20 research outputs found

    Comparison of selected canine vector-borne diseases between urban animal shelter and rural hunting dogs in Korea

    Get PDF
    A serological survey for Dirofilaria immitis, Anaplasma phagocytophilum, Ehrlichia canis, and Borrelia burgdorferi infections in rural hunting and urban shelter dogs mainly from southwestern regions of the Republic of Korea (South Korea) was conducted. From a total of 229 wild boar or pheasant hunting dogs, the number of serologically positive dogs for any of the four pathogens was 93 (40.6%). The highest prevalence observed was D. immitis (22.3%), followed by A. phagocytophilum (18.8%), E. canis (6.1%) and the lowest prevalence was B. burgdorferi (2.2%). In contrast, stray dogs found within the city limits of Gwangju showed seropositivity only to D. immitis (14.6%), and none of the 692 dogs responded positive for A. phagocytophilum, E. canis or B. burgdorferi antibodies. This study indicates that the risk of exposure to vector-borne diseases in rural hunting dogs can be quite high in Korea, while the urban environment may not be suitable for tick infestation on dogs, as evidenced by the low infection status of tick-borne pathogens in stray dogs

    Analysis of Heating and Cooling Loads of Electrochromic Glazing in High-Rise Residential Buildings in South Korea

    No full text
    This study compares the impact of the recently developed electrochromic glazing technology on load reduction by comparing it with the double-glazing and shading devices that are sold commercially for high-rise residential buildings in Korea. These buildings are similar to large office buildings in terms of their high window-to-wall ratio. The energy consumption of such buildings was simulated using an analytical model of a high-rise residential building. The patterns between the heating and cooling loads were found to be similar to that of office buildings, in that the cooling load was considerably higher than the heating load. This study hypothesizes that the load reduction performance of electrochromic glazing with variable solar control and high solar radiation rejection is superior to that of existing double-glazing products and shading devices. This hypothesis was tested by analyzing the cooling and heating loads of buildings with different types of double glazings. Bleached electrochromic glazing exhibited lower transmittance than colored glass double glazing, low-e double glazing, and double glazing with a shading device, and is thus not effective in reducing heating load. Colored electrochromic glazing provided higher solar radiation rejection than colored glass double glazing and low-e double glazing, and thus is effective in reducing cooling load

    Analysis of Heating and Cooling Loads of Electrochromic Glazing in High-Rise Residential Buildings in South Korea

    No full text
    This study compares the impact of the recently developed electrochromic glazing technology on load reduction by comparing it with the double-glazing and shading devices that are sold commercially for high-rise residential buildings in Korea. These buildings are similar to large office buildings in terms of their high window-to-wall ratio. The energy consumption of such buildings was simulated using an analytical model of a high-rise residential building. The patterns between the heating and cooling loads were found to be similar to that of office buildings, in that the cooling load was considerably higher than the heating load. This study hypothesizes that the load reduction performance of electrochromic glazing with variable solar control and high solar radiation rejection is superior to that of existing double-glazing products and shading devices. This hypothesis was tested by analyzing the cooling and heating loads of buildings with different types of double glazings. Bleached electrochromic glazing exhibited lower transmittance than colored glass double glazing, low-e double glazing, and double glazing with a shading device, and is thus not effective in reducing heating load. Colored electrochromic glazing provided higher solar radiation rejection than colored glass double glazing and low-e double glazing, and thus is effective in reducing cooling load

    Deducing the Optimal Control Method for Electrochromic Triple Glazing through an Integrated Evaluation of Building Energy and Daylight Performance

    No full text
    Electrochromic glass is anticipated as the next generation of solar control glass for construction because it can control the transmittance of the glass itself. This study analyzed building energy and light environment performance by applying electrochromic glass in triple glazing in order to verify both the solar control characteristics of electrochromic glass and its high insulation performance. This paper evaluates the performance of the electrochromic glass developed by our research team in Korea in five control conditions of varying temperatures and solar radiation levels. By analyzing the cooling and heating load, lighting energy, Daylight Glare Index (DGI), and interior illuminance when applying the selected conditions to office buildings, this paper discerns the optimal control conditions for electrochromic glass. To do so, the optical characteristic data of the electrochromic glass was analyzed via an experiment, and the creation of triple glazing for construction was conducted. The performance of electrochromic glass was evaluated by analyzing hourly and yearly data for cooling, heating load, and lighting energy during a typical day in summer and winter. From this analysis, the control condition with an outstanding performance from an energy perspective was identified. The performance of the light environment was assessed, and the EDPI overall evaluation index was used to find the electrochromic glass’ optimum control conditions for integrating energy and light environment

    Evaluation of Building Energy and Daylight Performance of Electrochromic Glazing for Optimal Control in Three Different Climate Zones

    No full text
    The objective of this paper is to analyze the control conditions of the transmittance rate, and determine the conditions that are most optimal with respect to building energy and daylight performance in three climate conditions: Riyadh, Saudi Arabia (hot climate); Inchon, South Korea (hot and cold climate); and Moscow, Russia (cold climate). The analysis was based on the electrochromic glass developed by a research team. Electrochromic glass is a next generation solar control glass that can control the transmittance of the glass itself. Therefore, proper control methods are essential for rational use of this electrochromic glass. To properly control electrochromic glass, daylight performance must be considered, along with building energy (heating, cooling, and lighting). If only building energy is considered, transmittance needs to be lowered during the summer season and increased during the winter season. Controlling electrochromic glass transmittance with such a method would not improve the satisfaction of users and occupants of a building due to the resulting glare. In addition to energy reduction, the basic function of solar control glass is to prevent glare. Therefore, in this study, we develop the Energy and Daylight Performance Index (EDPI) using, to evaluate the combined building energy and daylight performance and deduce the optimal control method for electrochromic glass. In addition, optimal control conditions for the three different climatic regions were obtained. Limitations of this study were that the scope was restricted to the eastern climate region, and that the building analysis model was limited to one climate region. It is expected that the optimal control method could be used as an initial database in the development of a electrochromic glass control system

    Evaluation of Energy and Daylight Performance of Old Office Buildings in South Korea with Curtain Walls Remodeled Using Polymer Dispersed Liquid Crystal (PDLC) Films

    No full text
    Globally, energy standards for new buildings are being reinforced to improve energy efficiency, and remodeling policies are being promoted for old buildings. The South Korean Government is promoting green remodeling projects, and focusing on research and product development to improve the performance of old windows and curtain walls. In line with this, the present study proposes two remodeling methods using polymer dispersed liquid crystal (PDLC) films, which can adjust solar radiation for old office buildings. In addition, energy efficiency improvement and daylight performance according to remodeling were analyzed. Attaching PDLC films to the glass of old curtain walls was analyzed; this can reduce heating and cooling energy, reduce the annual discomfort glare occurrence rate, and increase the annual indoor appropriate illuminance ratio. Furthermore, producing a window by laminating a PDLC film between two sheets of glass and putting it over the existing curtain wall was also analyzed; this can reduce annual building energy consumption and the annual discomfort glare occurrence rate, and improve the annual indoor appropriate illuminance ratio. Therefore, PDLC film is expected to be applicable as a next-generation green remodeling material because using it in remodeling can improve energy efficiency of old office buildings and indoor daylight performance

    Evaluation of Heated Window System to Enhance Indoor Thermal Comfort and Reduce Heating Demands Based on Simulation Analysis in South Korea

    No full text
    Heated glass can be applied to improve windows’ condensation resistance and indoor thermal comfort in buildings. Although this applied technology has advantages, there are still some concerns in practical applications, such as additional energy consumption and control issues. This study evaluates the effectiveness of a heated window heating (HWH) system in terms of thermal comfort and heating energy performance (HEP). The simulation-based analysis is performed to evaluate the effectiveness of the HWH using a residential building model and to compare it with radiant floor heating (RFH) and hybrid heating (HH) systems (i.e., combined HWH and RFH). This study also investigates the peak and cumulative heating loads using HWH systems with various scenarios of control methods and setpoint temperature. The predicted mean vote (PMV) is used as an indoor thermal comfort index. The ratio of cumulative thermal comfort time to the entire heating period is calculated. The results show that HWH and HH can reduce the heating load by up to 65.60% and 50.95%, respectively, compared to RFH. In addition, the times of thermal comfort can be increased by 12.55% and 6.98% with HWH and HH, respectively. However, considering the social practices of South Korea, HH is more suitable than HWH. Further investigations for HH show that a surface setpoint of 26 °C is proper, considering both heating demands and thermal comfort. In addition, the setpoint temperature should be determined considering HEP and the thermal comfort for HWH, and the optimal setpoint temperature was suggested under specific conditions

    Real-time in vivo two-photon imaging study reveals decreased cerebro-vascular volume and increased blood-brain barrier permeability in chronically stressed mice

    Get PDF
    Chronic stress disrupts brain homeostasis and adversely affects the cerebro-vascular system. Even though the effects of chronic stress on brain system have been extensively studied, there are few in vivo dynamic studies on the effects of chronic stress on the cerebro-vascular system. In this study, the effects of chronic stress on cerebral vasculature and BBB permeability were studied using in vivo two-photon (2p) microscopic imaging with an injection of fluorescence-conjugated dextran. Our realtime 2p imaging results showed that chronic stress reduced the vessel diameter and reconstructed vascular volume, regardless of vessel type and branching order. BBB permeability was investigated with two different size of tracers. Stressed animals exhibited a greater BBB permeability to 40-kDa dextran, but not to 70-kDa dextran, which is suggestive of weakened vascular integrity following stress. Molecular analysis revealed significantly higher VEGFa mRNA expression and a reduction in claudin-5. In summary, chronic stress decreases the size of cerebral vessels and increases BBB permeability. These results may suggest that the sustained decrease in cerebro-vascular volume due to chronic stress leads to a hypoxic condition that causes molecular changes such as VEGF and claudin-5, which eventually impairs the function of BBB © The Author(s) 201
    corecore