5 research outputs found

    Acceptability and feasibility of a virtual community of practice to primary care professionals regarding patient empowerment : A qualitative pilot study

    Get PDF
    Background: Virtual communities of practice (vCoPs) facilitate online learning via the exchange of experiences and knowledge between interested participants. Compared to other communities, vCoPs need to overcome technological structures and specific barriers. Our objective was to pilot the acceptability and feasibility of a vCoP aimed at improving the attitudes of primary care professionals to the empowerment of patients with chronic conditions. Methods: We used a qualitative approach based on 2 focus groups: one composed of 6 general practitioners and the other of 6 practice nurses. Discussion guidelines on the topics to be investigated were provided to the moderator. Sessions were audio-recorded and transcribed verbatim. Thematic analysis was performed using the ATLAS-ti software. Results: The available operating systems and browsers and the lack of suitable spaces and time were reported as the main difficulties with the vCoP. The vCoP was perceived to be a flexible learning mode that provided up-to-date resources applicable to routine practice and offered a space for the exchange of experiences and approaches. Conclusions: The results from this pilot study show that the vCoP was considered useful for learning how to empower patients. However, while vCoPs have the potential to facilitate learning and as shown create professional awareness regarding patient empowerment, attention needs to be paid to technological and access issues and the time demands on professionals. We collected relevant inputs to improve the features, content and educational methods to be included in further vCoP implementation. Trial registration: ClinicalTrials.gov, NCT02757781. Registered on 25 April 2016

    Efficacy and safety of urinary catheters with silver alloy coating in patients with spinal cord injury: a multicentric pragmatic randomized controlled trial. The ESCALE trial

    No full text
    PubMed ID: 28578163Background Patients with spinal cord injury (SCI) who carry indwelling urinary catheters have an increased risk of urinary tract infection (UTI). Antiseptic silver alloy-coated (SAC) silicone urinary catheters prove to be a promising intervention to reduce UTIs; however, current evidence cannot be extrapolated to patients with SCI. Purpose This study aimed to assess the efficacy of SAC urinary catheters for preventing catheter-associated urinary tract infections. Design/Setting This is an open-label, multicenter (developed in Spain, Portugal, Chile, Turkey, and Italy), randomized clinical trial conducted in 14 hospitals from November 2012 to December 2015. Patient Sample Eligible patients were men or women with traumatic or medical SCI, aged ?18 years, requiring an indwelling urinary catheter for at least 7 days. Outcome Measures The primary outcome was the incidence of symptomatic UTIs. The secondary outcome included bacteremia in the urinary tract and adverse events. Materials and Methods Patients were randomized to receive a SAC urinary catheter (experimental group) or a standard catheter (control group) for at least 7 days. Data were compared using chi-squared test and also calculating the absolute risk difference with a 95% confidence interval. An adjusted analysis including different risk factors of UTI was performed. This study was mainly funded by La Marató de TV3 Foundation (grant number # 112210) and the European Clinical Research Infrastructures Network organization. The funders had no role in the interpretation or reporting of results. Results A total of 489 patients were included in the study, aged 55 years in the experimental group and aged 57 in the control group (p=.870); 72% were men; 43% were hospitalized patients, and 57% were outpatients (p=1.0). The most frequent cause of SCI was traumatic (73.75%), and the localization was mainly the cervical spine (42.74%). Most of the patients had an A score (complete spinal injury and no motor and sensory is preserved) on the ASIA scale (62.37%). The median time of urethral catheterization was 27 days in the experimental group and 28 days in the control group (p=.202). Eighteen patients (7.41%) in the experimental group and 19 in the control (7.72%) group had a symptomatic UTI (odds ratio [OR] 0.96 [0.49–1.87]). The adjusted analysis revealed no change in the results. Only three patients in the experimental group had bacteremia within the urinary tract. The experimental group presented more adverse events related to the use of a catheter than the control group (OR 0.03 [0.00–0.06]). Conclusions The results of this study do not support the routine use of indwelling antiseptic SAC silicone urinary catheters in patients with SCI. However, UTIs associated to long-term urinary catheter use remain a challenge and further investigations are still needed. © 2017 Elsevier Inc.Fundació la Marató de TV3: # 112210 European Social Fund, ESF Instituto de Salud Carlos III, ISCIIIThe authors thank Mr. Ignacio Araya, who participated in the protocol development. This trial was funded by La Marató de TV3 Foundation , grant number # 112210 and the European Clinical Research Infrastructures Network (ECRIN, www.ecrin.org ). ECRIN reviewed the protocol, recruited Turkey and European centers, and submitted the clinical trial to the Ethics Committee (except in Spain) and, with these actions, partially supported the clinical trial. Bactiguard provided the study catheters with a 50% discount rate. This article has been written without financial support. Dr. María José Martínez-Zapata was funded by a Miguel Servet research contract from the Instituto de Salud Carlos III and the European Social Fund (Project no. CP15/00116 ). -

    International Nosocomial Infection Control Consortium report, data summary of 50 countries for 2010-2015: Device-associated module

    No full text
    •We report INICC device-associated module data of 50 countries from 2010-2015.•We collected prospective data from 861,284 patients in 703 ICUs for 3,506,562 days.•DA-HAI rates and bacterial resistance were higher in the INICC ICUs than in CDC-NHSN's.•Device utilization ratio in the INICC ICUs was similar to CDC-NHSN's. Background: We report the results of International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2010-December 2015 in 703 intensive care units (ICUs) in Latin America, Europe, Eastern Mediterranean, Southeast Asia, and Western Pacific. Methods: During the 6-year study period, using Centers for Disease Control and Prevention National Healthcare Safety Network (CDC-NHSN) definitions for device-associated health care-associated infection (DA-HAI), we collected prospective data from 861,284 patients hospitalized in INICC hospital ICUs for an aggregate of 3,506,562 days. Results: Although device use in INICC ICUs was similar to that reported from CDC-NHSN ICUs, DA-HAI rates were higher in the INICC ICUs: in the INICC medical-surgical ICUs, the pooled rate of central line-associated bloodstream infection, 4.1 per 1,000 central line-days, was nearly 5-fold higher than the 0.8 per 1,000 central line-days reported from comparable US ICUs, the overall rate of ventilator-associated pneumonia was also higher, 13.1 versus 0.9 per 1,000 ventilator-days, as was the rate of catheter-associated urinary tract infection, 5.07 versus 1.7 per 1,000 catheter-days. From blood cultures samples, frequencies of resistance of Pseudomonas isolates to amikacin (29.87% vs 10%) and to imipenem (44.3% vs 26.1%), and of Klebsiella pneumoniae isolates to ceftazidime (73.2% vs 28.8%) and to imipenem (43.27% vs 12.8%) were also higher in the INICC ICUs compared with CDC-NHSN ICUs. Conclusions: Although DA-HAIs in INICC ICU patients continue to be higher than the rates reported in CDC-NSHN ICUs representing the developed world, we have observed a significant trend toward the reduction of DA-HAI rates in INICC ICUs as shown in each international report. It is INICC's main goal to continue facilitating education, training, and basic and cost-effective tools and resources, such as standardized forms and an online platform, to tackle this problem effectively and systematically
    corecore