11 research outputs found

    Surface immobilization methods for aptamer diagnostic applications

    No full text
    In this review we examine various methods for the immobilization of aptamers onto different substrates that can be utilized in a diverse array of analytical formats. In most cases, covalent linking to surfaces is preferred over physisorption, which is reflected in the bulk of the reports covered within this review. Conjugation of aptamers with appropriate linkers directly to gold films or particles is discussed first, followed by methods for conjugating aptamers to functionally modified surfaces. In many aptamer-based applications, silicates and silicon oxide surfaces provide an advantage over metallic substrates, and generally require surface modification prior to covalent attachment of the aptamers. Chemical protocols for covalent attachment of aptamers to functionalized surfaces are summarized in the review, showing common pathways employed for aptamer immobilization on different surfaces. Biocoatings, such as avidin or one of its derivatives, have been shown to be highly successful for immobilizing biotin-tethered aptamers on various surfaces (e.g., gold, silicates, polymers). There are also a few examples reported of aptamer immobilization on other novel substrates, such as quantum dots, carbon nanotubes, and carbohydrates. This review covers the literature on aptamer immobilization up to March 2007, including comparison of different linkers of varying size and chemical structure, 3 versus 5 attachment, and regeneration methods of aptamers on surfaces. © 2007 Springer-Verlag

    Designing highly specific biosensing surfaces using aptamer monolayers on gold

    No full text
    To build highly specific surfaces using aptamer affinity reagents, the effects of linker and coadsorbents were investigated for maximizing target binding and specificity for aptamer-based self-assembled monolayers (SAMs) supported on gold. An aptamer that binds the protein thrombin was utilized as a model system to compare different mixed monolayer systems toward maximizing binding and selectivity to the immobilized aptamer. Important factors used to optimize binding characteristics of thrombin to the aptamer-based monolayer films include changes in design elements of the linker and different coadsorbent thiols. Binding events measured by surface plasmon resonance (SPR) and ellipsometry showed that the binding performance of the aptamer SAMs depends principally on the linker and to a lesser extent on the coadsorbent. SAMs formed with HS-(CH 2) 6-OP(O) 2O-(CH 2CH 2O) 6-TTTTT-aptamer exhibited a 4-fold increase in binding capacity versus SAMs made using HS-(CH 2) 6-TTTTT-aptamer. Furthermore, SAMs made using HS-(CH 2) 6-OP(O) 2O-(CH 2CH 2O) 6-TTTTT-aptamer showed nearly complete specificity for thrombin versus bovine serum albumin (BSA, less than 2% bound), while a SAM incorporating a random DNA fragment (HS-(CH 2) 6-OP(O) 2O-(CH 2CH 2O) 6-TTTTT-RANDOM) showed little binding of thrombin. Irrespective of the aptamer-linker system, use of HS-(CH 2) 11(OCH 2CH 2) 3OH, referred to as EG 3, as a coadsorbent enhanced binding of thrombin by approximately 2.5-fold compared to that of HS-(CH 2) 6-OH (mercaptohexanol, MCH). © 2006 American Chemical Society

    Effect of linker structure on surface density of aptamer monolayers and their corresponding protein binding efficiency

    No full text
    A systematic study is reported on the effect of linker size and its chemical composition toward ligand binding to a surface-immobilized aptamer, measured using surface plasmon resonance. The results, using thrombin as the model system, showed that as the number of thymidine (T) units in the linker increases from 0 to 20 in four separate increments (T0, T 5, T10, T20), the surface density of the aptamer decreased linearly from approximately 25 to 12 pmol·cm -2. The decrease in aptamer surface density occurred due to the increased size of the linker molecules. In addition, thrombin binding capacity was shown to increase as the linker length increased from 0 to 5 thymidine nucleotides and then decreased as the number of thymidine residues increased to 20 due to a balance between two different effects. The initial increase was due to increased access of thrombin to the aptamer as the aptamer was moved away from the surface. For linkers greater in length than T5, the overall decrease in binding capacity was primarily due to a decrease in the surface density. Incorporation of a hexa(ethylene glycol) moiety into the linker did not affect the surface density but increased the amount of thrombin bound. In addition, the attachment of the linker at the 3′- versus the 5′-end of the aptamer resulted in increased aptamer surface density. However, monolayers formed with equal surface densities showed similar amounts of thrombin binding irrespective of the point of attachment. © 2008 American Chemical Society

    Poly(methyl methacrylate) microchip affinity capillary gel electrophoresis of aptamer-protein complexes for the analysis of thrombin in plasma

    No full text
    Thrombin generation in blood serves as an important marker for various hemostasis-related diseases and conditions. Analytical techniques currently utilized for determining the thrombin potential of patients rely primarily on the enzymatic activity of thrombin. Microfluidic-based ACE using fluorescently labeled aptamers as affinity probes could provide a simple and efficient technique for the real-time analysis of thrombin levels in plasma. In this study, aptamers were used for the analysis of thrombin by affinity microchip CGE. The CGE used a poly(methyl methacrylate) (PMMA) microfluidic device for the sorting of the affinity complexes with a linear polyacrylamide (LPA) serving as the sieving matrix. Due to the fact that the assay was run under nonequilibriurn electrophoresis conditions, the presence of the sieving gel was found to stabilize the affinity complex, providing improved electrophoretic performance compared to free-solution electrophoresis. Two fluorescently labeled aptamer affinity probes, HD1 and HD22, which bind to exosites I and II, respectively, of thrombin were investigated. With an electric field strength of 300 V/cm, two well-resolved peaks corresponding to free aptamer and the thrombin-aptamer complex were obtained in less than 1 min of separation time with a run-to-run and chip-to-chip reproducibility (RSD) of migration times \u3c10% using both aptamers. HD22 affinity assays of thrombin produced baseline-resolved peaks with favorable efficiency due to its higher binding affinity, whereas HD1 assays showed poorer resolution of the free aptamer and complex peaks. HD22 was used in determining the level of thrombin in human plasma. Assays were performed directly on plasma that was diluted to 10% v/v. Thrombin was successfully analyzed by microchip CGE at a concentration level of 543.5 nM for the human plasma sample. © 2008 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim

    Advances in Microfluidic Materials, Functions, Integration, and Applications

    No full text

    Unique insight into protein-DNA interactions from single molecule atomic force microscopy

    No full text

    Aptamer-Functionalized Nanoparticles as “Smart Bombs”: The Unrealized Potential for Personalized Medicine and Targeted Cancer Treatment

    No full text

    Latest Developments in Micro Total Analysis Systems

    No full text
    corecore