    Visualization of Stent Lumen in MR Imaging: Relationship with Stent Design and RF Direction

    Get PDF
    Magnetic resonance imaging (MRI) visualization of metallic stent lumens is possible if the stent structure counteracts eddy currents in the lumen induced by the radio frequency magnetic field, B1. To examine the effectiveness of various stent designs in counteracting eddy currents, we anchored eight copper stent models and 2 commercially available nickel-titanium alloy (Nitinol) stents in a gel phantom, perpendicular or parallel to the direction of B1. A mesh stent lumen showed hypointensity irrespective of its alignment relative to B1. A solenoid stent lumen showed hypointensity with the stent axis parallel to B1, but it had the same signal intensity as outside the lumen when perpendicular to B1. A Moebius stent lumen showed no signal reduction, irrespective of alignment relative to B1. Lumens of the commercially available stents showed hypointensity regardless of alignment relative to B1. Computer simulation revealed that the signal intensities of the stents corresponded to magnetic flux densities of B1 in the stents, which are modified by the structure of the stent. While in vivo MRI viewing of a Moebius stent lumen is likely possible regardless of axis alignment, inherent structural weakness may be problematic. As a more practical choice, the solenoid stent is easier to manufacture and generates no hypointensive signal when the axis is parallel to B0

    In Vitro Assessment of Factors Affecting the Apparent Diffusion Coefficient of Ramos Cells Using Bio-phantoms

    Get PDF
    The roles of cell density, extracellular space, intracellular factors, and apoptosis induced by the molecularly targeted drug rituximab on the apparent diffusion coefficient (ADC) values were investigated using bio-phantoms. In these bio-phantoms, Ramos cells (a human Burkittセs lymphoma cell line) were encapsulated in gellan gum. The ADC values decreased linearly with the increase in cell density, and declined steeply when the extracellular space became less than 4 μm. The analysis of ADC values after destruction of the cellular membrane by sonication indicated that approximately 65% of the ADC values of normal cells originate from the cell structures made of membranes and that the remaining 35% originate from intracellular components. Microparticles, defined as particles smaller than the normal cells, increased in number after rituximab treatments, migrated to the extracellular space and significantly decreased the ADC values of bio-phantoms during apoptosis. An in vitro study using bio-phantoms was conducted to quantitatively clarify the roles of cellular factors and of extracellular space in determining the ADC values yielded by tumor cells and the mechanism by which apoptosis changes those values

    Influence on the character of films used for density control of an automatic processor by the difference in the way of preserving

    Get PDF
    自動現像機の濃度管理に用いられるフィルムの保存については,種々の報告がなされており,最良の方法が確立されているとは言い難い。さらに,レギュラフィルムとオルソフィルムの保存方法の違いによる濃度管理への影響,あるいはこれらの比較については,これまでほとんど報告されていない。本論文では,われわれは,レギュラフィルム,フジnew-RXとオルソフィルム,コニカSR-G,SR-VおよびSR-Hを用い,開封後,室温,冷蔵,冷凍の3種類の保存方法を採用した。われわれは,35週間3種類の保存方法で4種類 のフィルムのgross fog,speed indexとaverage gradientへの影響を調査した。その結果レギュラフィルムは,3種類の保存方法による差が認められなかった。オルソフィルムでは,冷蔵・冷凍保存に大きな特性変動が認められた。その原因として,オルソフィルムは増感色素が結露に対して敏感に影響を受けたと考えられた。Though there are various reports on the way of preserving films used for density control of the automatic processor, it is hard to say that the best method isestablished. In addition, the influences on density control or their comparisons by the difference way of preserving film between regular and orthochromatic films have been hardly reported until now. In this paper, three ways of preserving films were employed, which were at a room temperature, in a refrigeration and in a freezer after the films were opened, using a regular film, Fuji new-RX and three orthochromatic films, Konica SR-G, SR-V and SR-H. We investigated the influences on gross fog, speed index and average gradient of four films on three different ways of preserving film for 35 weeks. As a result, new-RX film wasn't influenced by the ways of the preservation. On the other hand, the orthochromatic films were so influences sensitively that the films couldn't be used for density control. It was considered that sensitizing dye stuff got denatured by dew condensation

    The Usefulness of Readout-Segmented Echo-Planar Imaging (RESOLVE) for Bio-phantom Imaging Using 3-Tesla Clinical MRI

    Get PDF
    Readout-segmented echo-planar imaging (RESOLVE) is a multi-shot echo-planar imaging (EPI) modality with k-space segmented in the readout direction. We investigated whether RESOLVE decreases the distortion and artifact in the phase direction and increases the signal-to-noise ratio (SNR) in phantoms image taken with 3-tesla (3T) MRI versus conventional EPI. We used a physiological saline phantom and subtraction mapping and observed that RESOLVE’s SNR was higher than EPI’s. Using RESOLVE, the combination of a special-purpose coil and a large-loop coil had a higher SNR compared to using only a head/neck coil. RESOLVE’s image distortioas less than EPI’s. We used a 120 mM polyethylene glycol phantom to examine the phase direction artifact.vThe range where the artifact appeared in the apparent diffusion coefficient (ADC) image was shorter with RESOLVE compared to EPI. We used RESOLVE to take images of a Jurkat cell bio-phantom: the cell-region ADC was 856×10−6mm2/sec and the surrounding physiological saline-region ADC was 2,951×10−6mm2/sec. The combination of RESOLVE and the 3T clinical MRI device reduced image distortion and improved SNR and the identification of accurate ADC values due to the phase direction artifact reduction. This combination is useful for obtaining accurate ADC values of bio-phantoms

    Development of a novel method for visualizing restricted diffusion using subtraction of apparent diffusion coefficient values

    Get PDF
    In order to visualize restricted diffusion, the present study developed a novel method called 'apparent diffusion coefficient (ADC) subtraction method (ASM)' and compared it with diffusion kurtosis imaging (DKI). The diffusion-weighted images of physiological saline, in addtion to bio-phatoms of low cell density and the highest cell density were obtained using two sequences with different effective diffusion times. Then, the calculated ADC values were subtracted. The mean values and standard deviations (SD) of the ADC values of physiological saline, low cell density and the highest cell density phantoms were 2.95 +/- 0.08x10(-3), 1.90 +/- 0.35x10(-3) and 0.79 +/- 0.05x10(-3) mm(2)/sec, respectively. The mean kurtosis values and SD of DKI were 0.04 +/- 0.01, 0.44 +/- 0.13 and 1.27 +/- 0.03, respectively. The ASM and SD values were 0.25 +/- 0.20x10(4), 0.51 +/- 0.41x10(4) and 4.80 +/- 4.51x10(4) (sec/mm(2))(2), respectively. Using bio-phantoms, the present study demonstrated that DKI exhibits restricted diffusion in the extracellular space. Similarly, ASM may reflect the extent of restricted diffusion in the extracellular space

    Evaluation of the Imaging Process for a Novel Subtraction Method Using Apparent Diffusion Coefficient Values

    Get PDF
    Diffusion-weighted imaging may be used to obtain the apparent diffusion coefficient (ADC), which aids the diagnosis of cerebral infarction and tumors. An ADC reflects elements of free diffusion. Diffusion kurtosis imaging (DKI) has attracted attention as a restricted diffusion imaging technique. The ADC subtraction method (ASM) was developed to visualize restricted diffusion with high resolution by using two ADC maps taken with different diffusion times. We conducted the present study to provide a bridge between the reported basic ASM research and clinical research. We developed new imaging software for clinical use and evaluated its performance herein. This software performs the imaging process automatically and continuously at the pixel level, using ImageJ software. The new software uses a macro or a plugin which is compatible with various operating systems via a Java Virtual Machine. We tested the new imaging software’s performance by using a Jurkat cell bio-phantom, and the statistical evaluation of the performance clarified that the ASM values of 99.98% of the pixels in the bio-phantom and physiological saline were calculated accurately (p<0.001). The new software may serve as a useful tool for future clinical applications and restricted diffusion imaging research