18 research outputs found

    Integration of micro-gravity and geodetic data to constrain shallow system mass changes at Krafla Volcano, N Iceland

    Get PDF
    New and previously published micro-gravity data are combined with InSAR data, precise levelling and GPS measurements to produce a model for the processes operating at Krafla volcano, 20 years after its most recent eruption. The data have been divided into two periods: from 1990 to 1995 and from 1996 to 2003 and show that the rate of deflation at Krafla is decaying exponentially. The net micro-gravity change at the centre of the caldera is shown, using the measured Free Air Gradient, to be -85 μGal for the first and -100 μGal for the second period. After consideration of the effects of water extraction by the geothermal power station within the caldera, the net gravity decreases are -73 ± 17 μGal for the first and -65 ± 17 μGal for the second period. These decreases are interpreted in terms of magma drainage. Following a Mogi point source model we calculate the mass decrease to be ~2 x 1010 kg/yr reflecting a drainage rate of ~0.23 m3/s, similar to the ~0.13 m3/s drainage rate previously found at Askja volcano, N-Iceland. Based on the evidence for deeper magma reservoirs and the similarity between the two volcanic systems, we suggest a pressure-link between Askja and Krafla at deeper levels (at the lower crust or the crust-mantle boundary). After the Krafla fires, co-rifting pressure decrease of a deep source at Krafla stimulated the subsequent inflow of magma, eventually affecting conditions along the plate boundary in N-Iceland, as far away as Askja. We anticipate that the pressure of the deeper reservoir at Krafla will reach a critical value and eventually magma will rise from there to the shallow magma chamber, possibly initiating a new rifting episode. We have demonstrated that by examining micro-gravity and geodetic data, our knowledge of active volcanic systems can be significantly improved

    Using dissolved H<sub>2</sub>O in rhyolitic glasses to estimate palaeo-ice thickness during a subglacial eruption at Bláhnúkur(Torfajökull, Iceland)

    Get PDF
    The last decade has seen the refinement of a technique for reconstructing palaeo-ice thicknesses based on using the retained H2O and CO2 content in glassy eruptive deposits to infer quenching pressures and therefore ice thicknesses. The method is here applied to Bláhnúkur, a subglacially erupted rhyolitic edifice in Iceland. A decrease in water content from ~0.7 wt.% at the base to ~0.3 wt.% at the top of the edifice suggests that the ice was 400 m thick at the time of the eruption. As Bláhnúkur rises 350 m above the surrounding terrain, this implies that the eruption occurred entirely within ice, which corroborates evidence obtained from earlier lithofacies studies. This paper presents the largest data set (40 samples) so far obtained for the retained volatile contents of deposits from a subglacial eruption. An important consequence is that it enables subtle but significant variations in water content to become evident. In particular, there are anomalous samples which are either water-rich (up to 1 wt.%) or water-poor (~0.2 wt.%), with the former being interpreted as forming intrusively within hyaloclastite and the latter representing batches of magma that were volatile-poor prior to eruption. The large data set also provides further insights into the strengths and weaknesses of using volatiles to infer palaeo-ice thicknesses and highlights many of the uncertainties involved. By using examples from Bláhnúkur, the quantitative use of this technique is evaluated. However, the relative pressure conditions which have shed light on Bláhnúkur’s eruption mechanisms and syn-eruptive glacier response show that, despite uncertainties in absolute values, the volatile approach can provide useful insight into the mechanisms of subglacial rhyolitic eruptions, which have never been observed

    The flexural or rotational stiffness of testing machines

    No full text

    Clinical features in secondary and cryptogenic organising pneumonia

    No full text
    SETTING: The clinical differences between cryptogenic organising pneumonia (COP) and secondary organising pneumonia (OP) have not been studied well. OBJECTIVE: To compare clinical features in COP and secondary OP. DESIGN: Causes, clinical features, treatment, radiographic studies and pathology were studied. RESULTS: After re-evaluation, 104 patients fulfilled the diagnostic criteria, 58 for COP and 46 for secondary OP. The mean age was 68 years. Most of the patients were smokers (79/104). Infections were the most common causes of secondary OP (21/46). Cough was the most common symptom and crackles the most common sign. Crackles were more common in patients with secondary OP (P = 0.02). Transbronchial biopsy was the diagnostic test in 81/104 cases. Most patients had lowered partial oxygen pressure (PO(2)) and mildly restrictive spirometry, with no differences between the two groups. Radiographic features were similar. Corticosteroids were the treatment in 70% of the patients, but 27% received no pharmacological treatment. The average initial dose of steroids was 42 mg prednisolone, and was similar for both groups. Relapses were seen in 20% of cases, with no difference between the two groups. CONCLUSION: There were no major differences in clinical features of COP and secondary OP, except that crackles were more common in secondary OP
    corecore