68 research outputs found

    Role and Utility of Mixed Reality Technology in Laparoscopic Partial Nephrectomy: Outcomes of a Prospective RCT Using an Indigenously Developed Software

    Full text link
    OBJECTIVE: To develop a software for mixed reality (MR) anatomical model creation and study its intraoperative clinical utility to facilitate laparoscopic partial nephrectomy. MATERIALS AND METHODS: After institutional review board approval, 47 patients were prospectively randomized for LPN into two groups: the control group (24 patients) underwent operation with an intraoperative ultrasound (US) control and the experimental group (23 patients) with smart glasses HoloLens 2 (Microsoft, Seattle, WA, USA). Our team has developed an open-source software package called “HLOIA,” utilization of which allowed to create and use during surgery the MR anatomical model of the kidney with its vascular pedicle and tumor. The study period extended from June 2020 to February 2021 where demographic, perioperative, and pathological data were collected for all qualifying patients. The objective was to assess the utility of a MR model during LPN and through a 5-point Likert scale questionnaire, completed by the surgeon, immediately after LPN. Patient characteristics were tested using the chi-square test for categorical variables and Student's t-test or Mann–Whitney test for continuous variables. RESULTS: Comparison of the variables between the groups revealed statistically significant differences only in the following parameters: the time for renal pedicle exposure and the time from the renal pedicle to the detection of tumor localization (p < 0.001), which were in favor of the experimental group. The surgeon's impression of the utility of the MR model by the proposed questionnaire demonstrated high scores in all statements. CONCLUSIONS: Developed open-source software “HLOIA” allowed to create the mixed reality anatomical model by operating urologist which is when used with smart glasses has shown improvement in terms of time for renal pedicle exposure and time for renal tumor identification without compromising safety

    Multi-institutional Evaluation of Producing and Testing a Novel 3D-Printed Laparoscopic Trainer

    Get PDF
    To create, distribute, and evaluate the efficacy of a portable, cost effective 3D-printed laparoscopic trainer for surgical skills development.Objective: To create, distribute, and evaluate the efficacy of a portable, cost-effective 3D-printed laparoscopic trainer for surgical skills development. Methods: The UCI Trainer (UCiT) laparoscopic simulator was developed via computer-aided designs (CAD), which were used to 3D-print the UCiT. Once assembled, a tablet computer with a rear-facing camera was attached for video and optics. Four institutions were sent the UCiT CAD files with a 3D-printer and instructions for UCiT assembly. For a comparison of the UCiT to a standard trainer, peg transfer and intracorporeal knot tying skills were accessed. These tasks were scored, and participants were asked to rate their experience with the trainers. Lastly, a questionnaire was given to individuals who 3D-printed and assembled the UCiT. Results: We recruited 25 urologists; none had any 3D-printing experience. The cost of printing each trainer was $26.50 USD. Each institution used the Apple iPad for optics. Six of eight participants assembled the UCiT in &lt; 45 minutes, and rated assembly as somewhat easy. On objective scoring, participants performed tasks equally well on the UCiT vs the conventional trainer. On subjective scoring, the conventional trainer provided a significantly better experience vs the UCiT; however, all reported that the UCiT was useful for surgical education. Conclusion: The UCiT is a low cost, portable training tool that is easy to assemble and use. UCiT provided a platform whereby participants performed laparoscopic tasks equal to performing the same tasks on the more expensive, nonportable standard trainer

    New Ultra-minimally Invasive Surgical Treatment for Benign Prostatic Hyperplasia: A Systematic Review and Analysis of Comparative Outcomes

    Get PDF
    Context: Benign prostatic hyperplasia (BPH) associated with lower urinary tract symptoms (LUTS) is diagnosed in up to 80% of men during their lifetime. Several novel ultra-minimally invasive surgical treatments (uMISTs) for BPH/benign prostatic obstruction (BPO) have become available over the past 5 yr. Objective: To evaluate the perioperative and functional outcomes of recently introduced uMISTs for BPH/BPO, including Urolift, Rezūm, temporary implantable nitinol device, prostatic artery embolization (PAE), and intraprostatic injection. Evidence acquisition: A systematic literature search was conducted in December 2020 using Medline (via PubMed), Embase (via Ovid), Scopus, and Web of Science (registered on PROSPERO as CRD42021225014). The search strategy used PICO criteria and article selection was conducted in accordance with the PRISMA guidelines. The risk of bias and the quality of the articles included were assessed. A dedicated data extraction form was used to collect the data of interest. Pooled and cumulative analyses were performed to compare perioperative and functional outcomes between study groups. A random-effects model using the DerSimonian and Laird method was used to evaluate heterogeneity. Stata version 15.0 software was used for all statistical analyses. Evidence synthesis: The initial electronic search identified 3978 papers, of which 48 ultimately met the inclusion criteria and were included in the analysis. Pooled analysis revealed a uMIST benefit in terms of International Prostate Symptom Score (IPSS; −9.81 points, 95% confidence interval [CI] −11.37 to −8.25 at 1 mo; −13.13 points, 95% CI −14.98 to −11.64 at 12 mo), maximum flow rate (from +3.66 ml/s, 95% CI 2.8–4.5 to +4.14 ml/s, 95% CI 0.72–7.56 at 12 mo), and postvoid residual volume (−10.10 ml, 95% CI −27.90 to 7.71 at 12 mo). No negative impact was observed on scores for the International Index of Erectile Function-5, Male Sexual Health Questionnaire-Ejaculatory Dysfunction bother and function scales (overall postintervention change in pooled median score of 1.88, 95% CI 1.34–2.42 at the start of follow-up; and 1.04, 95% CI 0.28–1.8 after 1 yr), or the IPSS-Quality of Life questionnaire. Conclusions: Novel uMISTs can yield fast and effective relief of LUTS without affecting patient quality of life. Only Rezūm, UroLift, and PAE had a minimal impact on patients’ sexual function with respect to baseline, especially regarding preservation of ejaculation. Patient summary: We reviewed outcomes for recently introduced ultra-minimally invasive surgical treatments for patients with lower urinary tract symptoms caused by benign prostate enlargement or obstruction. The evidence suggests that these novel techniques are beneficial in terms of controlling symptoms while preserving sexual function. Take Home Message: Novel ultra-minimally invasive treatments can yield fast and effective relief of lower urinary tract symptoms without affecting a patient's quality of life
    corecore