16 research outputs found

    Staged Sinus Floor Elevation Using Novel Low-Crystalline Carbonate Apatite Granules : Prospective Results after 3-Year Functional Loading

    Get PDF
    The aim of this study was to evaluate clinical outcomes of staged sinus floor elevation (SFE) using novel low-crystalline carbonate apatite (CO3Ap) granules. Patients who needed SFE for implant placement were recruited into this clinical trial. A staged procedure (lateral window technique using CO3Ap granules, followed by implant placement after 7 ± 2 months) was employed in 13 patients. Bone-height increase and insertion torque values (ITVs) were assessed along with histological evaluation. The survival and success rates of 3-year functioning implants were also evaluated. Mean of bone-height increase after SFE using CO3Ap granules was 7.2 ± 2.5 mm and this increase allowed implant placement in all cases (17 implants). Mean of ITV was 25.1 ± 13.2 Ncm and primary stability was achieved successfully in all cases. Histological analyses revealed mature new bone formation (36.8 ± 17.3%) and residual CO3Ap granules (16.2 ± 10.1%) in the compartment after SFE. The survival and success rates after 3-year functional loading were 100% and no complications were found. These results clearly indicate the clinical usefulness of CO3Ap granules for SFE

    RhoA-Mediated Functions in C3H10T1/2 Osteoprogenitors Are Substrate Topography Dependent: TOPOGRAPHY-DEPENDENT RhoA MEDIATED FUNCTIONS

    Get PDF
    Surface topography broadly influences cellular responses. Adherent cell activities are regulated, in part, by RhoA, a member of the Rho-family of GTPases. In this study, we evaluated the influence of surface topography on RhoA activity and associated cellular functions. The murine mesenchymal stem cell line C3H10T1/2 cells (osteoprogenitor cells) were cultured on titanium substrates with smooth topography (S), microtopography (M), and nanotopography (N) to evaluate the effect of surface topography on RhoA-mediated functions (cell spreading, adhesion, migration, and osteogenic differentiation). The influence of RhoA activity in the context of surface topography was also elucidated using RhoA pharmacologic inhibitor. Following adhesion, M and N adherent cells developed multiple projections, while S adherent cells had flattened and widespread morphology. RhoA inhibitor induced remarkable longer and thinner cytoplasmic projections on all surfaces. Cell adhesion and osteogenic differentiation was topography dependent with S < M and N surfaces. RhoA inhibition increased adhesion on S and M surfaces, but not N surfaces. Cell migration in a wound healing assay was greater on S versus M versus N surfaces and RhoA inhibitor increased S adherent cell migration, but not N adherent cell migration. RhoA inhibitor enhanced osteogenic differentiation in S adherent cells, but not M or N adherent cells. RhoA activity was surface topography roughness dependent (S < M, N). RhoA activity and -mediated functions are influenced by surface topography. Smooth surface adherent cells appear highly sensitive to RhoA function, while nano-scale topography adherent cell may utilize alternative cellular signaling pathway(s) to influence adherent cellular functions regardless of RhoA activity

    Oral Rehabilitation from Oral and Dental Diseases

    No full text
    Oral conditions, such as the number of teeth and oral hygiene, are related to oral functions and oral health-related quality of life (QoL) [...

    Analyses of Swallowing Function and Its Related Factors in Community-Dwelling Elderly Patients: A Case-Control Study

    No full text
    This retrospective case-control study evaluated the prevalence of declined swallowing function and the association with oral functions and gender in community-dwelling elderly patients. Their profiles, the results of swallowing function (Eating Assessment Tool: EAT-10) and other oral functions (oral dryness, maximum occlusal force (MOF), tongue–lip motor function (oral diadochokinesis: ODK), maximum tongue pressure (MTP) and masticatory performance (MP)) were extracted for analyses. The patients were categorized into three groups according to EAT-10 score (Group 1: 0, Group 2: 1 and 2, Group 3: ≥3). In total, 242 patients were enrolled and 46 of them (19.0%) were categorized into declined swallowing function (Group 3). In two-group comparisons (Group 1, 2 versus Group 3), significant differences were identified in age and the number of remaining teeth, but they were not identified in three-group comparisons. The patients with declined swallowing function (Group 3) had significantly lower function in ODK and MTP. Multiple logistic regression analyses identified that declined swallowing function was independently associated with declined functions in ODK /ka/ (OR: 5.31, 95% CI: 1.03–27.23, p = 0.04) and in MTP (OR: 2.74, 95% CI: 1.12–6.66, p = 0.03). This study could confirm the critical role of tongue functions in swallowing in community-dwelling elderly patients

    Accuracy Assessment of Implant Placement in a Newly Developed Dynamic Navigation System: A Pilot Study

    No full text
    The aim of this pilot study was to evaluate the accuracy of a newly developed dynamic navigation system and to compare the accuracy between flapless and open-flap surgery, and between surgeons. The subjects were patients who were scheduled to receive implants of the same size using the newly developed dynamic navigation system. The study’s procedures included cone beam computed tomography (CBCT) filming with fiducials, virtual planning of implant placement and the use of motion tracking technology for calibration and practical implant placement. The accuracy was evaluated using preoperative (virtual implant) and postoperative (actual implant) CBCT images based on angular, apical, coronal and vertical deviations. The differences of deviations between flapless and open-flap surgery, and between two surgeons, were statistically compared. In total, 66 implants were placed in 39 patients. The median and interquartile range of angular, apical, coronal and vertical deviations were 3.07° (2.52–3.54°), 0.96 mm (0.75–1.42 mm), 0.76 mm (0.57–1.37 mm) and 0.71 mm (0.61–0.88 mm), respectively. These deviations were similar to those found in previous studies. Flapless surgery resulted in a more accurate placement with respect to apical and coronal deviations, and the differences between the two surgeons were limited. The newly developed dynamic navigation system is considered to be eligible for clinical use

    A Prospective Comparative Study of Mastication Predominance and Masticatory Performance in Kennedy Class I Patients

    No full text
    Mastication predominance in Kennedy class I (KC I) patients has not been well defined. This study aimed to investigate mastication predominance and masticatory performance in KC I patients, including the significance of remaining posterior teeth and removable partial-denture (RPD) treatment. KC I patients who had differences in the number of posterior teeth between left and right sides (D+) and KC I patients who had no differences (D−) were enrolled. Healthy dentate (HD) subjects were also registered as a positive control. Mastication predominance, defined by mastication predominance index (MPI; range 0–100%) calculated from electromyogram activities during voluntary chewing, and masticatory performance were evaluated at pre- and post-RPD treatment. Pre-MPI in KC I D+ was significantly higher than in HD. RPD treatment could significantly improve MPI and masticatory performance in both KC I groups. However, there were significant differences in masticatory performance between each KC I group and HD, regardless of RPD treatment. It was considered that the mastication predominance in KC I patients was affected by the difference in the number of remaining posterior teeth. RPD treatment could improve mastication predominance and masticatory performance in KC I patients, although the latter was not similar to HD group

    In Vitro Assessment of the Effect of Implant Position on Biomechanical Behaviors of Implant-Supported Removable Partial Dentures in Kennedy Class II Condition

    No full text
    The purpose of this study was to investigate the effects of implant position and loading position on biomechanical behaviors using implant-supported removable partial denture (ISRPD) models in a simulated Kennedy class Ⅱ partially edentulous mandible. Three types of Kennedy class Ⅱ mandibular acrylic resin models (a conventional RPD without support by an implant—CRPD; models with an implant placed at first molar (#46)—MP-ISRPD— and second molar (#47)—DP-ISRPD) were used to measure vertical displacement of the RPD, mesio-distal displacement of the abutment tooth, and bending moment of the abutment tooth and implant under one-point loading. The variables at three respective loading points (#45, #46 and #47) were compared statistically. Vertical displacement was suppressed in ISRPDs compared to the CRPD, and significant effects were identified under loading at the implant position. The largest meiso-distal displacement was observed in MP-ISRPD under #47 loading. Bending moments of the abutment tooth and implant were significantly higher in MP-ISRPD than in DP-ISPRD. In MP-ISRPD, a higher bending moment of the abutment tooth under #45 and #47 loading was detected, although the bending moment in DP-ISRPD was almost zero. The results of this study suggested that MP-ISRPD shows the specific biomechanical behaviors, although DP-ISRPD might provide biomechanical benefits under all one-point loading conditions
    corecore