10 research outputs found

    A New Methodology to Determine the Orifice for Root Canal Configurations in First Permanent Molar Root and Canal Morphologies Using Micro-Computed Tomography

    Get PDF
    Background: The distinction between where the pulp chamber ends and the root canal system begins is poorly defined within the existing literature. Methods: This paper aimed to describe a range of accurate methods to define the transition from pulp chamber to root canal in different first molar root morphologies using micro-focus computed tomography (micro-CT). Methods: The sample consisted of 86 mandibular and 101 maxillary first molars from the skeletal collections housed in the Department of Anatomy and Histology of the Sefako Makgatho Health Sciences University and the Pretoria Bone Collection. A stepwise approach using the cemento–enamel junction (CEJ) and dedicated landmarks was followed to create an automated cross-sectional slice. Results: Transition from pulp chamber to root canal could be accurately determined on maxillary and mandibular teeth. The occurrence of two separate roots in mandibular molars was 97.7%, with the remaining 2.3% having an additional disto-lingual root, with no mandibular molars displaying fused roots. In the maxillary molars, 92.1% had three separate roots and 7.9% displayed root fusion. Within this group, one tooth displayed a C-shaped root canal configuration and one a mesotaurodont-type morphology. Conclusion: The suggested methodology to determine orifice location was found to be appropriate in all morphological types.</jats:p

    Nose approximation among South African groups from cone-beam computed tomography (CBCT) using a new computer-assisted method based on automatic landmarking.

    No full text
    Considering the high demand for the identification of unknown remains in South Africa, a need exists to establish reliable facial approximation techniques that will take into account sex and age and, most importantly, be useful within the South African context. This study aimed to provide accurate statistical models for predicting nasal soft-tissue shape from information about the underlying skull subtract among a South African sample. The database containing 200 cone-beam computer tomography (CBCT) scans (100 black South Africans and 100 white South Africans). The acquisition and extraction of the 3D relevant anatomical structures (hard- and soft-tissue) were performed by an automated three-dimensional (3D) method based on an automatic dense landmarking procedure using MeVisLab © v. 2.7.1 software. An evaluation of shape differences attributed to known factors (ancestry, sex, size, and age) was performed using geometric morphometric and statistical models of prediction were created using a Projection onto Latent Structures Regression (PLSR) algorithm. The accuracy of the estimated soft-tissue nose was evaluated in terms of metric deviations on training and un-trained datasets. Our findings demonstrated the influence of factors (sex, aging, and allometry) on the variability of the hard- and soft-tissue among two South African population groups. This research provides accurate statistical models optimized by including additional information such as ancestry, sex, and age. When using the landmark-to landmark distances, the prediction errors ranged between 1.769mm and 2.164mm for black South Africans at the tip of the nose and the alae, while they ranged from 2.068mm to 2.175mm for the white subsample. The prediction errors on un-trained data were slightly larger, ranging between 2.139mm and 2.833mm for the black South African sample at the tip of the nose and the alae and ranging from 2.575mm to 2.859mm for the white South African sample. This research demonstrates the utilization of an automated 3Dmethod based on an automatic landmarking method as a convenient prerequisite for providing a valid and reliable nose prediction model that meets population-specific standards for South Africans.status: publishe

    Automatic landmarking as a convenient prerequisite for geometric morphometrics. Validation on cone beam computed tomography (CBCT)- based shape analysis of the nasal complex.

    No full text
    Manual landmarking is used in several manual and semi-automated prediction guidelines for approximation of the nose. The manual placement of landmarks may, however, render the analysis less repeatable due to observer subjectivity and, consequently, have an impact on the accuracy of the human facial approximation. In order to address this subjectivity and thereby improve facial approximations, we are developing an automated three-dimensional (3D) method based on an automatic dense landmarking procedure using non-rigid surface registration. The aim of this study was to validate the automatic landmarking method by comparing the intra-observer errors (INTRA-OE) and inter-observer errors (INTER-OE) between automatic and manual landmarking. Cone beam computed tomography (CBCT) scans of adult South Africans were selected from the Oral and Dental Hospital, University of Pretoria, South Africa. In this study, the validation of the automatic landmarking was performed on 20 3D surfaces. INTRA-OE and INTER-OE were analyzed by registering 41 craniometric landmarks from 10 hard-tissue surfaces and 21 capulometric landmarks from 10 soft-tissue surfaces of the same individuals. Absolute precision of the landmark positioning (both on the samples as well as the template) was assessed by calculating the measurement error (ME) for each landmark over different observers. Systematic error (bias) and relative random error (precision) was further quantified through repeated measures ANOVA (ANOVA-RM). The analysis showed that the random component of the ME in landmark positioning between the automatic observations were on average on par with the manual observations, except for the soft-tissue landmarks where automatic landmarking showed lower ME compared to manual landmarking. No bias was observed within the craniometric landmarking methods, but some bias was observed for capulometric landmarking. In conclusion, this research provides a first validation of the precision and accuracy of the automatic placement of landmarks on 3D hard- and soft-tissue surfaces and demonstrates its utilization as a convenient prerequisite for geometric morphometrics based shape analysis of the nasal complex.status: publishe

    Review of the distribution of Kaposi's sarcoma-associated herpesvirus (KSHV) in Africa in relation to the incidence of Kaposi's sarcoma

    No full text
    In the years before human immunodeficiency virus (HIV) infection, the incidence of Kaposi's sarcoma varied markedly across the African continent, and it was a disease primarily affecting men. In contrast, the evidence reviewed here shows that the causal virus-Kaposi's sarcoma associated herpesvirus (KSHV)-is prevalent in many African countries, including places where Kaposi's sarcoma was almost unknown before HIV, and that it is as common in women as in men. Therefore, the geographical distribution of Kaposi's sarcoma in Africa before the spread of HIV and its predominance as a disease affecting men are not a simple reflection of the distribution of KSHV. Since the epidemic of HIV in Africa, Kaposi's sarcoma has become relatively more frequent in women, and the incidence has increased in countries where it was previously rare, but where KSHV is prevalent, as well as in countries where it was already common. These changes point to a role for other (as yet unknown) factors in the aetiology of Kaposi's sarcoma that may have the most effect in the absence of concurrent HIV infection. (C) 2003 Cancer Research UK

    Aspergillosis

    No full text

    Allgemeine Stoffwechselmorphologie des Cytoplasmas

    No full text
    corecore