11 research outputs found

    Outcome of Two Corneal Collagen Crosslinking Methods in Bullous Keratopathy due to Fuchs’ Endothelial Dystrophy

    No full text
    Four eyes of 2 patients with corneal edema due to Fuchs’ endothelial dystrophy were treated with CXL using the standard protocol. Since no improvement in visual acuity, corneal clarity, thickness, or pain sensation was evident in any eye at month 12, 2 eyes of the 2 patients were retreated, this time, following intraoperative corneal dehydration with glycerol 70% drops. This retreatment also failed to produce any significant effect on vision, corneal clarity, thickness, or pain in either eye. Collagen crosslinking with the current protocols may not be effective in the management of eyes with corneal edema due to Fuchs’ endothelial dystrophy. Further studies are required to establish the efficacy of CXL and optimize the technique and/or dehydration method utilized in these cases

    Clinical Performance of Samfilcon A Contact Lenses in Intensive Digital Device Users: A Multicenter, Prospective Clinical Study

    No full text
    Introduction To evaluate patient satisfaction with samfilcon A contact lenses (CLs) in intensive digital device users with myopia and to compare patient satisfaction with samfilcon A lenses to prior experience with senofilcon A or lotrafilcon B CLs. Methods This was a comparative, prospective, national study conducted at 14 centers in Turkey. Subjects were adults aged 18 and 45 years with myopia (range -0.25 D to -6.00 D) who spend a minimum of 3 hours viewing digital devices (e.g., computer, smartphone). A subgroup of patients were habitual lens wearers (senofilcon A or lotrafilcon B lens wear for at least 6 months prior to enrollment). The primary assessment was patient satisfaction with samfilcon A lenses (0-100 Likert scale). Secondary assessments included patient satisfaction with samfilcon A lenses compared to patients' habitual lenses, investigator satisfaction with samfilcon A lenses and investigator-evaluated slit lamp examination findings. Results Samfilcon A lenses were given high overall ratings from both patients and investigators, with a low incidence of ocular symptoms. Overall, patients were highly satisfied with samfilcon A lenses for comfort, vision and overall performance, and stated that they would consider wearing these lenses in the future. Among habitual senofilcon A or lotrafilcon B lens wearers, samfilcon A lenses were rated significantly better than the habitual lenses in regard to comfort, vision and overall performance. Investigator assessments were also highly favorable, both at initial fit and after 4 weeks of follow-up, with no significant findings noted on slit lamp examination. Conclusion Samfilcon A lenses were rated highly by investigators in regard to fit, handling and slit lamp findings, and by novice and habitual lens wearers in regard to comfort, vision and overall performance. These results support the use of samfilcon A lenses among digital device users who seek day-long comfort and good visual acuity

    TFOS lifestyle: Impact of contact lenses on the ocular surface

    No full text
    Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviours (e.g., using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic has impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers

    Changes in Intraocular Pressure and Anterior Segment Morphometry after Uneventful Phacoemulsification Cataract Surgery

    Get PDF
    Purpose To study changes in anterior segment morphometry after uneventful phacoemulsification cataract surgery, and to investigate whether there is a relationship between any observed changes and intraocular pressure (IOP) reduction after the procedure. Methods The anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), central corneal thickness (CCT), and IOP were measured in 101 non-glaucomatous eyes before and after uneventful phacoemulsification cataract surgery. Results After cataract surgery, the mean ACD, ACV, and ACA values increased by 1.08mm, 54.4mm3, and 13.11, respectively, and the mean IOP (corrected for CCT) decreased by 3.2mmHg. The predictive value of a previously described index (preoperative ACD/preoperative IOP (corrected for CCT) or CPD ratio) for IOP (corrected for CCT) reduction after cataract surgery was confirmed, reflected in an r2 value of 23.3% between these two parameters (Po0.001). Other indices predictive of IOP reduction after cataract surgery were also identified, including preoperative IOP/preoperative ACV and preoperative IOP/preoperative ACA, reflected in r2 values of 13.7 and 13.7%, respectively (Po0.001 and Po0.001, respectively). Conclusions Our study confirms the predictive value of the CPD ratio for IOP reduction after cataract surgery, and may contribute to the decision-making process in patients with glaucoma or ocular hypertension. Furthermore, two novel indices of preoperative parameters that are predictive for IOP reduction after cataract surgery were identified, and enhance our understanding of the mechanisms underlying IOP changes after this procedure
    corecore