FD subgroup with neurological symptoms, WMLs were present in 26 of 37 patients (70.3%), with two subjects (5.4%) showing a definite callosal lesion. CONCLUSION: FD patients have a very low incidence of CC involvement on conventional MR images compared to MS, independently from the clinical presentation and the overall degree of WM involvement. Evaluating the presence of CC lesions on brain MR scans can be used as a radiological sign for a differential diagnosis between MS and FD, rapidly addressing the physician toward a correct diagnosis and subsequent treatment options
    corecore