122 research outputs found

    Reaction of rat connective tissue to mineral trioxide aggregate and diaket

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this study was to compare the reaction of rat connective tissue to two root-end filling materials: white Mineral Trioxide Aggregate (WMTA) and Diaket.</p> <p>Methods</p> <p>Each of the materials was placed in dentine tubes and implanted subcutaneously in the dorsal connective tissue of 21 Wistar albino rats. Tissue biopsies were collected 7, 30, and 60 days after the implantation procedure. The specimens were processed and stained with hematoxylin and eosin and examined microscopically. After determining inflammatory cell numbers in sections from each specimen, inflammatory reaction scores were defined as follows: 0; no or few inflammatory cells (no reaction), 1; less than 25 cells (mild reaction), 2; 25 to 125 cells, (moderate reaction), and 3; 125 or more cells (severe reaction). Statistical analysis was performed using the Kruskal-Wallis and Mann-Whitney tests.</p> <p>Results</p> <p>There were statistically significant differences in the median inflammatory cell numbers throughout the three test periods, with the most severe degree of inflammation observed at the one-week period. Few cases of necrosis were observed with WMTA. Diaket exhibited the most severe degree of inflammation and necrosis. After 30 days, both materials provoked moderate inflammatory reaction. The eight-week period showed the least severe degree of inflammation in all groups.</p> <p>Conclusions</p> <p>It was concluded that WMTA exhibits a more favourable tissue response compared with Diaket which induced more severe inflammatory reaction than WMTA and the control.</p

    An evaluation of the effect of non-setting calcium hydroxide on human dentine: a pilot study.

    Get PDF
    AIM: To evaluate the effect of non-setting calcium hydroxide (NSCH) on the hardness and elastic modulus of dentine from extracted permanent premolar human teeth. METHODS: 30 freshly extracted single rooted human premolar teeth were decoronated and the roots then sectioned longitudinally into equal halves. In the experimental group a thin layer of NSCH was applied whilst the control group had no medicament. After 1, 3 and 6 months, nanoindentation was used to assess dentine hardness and the modulus of elasticity. Scanning Electron Microscopy (SEM) was used to visualize the depth of penetration of NSCH into the dentinal tubules. RESULTS: SEM images showed that there were no structural changes in the dentine slabs that had NSCH application after 1, 3 or even 6 months. However, penetration of NSCH into the dentine tubules was seen at both 3 and 6 months with a significant reduction in the hardness of dentine observed at 3 (p<0.02) and 6 months (p<0.01). The modulus of elasticity was significantly lower (p<0.01) at 6 months. CONCLUSION: It appears that there is a significant reduction in the hardness of dentine with increasing periods of calcium hydroxide application. Prolonged application of NSCH could have a detrimental effect on dentine, making the dentine more prone to fracture

    In vitro analysis of the cytotoxicity and the antimicrobial effect of four endodontic sealers

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>The aim of this study was to investigate <it>in vitro </it>the cytotoxicity and antibacterial properties of four different endodontic sealers using human periodontal ligament fibroblast cell proliferation and visual analysis of growth inhibition.</p> <p>Methods</p> <p>A silicone (GuttaFlow), silicate (EndoSequence BC), zinc oxide eugenol (Pulp Canal Sealer EWT) and epoxy resin (AH Plus Jet) based sealer were incubated with PDL fibroblasts (10<sup>4 </sup>cells/ml, n = 6) up to 96 h. Cell proliferation (RFU) was determined by means of the Alamar Blue assay. Cell growth and morphology was visualized by means of fluorescent dyes. Possible antibacterial properties of the different sealers were visualized by means of SEM (<it>Enterococcus faecalis; Parvimonas micra</it>).</p> <p>Results</p> <p>Fibroblast proliferation depended on sealer and cultivation time. After 72 and 96 h GuttaFlow and EndoSequence BC showed relatively non-cytotoxic reactions, while Pulp Canal Sealer EWT and AH Plus Jet caused a significant decrease of cell proliferation (p < 0.001). Visualization of cell growth and morphology with various fluorescent dyes supplemented the results. No antibacterial effect of EndoSequence BC to <it>P. micra </it>was found, whereas GuttaFlow showed a weak, Pulp Canal Sealer EWT and AH Plus Jet extensive growth inhibition. Also, no antibacterial effect of GuttaFlow, EndoSequence BC or AH Plus Jet to <it>E. faecalis </it>could be detected.</p> <p>Conclusions</p> <p>These <it>in vitro </it>findings reveal that GuttaFlow and EndoSequence BC can be considered as biocompatible sealing materials. However, prior to their clinical employment, studies regarding their sealing properties also need to be considered.</p
    • …
    corecore